Device tester ST 725 battery/mains operated - 1 pcBenning
Device tester ST 725 battery/mains operated - 1 pc
Benning
Fixed price plus VAT
€985
Condition
New
Location
Titisee-Neustadt 

Basic data
- Machine type:
- Device tester ST 725 battery/mains operated - 1 pc
- Manufacturer:
- Benning
- Condition:
- new
Price & Location
Fixed price plus VAT
€985
- Seller location:
- Feldbergstraße 37, 79822 Titisee-Neustadt, Germany

Call
Details about the offer
- Listing ID:
- A231-25261
- Reference number:
- 4000828856
- Update:
- 21.10.2026
Description
Device Tester ST 725, battery/mains operation, L270 x W115 x H55 mm, BENNING
· Suitable for electrical engineering, industry, maintenance, service, and municipalities (easy to use, for battery-powered and mains-powered tests). Application areas: testing devices with mains voltage-dependent switching elements/power supplies/relays, such as electronically controlled devices/tools.
· Devices in information and communication technology, as well as devices that can only be fully tested with mains voltage, according to VDE 0701-0702, DGUV regulation 3, ÖVE/ÖNORM E 8701, NEN 3140.
· Measurement value memory for 999 test objects, readable via Micro-USB interface.
· Download software for creating test reports in MS Excel.
· Direct test report creation via serial interface and optional printer BENNING PT 1.
· Integrated real-time clock for storing measurement values with test date.
Hjdpfx Ao Ab Dkqoi Tew
· Fast (testing within seconds), complete (device tester and RCD tester in one device), unique (testing of 1- and 3-phase devices under operating conditions).
· Automatic test sequence with pass/fail indication for devices of class I, II (III) and conductor test.
· Active testing of 3-phase devices under operating conditions (optional measuring adapters).
· Limit values according to VDE standard preset.
· Battery capacity for 2500 test objects.
· Weight: 950 g.
Measurements: protective conductor resistance (200 mA test current with polarity reversal), insulation resistance (250 V/500 V test voltage), testing of 30 mA RCD/PRCD protective devices (tripping time at 1 x and 5 x rated current), voltage at external protective contact socket.
Mains operation: protective conductor/touch current via differential current/direct measurement method with automatic mains polarity reversal.
Battery operation: protective conductor/touch current via equivalent leakage current method.
· Other technical specifications: width: 115 mm, length: 270 mm, height: 55 mm.
Model: ST 725
The listing was translated automatically. Translation errors are possible.
· Suitable for electrical engineering, industry, maintenance, service, and municipalities (easy to use, for battery-powered and mains-powered tests). Application areas: testing devices with mains voltage-dependent switching elements/power supplies/relays, such as electronically controlled devices/tools.
· Devices in information and communication technology, as well as devices that can only be fully tested with mains voltage, according to VDE 0701-0702, DGUV regulation 3, ÖVE/ÖNORM E 8701, NEN 3140.
· Measurement value memory for 999 test objects, readable via Micro-USB interface.
· Download software for creating test reports in MS Excel.
· Direct test report creation via serial interface and optional printer BENNING PT 1.
· Integrated real-time clock for storing measurement values with test date.
Hjdpfx Ao Ab Dkqoi Tew
· Fast (testing within seconds), complete (device tester and RCD tester in one device), unique (testing of 1- and 3-phase devices under operating conditions).
· Automatic test sequence with pass/fail indication for devices of class I, II (III) and conductor test.
· Active testing of 3-phase devices under operating conditions (optional measuring adapters).
· Limit values according to VDE standard preset.
· Battery capacity for 2500 test objects.
· Weight: 950 g.
Measurements: protective conductor resistance (200 mA test current with polarity reversal), insulation resistance (250 V/500 V test voltage), testing of 30 mA RCD/PRCD protective devices (tripping time at 1 x and 5 x rated current), voltage at external protective contact socket.
Mains operation: protective conductor/touch current via differential current/direct measurement method with automatic mains polarity reversal.
Battery operation: protective conductor/touch current via equivalent leakage current method.
· Other technical specifications: width: 115 mm, length: 270 mm, height: 55 mm.
Model: ST 725
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2026
14,349 listings online
Send inquiry
Telephone & Fax
+49 7651 ... show
These listings may also fit your interest.
Success:
Your message has been sent.
Listing
Titisee-Neustadt
7,949 km
Installation testing device IT - 1 unit
Benning
Benning
Success:
Your message has been sent.
Listing
Titisee-Neustadt
7,949 km
AC/DC current clamp adapter CC - 1 piece
Benning
Benning
Success:
Your message has been sent.
Listing
Titisee-Neustadt
7,949 km
Earthing set, 5-piece, for installation testing – 1 unit
Benning
Benning
Success:
Your message has been sent.
Listing
Titisee-Neustadt
7,949 km
Measuring adapter for 3-phase consumers - 1 piece
Benning
Benning
Success:
Your message has been sent.
Listing
Titisee-Neustadt
7,949 km
Measuring adapter for 3-phase consumers - 1 piece
Benning
Benning
Success:
Your message has been sent.
Listing
Titisee-Neustadt
7,949 km
Insulation/Resistance Measuring Device - 1 pc
Benning
Benning
Success:
Your message has been sent.
Listing
Titisee-Neustadt
7,949 km
Device tester ST 710, 2500 test specimens/with – 1 unit
Benning
Benning
Success:
Your message has been sent.
Listing
Titisee-Neustadt
7,949 km
Multimeter MM 5-2, 0.1 mV–600 V – 1 piece
Benning
Benning
Success:
Your message has been sent.
Listing
Titisee-Neustadt
7,949 km
Multimeter MM 2 0.1 mV-750 – 1 pc
Benning
Benning
Success:
Your message has been sent.
Listing
Titisee-Neustadt
7,949 km
Voltage/Continuity Tester - 1 pc
Benning
Benning
Your listing has been deleted successfully
An error has occurred












































