Used Climate Test Chamber With Solar Simulation for sale (15,060)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,614 km
Temperature shock chamber climate test
NemaNTS 3000 / 2S
Call
Year of construction: 2000, condition: good (used), Nema Temperature Shock Test Chamber -40°C to +120°C
Manufacturer: Nema
Type: NTS 3000 / 2S
Temp. Range: -40°C to +120°C
Line Voltage: 400 V
Rated Current: 88 A
Rated Power: 55 kW
Refrigerant: R 404 A
Year of Manufacture: 2000
Weight: 5000 kg
External Dimensions: W 4000 x D 2760 x H 3450 mm
Chamber: W 3000 x D 1250 x H 1610 mm
Fpsdpfxsuuiayj Ad Njg
TS-06
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,614 km
Corrosion climate change test chamber
WEISSSC 1000/+20IU
Call
Condition: excellent (used), Weiss SC 1000/+20IU Corrosion Climatic Cycle Test Chamber
Weiss SC 1000/+20 JU Corrosion Climatic Cycle Test Chamber
The test system is a combination of a climatic test chamber with variable temperature and humidity and a corrosion test chamber with a salt spray test.
At-risk metallic components are tested for corrosion in a time-lapse manner according to the relevant standards.
Temperature Working Range
Temperature: +20 °C ... +60 °C
Temperature variation over time: +0.5 °C
Climatic Working Range
Temperature: +20 °C ... +60 °C
Temperature variation over time: +0.5 °C
Relative Humidity: 10...98 % RH
Temperature variation over time: 3...5 % RH
Dew point: +12 °C ... +59 °C
Salt spray test SS (ambient temperature range +5 °C ... +50 °C)
according to DIN 50 021 (salt spray via dual-fluid nozzle, 1.5 x 0.5 mV 80 cm h)
Control
Digital measurement and control system SIMCON/32*-Net with touchscreen control panel
Interfaces - Serial interface RS 232 C - Parallel printer interface
Operating modes adjustable via process controller:
- Temperature mode
- Air conditioning mode
- Salt spray test
- Direct spraying with saline solution
- Condensate load
- Flushing test chamber walls
- Drying/ventilating test chamber
Temperature sensor: Pt 100 resistance thermometer
Humidity sensor: Psychrome fresh measuring device TFT (with forced humidification)
Technical data SC 1000/+20 JU
Usable space dimensions
Height up to
sloped roof approx. 1000 mm
+ roof approx. 350 mm
Width approx. 1100 mm
Width between heaters approx. 1000 mm
Depth approx. 1000 mm
Test room door made of glass, hinged on the left
Height approx. 1350 mm
Width approx. 1000 mm
External dimensions including unit components and control cabinet
Height approx. 2100 mm
Width approx. 1450 mm
Width with touch control panel approx. 1700 mm
Depth approx. 2600 mm
Floor load max. 100 kg
Fsdpfeph U Dhex Ad Njpg
Brine storage tank
approx. 200 l, with level monitoring separately next to/behind the unit
Height approx. 1000 mm
Width approx. 600 mm
Depth approx. 900 mm
Electrical connection: 400 V
Power rating: 13 kW
Weight: 1300 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items – new and used – in our shop!
International shipping costs on request!
Listing
Borken
7,614 km
Solar cells Photovoltaic Test chamber
Parker Hannifin GmbHVertical Light Stack Module
Call
Condition: like new (used), Year of construction: 2012, Parker Engineering & Design Vertical Light Stack Module
For testing solar modules Photovoltaic modules
Electrical and mechanical safety testing
Support for product development, design and quality control
Detection of potential problems during development
Quality and safety control
Endurance test stand
Temperature control
Fpsdpfx Adoh Rvh Sj Njg
Mobile on rollers
Entry pockets for forklift trucks
400 VAC, 3.PH, 50 AMP
IR. 10,000 amp
Year 2012
Weight 1400 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further test equipment - new and used - you will find in our shop!
International shipping costs on request!

Get information now
+49 201 857 86 122
+49 201 857 86 122
List now
*per listing / month
Listing
Borken
7,623 km
Climate test chamber +20 to +130°C, 240 l
Weiss TechnikEmissionEvent VOC/240
Call
Condition: excellent (used), Weiss
Type: EmissionEvent VOC/240
Weiss Technik EmissionEvent VOC/240
Industrial Emission Test Chamber / VOC Test Chamber / Climatic Test Cabinet
Water-cooled
A professional emission test chamber is offered for sale
Weiss Technik EmissionEvent VOC/240 (Year of manufacture: 2018)
from an industrial laboratory and testing operation.
