Emergency generatorNotstromaggregat 2000 KVA MTU
16v396
Emergency generator
Notstromaggregat 2000 KVA MTU
16v396
Year of construction
1996
Condition
Used
Location
Königswinter 

Show images
Show map
Machine data
- Machine type:
- Emergency generator
- Manufacturer:
- Notstromaggregat 2000 KVA MTU
- Model:
- 16v396
- Year of construction:
- 1996
- Condition:
- excellent (used)
- Functionality:
- fully functional
- Operating hours:
- 250 h
Price & Location
- Location:
- Hauptstraße 371, 53639 Königswinter, Deutschland

Call
Details about the offer
- Listing ID:
- A189-05271
- Update:
- 08.04.2025
Description
We have a 2000 KVA container generator for sale.
Optionally 400/230 V (50 Hz)
or 10 kV (+/- 5%) (50 Hz)
Fully installed in two soundproof 40' HC containers.
Suitable and intended for multi-layer installation.
Dimensions: (L x W x H) 12020 x 2500 x 5800 mm
Weight: approx. 33 t + 11 t
Engine: MTU 16v396 TB 34D
Generator: A.v. Kaick DIDBN 130/125 h/4
2000 KVA Generator
Engine and generator completely mounted on a base frame and connected via a flexible coupling.
Cooling system:
Separate table cooler installed as a dual-circuit cooler in the upper container, including temperature control, connecting lines (stainless steel cooling water lines with shut-off valves for each line), circulation pumps, control valves, etc. for safe operation.
Tank system:
4000-liter tank system installed in the upper container, including system-specific accessories and complete piping.
Air supply and exhaust system:
Soundproof baffles within the air supply and exhaust chambers in the container.
Air supply and exhaust openings each equipped with appropriate weather protection grilles, motor-operated blinds in the container that open automatically when the generator is in operation.
Exhaust system:
Dedpfx Ahewa Tg Do Sjul
Insulated exhaust ducts within the container lead vertically from the container via silencers through the upper container, discharging the exhaust gases through the container roof.
Switchgear:
Medium/low-voltage switchgear for fully automatic emergency power operation!!!
Optionally 400/230 V or 10 kV (+/-5%)
Fully automatic machine monitoring with control for power failure detection, automatic start-up, and emergency power takeover. Upon power recovery, the system automatically switches back to the mains supply.
In the low-voltage range, parallel operation with the mains/resynchronization is possible.
Control for external mains switch - optionally 10 kV or 400/230 V
Low-voltage switchgear equipped with: 3200 A generator switch (400/230 V)
Medium-voltage switchgear equipped with: 115 A generator switch (10 kV)
Technical data of the type-tested medium-voltage switchgear
Panel type: ZS8
Rated voltage: 12 kV
Operating voltage: 10 kV
etc.
The listing was translated automatically. Translation errors are possible.
Optionally 400/230 V (50 Hz)
or 10 kV (+/- 5%) (50 Hz)
Fully installed in two soundproof 40' HC containers.
Suitable and intended for multi-layer installation.
Dimensions: (L x W x H) 12020 x 2500 x 5800 mm
Weight: approx. 33 t + 11 t
Engine: MTU 16v396 TB 34D
Generator: A.v. Kaick DIDBN 130/125 h/4
2000 KVA Generator
Engine and generator completely mounted on a base frame and connected via a flexible coupling.
Cooling system:
Separate table cooler installed as a dual-circuit cooler in the upper container, including temperature control, connecting lines (stainless steel cooling water lines with shut-off valves for each line), circulation pumps, control valves, etc. for safe operation.
Tank system:
4000-liter tank system installed in the upper container, including system-specific accessories and complete piping.
Air supply and exhaust system:
Soundproof baffles within the air supply and exhaust chambers in the container.
Air supply and exhaust openings each equipped with appropriate weather protection grilles, motor-operated blinds in the container that open automatically when the generator is in operation.
Exhaust system:
Dedpfx Ahewa Tg Do Sjul
Insulated exhaust ducts within the container lead vertically from the container via silencers through the upper container, discharging the exhaust gases through the container roof.
Switchgear:
Medium/low-voltage switchgear for fully automatic emergency power operation!!!
Optionally 400/230 V or 10 kV (+/-5%)
Fully automatic machine monitoring with control for power failure detection, automatic start-up, and emergency power takeover. Upon power recovery, the system automatically switches back to the mains supply.
In the low-voltage range, parallel operation with the mains/resynchronization is possible.
Control for external mains switch - optionally 10 kV or 400/230 V
Low-voltage switchgear equipped with: 3200 A generator switch (400/230 V)
Medium-voltage switchgear equipped with: 115 A generator switch (10 kV)
Technical data of the type-tested medium-voltage switchgear
Panel type: ZS8
Rated voltage: 12 kV
Operating voltage: 10 kV
etc.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2021
Send inquiry
Telephone & Fax
+49 178 6... show
Your listing has been deleted successfully
An error has occurred