Description
Heraeus Vötsch
Type: VTS 7018-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ± 0.1 to ± 0.5 K
Temperature deviation (spatial): ± 0.5 to ± 2.0 K
Temperature change rate (cooling): 7.5 K/min
Temperature change rate (heating): 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Observation window:
Width 300 mm x Height 540 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10.5 kW, Rated current: 22 A
Fuse (customer-side): 32 A, time-delay
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side access: 50 cm / 125 cm
Chamber is water-cooled
Refrigerant: R 404A and R 23
Weight: approx. 460 kg
Gsdpfx Aozdtdheqgeuh
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
The listing was translated automatically. Translation errors are possible.
Type: VTS 7018-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ± 0.1 to ± 0.5 K
Temperature deviation (spatial): ± 0.5 to ± 2.0 K
Temperature change rate (cooling): 7.5 K/min
Temperature change rate (heating): 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Observation window:
Width 300 mm x Height 540 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10.5 kW, Rated current: 22 A
Fuse (customer-side): 32 A, time-delay
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side access: 50 cm / 125 cm
Chamber is water-cooled
Refrigerant: R 404A and R 23
Weight: approx. 460 kg
Gsdpfx Aozdtdheqgeuh
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Heraeus Vötsch temperature test chamber, 190 liters, temperature range -70°C to +180°C, model VTS 70
Heraeus VötschVTS 7018-5
Heraeus VötschVTS 7018-5
Your listing has been deleted successfully
An error has occurred