The device is designed for conducting standardized emission tests under precisely controlled temperature,
climatic, and process conditions, and is built for continuous use in laboratories, industrial settings, and quality assurance.
What does VOC mean / What does the device do?
VOC = Volatile Organic Compounds
The device measures and tests the outgassing (emissions) of materials under defined conditions.
It analyses which substances are released into the air by a given material. Typical applications include:
- Emission testing of plastics, components, materials
- Automotive interior material testing (odor / pollutants)
- Building products & furniture emission measurement
- Packaging, textiles, adhesives, paints
- Quality control and standard testing (e.g. ISO / VDA / DIN)
The test system generates precisely defined temperature, humidity, and air conditions.
Emissions are extracted from the test space using a carrier gas (e.g. nitrogen or air)
and can subsequently be analyzed using appropriate measuring equipment.
Device features / Equipment:
- Stainless steel emission test chamber (hermetically sealed)
- Temperature and climate control
- Carrier gas system for emission measurement
- Automatic process control with touch panel
- Programmable operation / continuous operation possible
- Sampling ports for VOC analysis
- Industrial-grade construction (suitable for laboratory and continuous operation)
Technical data for temperature testing:
- Temperature range: +20 to +130 °C
- Temporal temperature deviation at chamber center: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.1 to ±0.5 K
- Temperature change rate (according to IEC 60068-3-5):
Heating: 0.4 K/min
Cooling: 0.3 K/min
- Temperature change rate (average, with enhanced heating and cooling capacity):
Heating up to +65 °C: 1.5 K/min
Cooling from +65 °C to +20 °C: 1.3 K/min
Technical data for climate testing:
- Temperature range: +20 to +130 °C
- Dew point range: +5 to +60 °C
- Relative humidity range: 5 to 95% RH
- Temporal temperature deviation: 0.1 to 0.3 K
- Temporal humidity deviation: -3 to 3% RH
Dimensions EmissionEvent VOC/240
External dimensions (unit):
Width: approx. 1350 mm, Depth: approx. 2500 mm, Height: approx. 1985 (2190) mm
Internal dimensions (test space):
Emission test chamber: 200 l
Gross test chamber volume: 240 l
Net test chamber volume: 208 l
Max. test sample load: 80 kg
Internal dimensions VOC/240:
Width: approx. 600 mm, Depth: approx. 560 mm, Height: approx. 600 mm
Fpedoyhfg Dspfx Ad Njg
Electrical:
Voltage: 3/N/PE AC 400 V ±10% / 50 Hz
Nominal power: 12.1 kW
Nominal current: 30 A
Protection class: IP54
Refrigerant:
R134a – 2.5 kg
Weight: approx. 1080 kg
Important information for you as the buyer:
The following procedures are carried out on the chambers we offer prior to sale:
1. Functional inspection and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Following successful inspection, a documented trial run is carried out
Condition: used
Scope of supply: (see picture)
(Technical data and specifications subject to change and errors!)
For further questions, feel free
Listing
Borken
7,623 km
Climate test chamber with humidity, 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Weiss
Model: WK3-340/40
Weiss Climate Test Chamber, Air-Cooled
Temperature Testing
Volume: 335 liters
Test Chamber Dimensions:
Internal Dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External Dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum Temperature: –42°C
Maximum Temperature: +180°C
Fpjdpfeygv U Njx Ad Njg
Temperature Change Rate, Cooling: 4 K/min
Temperature Change Rate, Heating: 3.2 K/min
Temperature Deviation Over Time: ± 0.1 to ± 0.5 K
Temperature Uniformity Spatially: ± 0.5 to ±1.5 K
Climate Testing:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% RH
Temperature Deviation Over Time: ± 0.1 to ± 0.3 K
Temperature Uniformity Spatially: ± 0.5 to ± 1 K
Humidity Deviation Over Time: ± 1 to ± 3 % RH
Halogen Lamp: 2 x 24V, 50W
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Power: 4.1 kW, Rated Current: 14 A
Refrigerant: R-404A
Weight: approx. 515 kg
For your security as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications reserved!)
