Measuring systemKeyence
IM-6225
Measuring system
Keyence
IM-6225
Year of construction
2015
Condition
Used
Location
Hoogeveen 

Show images
Show map
Machine data
- Machine type:
- Measuring system
- Manufacturer:
- Keyence
- Model:
- IM-6225
- Year of construction:
- 2015
- Condition:
- used
- Functionality:
- fully functional
Price & Location
- Location:
- Edisonstraat 14, 7903AN Hoogeveen, Nederland

Call
Technical details
- Input voltage:
- 230 V
- Overall weight:
- 31 kg
- Workpiece weight (max.):
- 2 kg
- Travel distance X-axis:
- 100 mm
- Travel distance Z-axis:
- 30 mm
- Power:
- 0.3 kW (0.41 HP)
- Equipment:
- documentation/manual, type plate available
Details about the offer
- Listing ID:
- A208-97622
- Update:
- 09.01.2026
Description
Model IM-6225
Type Measurement Unit
Image Sensor 1" 6.6 megapixel monochrome CMOS
Display 10.4" LCD monitor (XGA: 1024 x 768), external monitor connectable (clone output)
Light-collecting Lens Dual telecentric lens
Image Measurement Field of View Wide field: ø100×L200mm High Accuracy: □25×L125mm
Minimum Display Unit 0.1 µm
Repeatability Without Stage Movement Wide field: ±1µm High Accuracy: ±0.5µm
With Stage Movement Wide field: ±2µm High Accuracy: ±1.5µm
Measurement Accuracy (±2σ) Without Clamping Wide field: ±5µm*1 High Accuracy: ±2µm*2
Height Measurement Measurement Area -
External Remote Input Non-voltage input (contact or solid-state)
External Output OK/NG/FAIL/MEAS. Relay output / Max. load: 24 VDC 0.5A / ON resistance: 50 mΩ or less
Interface LAN RJ-45 (10BASE-T / 100BASE-TX / 1000BASE-T)
USB 2.0 Type A 6 ports (front: 2, rear: 4)
Storage Hard Disk Drive 250 GB
Illumination System Transmissive Telecentric transmissive illumination (green LED)
X Axis Support Travel Range 100 mm (motorized)
Fpjdpfx Agex S D I Aemjb
Z Axis Support 30 mm (motorized)
Max. Load 2 kg
Power Supply Voltage 100 to 240 VAC 50 / 60 Hz
Power Consumption 310 VA max.
Environmental Resistance Ambient Temperature +10 to +35 °C
Ambient Humidity 20 to 80 % RH (non-condensing)
Weight Approx. 31 kg
The listing was translated automatically. Translation errors are possible.
Type Measurement Unit
Image Sensor 1" 6.6 megapixel monochrome CMOS
Display 10.4" LCD monitor (XGA: 1024 x 768), external monitor connectable (clone output)
Light-collecting Lens Dual telecentric lens
Image Measurement Field of View Wide field: ø100×L200mm High Accuracy: □25×L125mm
Minimum Display Unit 0.1 µm
Repeatability Without Stage Movement Wide field: ±1µm High Accuracy: ±0.5µm
With Stage Movement Wide field: ±2µm High Accuracy: ±1.5µm
Measurement Accuracy (±2σ) Without Clamping Wide field: ±5µm*1 High Accuracy: ±2µm*2
Height Measurement Measurement Area -
External Remote Input Non-voltage input (contact or solid-state)
External Output OK/NG/FAIL/MEAS. Relay output / Max. load: 24 VDC 0.5A / ON resistance: 50 mΩ or less
Interface LAN RJ-45 (10BASE-T / 100BASE-TX / 1000BASE-T)
USB 2.0 Type A 6 ports (front: 2, rear: 4)
Storage Hard Disk Drive 250 GB
Illumination System Transmissive Telecentric transmissive illumination (green LED)
X Axis Support Travel Range 100 mm (motorized)
Fpjdpfx Agex S D I Aemjb
Z Axis Support 30 mm (motorized)
Max. Load 2 kg
Power Supply Voltage 100 to 240 VAC 50 / 60 Hz
Power Consumption 310 VA max.
Environmental Resistance Ambient Temperature +10 to +35 °C
Ambient Humidity 20 to 80 % RH (non-condensing)
Weight Approx. 31 kg