SICK S30B-3011BA Safety Laser Scanner Safety Scanner Laser Scanner S300Sick
S30B-3011BA
SICK S30B-3011BA Safety Laser Scanner Safety Scanner Laser Scanner S300
Sick
S30B-3011BA
ONO plus VAT
€1,536
Year of construction
2022
Condition
New
Location
Borken 

Basic data
Price & Location
ONO plus VAT
€1,536
- Location:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Call
Details about the offer
- Listing ID:
- A131-10761
- Reference number:
- 32738
- Update:
- 07.10.2026
Description
SICK S30B-3011BA Safety Laser Scanner
Features
Design: Sensor without system connector
Application area: Indoor
Protective field range: 3 m
Warning field range: 8 m (at 15% remission)
Distance measuring range: 30 m
Type of field set: Triple field sets
Number of field sets: 1
Number of fields: 3
Number of monitored cases: 1
Scanning angle: 270°
Resolution (configurable): 30 mm, 40 mm, 50 mm, 70 mm, 150 mm
Angular resolution: 0.5°
Response time: 80 ms 1)
Protective field offset: 100 mm
Number of multiple evaluations: 2 ... 16, configurable
Delay of automatic reset: 2 s ... 60 s, configurable
Safety-related parameters
Type: Type 3 (IEC 61496)
Safety Integrity Level: SIL2 (IEC 61508)
Category: Category 3 (EN ISO 13849)
Performance Level: PL d (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour): 8.0 x 10-8
TM (service life): 20 years (EN ISO 13849)
Function
Restart inhibit: ✔
Safety control (EDM): ✔
Multiple evaluation: ✔
Contour as reference: ✔
Integrated configuration memory: ✔
Measurement data output: Via RS-422
Secure SICK device communication via EFI: ✔
Connection type
Connection type: System connector with or without connection cable
Universal I/Os: 5 1)
Inputs:
Safety control (EDM): 1 2)
Reset/Restart: 1 2)
Stand-by: 1
Outputs:
OSSD pairs: 1
Signal outputs: 3 3)
Type of configuration: PC with CDS (Configuration and Diagnostic Software)
Configuration and diagnostic interface: RS-232
Transmission rate: 38.4 kBaud
Data interface: RS-422
Transmission rate: ≤ 500 kBaud
Secure SICK device communication via EFI:
Transmission rate: ≤ 500 kBaud
Cable length: ≤ 50 m
Conductor cross-section: 0.22 mm²
1) Freely programmable, e.g. safety control input, reset input, contamination warning, reset required.
2) Availability depends on the configuration of the universal I/Os.
Gjdpfxspudtls Afuobu
3) Freely programmable, e.g. warning field, contamination, reset required.
Protection class: III (EN 50178)
EN 60950
Supply voltage Uv: 24 V DC (16.8 V DC ... 30 V DC)
Current consumption ≤ 0.33 A 1)
≤ 1.7 A 2)
Outputs:
Safety outputs (OSSDs): 2 x 250 mA
Signal outputs: 3 x 100 mA 3)
1) At 24 V DC without output load.
2) At 24 V DC with maximum output load.
3) Freely programmable, e.g. warning field, contamination, reset required.
Item condition: new, from stock clearance (without original packaging)
Year of manufacture: 2022
You can find more scanners - new and used - in our shop!
International shipping costs on request!
The listing was translated automatically. Translation errors are possible.
Features
Design: Sensor without system connector
Application area: Indoor
Protective field range: 3 m
Warning field range: 8 m (at 15% remission)
Distance measuring range: 30 m
Type of field set: Triple field sets
Number of field sets: 1
Number of fields: 3
Number of monitored cases: 1
Scanning angle: 270°
Resolution (configurable): 30 mm, 40 mm, 50 mm, 70 mm, 150 mm
Angular resolution: 0.5°
Response time: 80 ms 1)
Protective field offset: 100 mm
Number of multiple evaluations: 2 ... 16, configurable
Delay of automatic reset: 2 s ... 60 s, configurable
Safety-related parameters
Type: Type 3 (IEC 61496)
Safety Integrity Level: SIL2 (IEC 61508)
Category: Category 3 (EN ISO 13849)
Performance Level: PL d (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour): 8.0 x 10-8
TM (service life): 20 years (EN ISO 13849)
Function
Restart inhibit: ✔
Safety control (EDM): ✔
Multiple evaluation: ✔
Contour as reference: ✔
Integrated configuration memory: ✔
Measurement data output: Via RS-422
Secure SICK device communication via EFI: ✔
Connection type
Connection type: System connector with or without connection cable
Universal I/Os: 5 1)
Inputs:
Safety control (EDM): 1 2)
Reset/Restart: 1 2)
Stand-by: 1
Outputs:
OSSD pairs: 1
Signal outputs: 3 3)
Type of configuration: PC with CDS (Configuration and Diagnostic Software)
Configuration and diagnostic interface: RS-232
Transmission rate: 38.4 kBaud
Data interface: RS-422
Transmission rate: ≤ 500 kBaud
Secure SICK device communication via EFI:
Transmission rate: ≤ 500 kBaud
Cable length: ≤ 50 m
Conductor cross-section: 0.22 mm²
1) Freely programmable, e.g. safety control input, reset input, contamination warning, reset required.
2) Availability depends on the configuration of the universal I/Os.
Gjdpfxspudtls Afuobu
3) Freely programmable, e.g. warning field, contamination, reset required.
Protection class: III (EN 50178)
EN 60950
Supply voltage Uv: 24 V DC (16.8 V DC ... 30 V DC)
Current consumption ≤ 0.33 A 1)
≤ 1.7 A 2)
Outputs:
Safety outputs (OSSDs): 2 x 250 mA
Signal outputs: 3 x 100 mA 3)
1) At 24 V DC without output load.
2) At 24 V DC with maximum output load.
3) Freely programmable, e.g. warning field, contamination, reset required.
Item condition: new, from stock clearance (without original packaging)
Year of manufacture: 2022
You can find more scanners - new and used - in our shop!
International shipping costs on request!
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2008
541 listings online
Send inquiry
Telephone & Fax
+49 2862 ... show
These listings may also fit your interest.
Success:
Your message has been sent.
Listing
Borken
7,614 km
SICK S30B-3011BA Safety Laser Scanner Safety Scanner Laser Scanner S300
SickS30B-3011BA
SickS30B-3011BA
Your listing has been deleted successfully
An error has occurred