Further questions can be answered by phone.
Listing
Borken
7,623 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Fodpoygvn Njfx Ad Nopg
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Listing
Borken
7,623 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
For further questions, we are happy to assist you by phone.
Fodpfx Aoygut Rjd Nspg
Listing
Borken
7,623 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Fodpfx Asygutwsd Nopg
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
7,623 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Fpsdpfoygur Tex Ad Neg
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
7,623 km
Climatic test chamber -5°C...+90°C
WeissWK111-600 600 Liter
Call
Condition: used, Weiss
Type: WK111-600
Weiss Climate Test Chamber, Air-cooled
Performance Data for Temperature Tests:
Temperature range: -5°C to +90°C
Temporal temperature fluctuation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1 K
(corresponds to temperature gradient): 1 to 2 K
Temperature change rate:
Heating: 0.5 K/min
Cooling: 0.2 K/min
Performance Data for Climatic Tests:
Temperature range: +10 to +90°C
Humidity range: 10 to 98% r.h.
Temporal temperature fluctuation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
(corresponds to temperature gradient): 1 to 2 K
Temporal humidity fluctuation: ±1 to ±3%
Test Chamber Dimensions: Width 800 mm x Depth 800 mm x Height 950 mm
Housing Dimensions: Width 1000 mm x Depth 1660 mm x Height 1975 mm
Access Ports:
1 access port Ø 50 mm on the left side installed
1 access port Ø 125 mm on the right side installed
Power Supply: 1/N/PE AC 230V ±10% 50Hz
Rated power: 2.3 kW
Rated current: 10.0 A
Refrigerant: R 404 A
Capacity: 600 liters
Weight: 540 kg
Fpedpfx Adoygum De Neg
For your security as a buyer, please note the following information!
The following steps are performed on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors excepted!)
If you have further questions, feel free to contact us by phone.
Listing
Borken
7,623 km
Climate test chamber with humidity
CTSCS-70/350 350 Liter -70°C /+180°C
Call
Condition: excellent (used), Here we offer you a climate chamber.
Water-cooled
Test chamber volume: 350 liters
Internal chamber dimensions: Height 750 mm, Width 650 mm, Depth 720 mm
External dimensions: Height 1800 mm, Width 850 mm, Depth 1640 mm
Temperature working range:
Temperature range: -70°C to +180°C
Cooling rate: 3.0 K/min
Heating rate: 5.0 K/min
Climate working range:
Temperature range: +10°C to +90°C
Humidity range: +10% to 98% RH
Dew point range: +5°C to 89.5°C
Temperature deviation: ±0.1 - ±0.3 K over time
Humidity deviation: ±1 - ±2% RH over time up to 90% RH
max. ±1 - 3% RH over time above 90% RH
Electrical connection: 400V +6-10%, 3/N, 50Hz
Connected load: 13 kW
Rated current: 25.5 A
Refrigerant: R404A / R23
Weight: 650 kg
Type: CS-70/350
For your safety as a buyer, please note the following information:
Fpodpfx Adsygumko Njg
The following steps are performed in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a trial run which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (see photo)
(Specifications, technical data and details may be subject to change. Errors excepted.)
For any further questions, we are happy to assist you by phone.
Listing
Borken
7,623 km
Climate test chamber 600 liters with humidity
WeissWK3-600/0-M -5°C bis +90°C
Call
Condition: excellent (used), Weiss
Model: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Series: WK3-../0
with SIMPAC* Controller
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Operating data:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Site-provided fuse: 16 A slow-blow
Control cabinet and operator panel protection class: IP 54
Maximum heat emission to environment: 1200 W
Sound pressure level:
Fodpfxsygulms Ad Nepg
Measured at a distance of 1m from the front, at a height of 1.6m: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient (according to IEC 60068-3-5)
Temperature change rate:
Heating 0.6 K/min
Cooling 0.3 K/min
Heat compensation at +20°C to +50°C: 200 W
Data for climatic tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5°C
Humidity range: 10 to 98 % r.h.
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temporal humidity deviation: +1 to +3 % r.h.
Refrigerant: R-404A
Weight: 610 kg
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functionality check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Technical data and information subject to change and errors!)
We are happy to answer any further questions you may have by phone.
Listing
Eindhoven
7,564 km
Climate test chamber
Vötsch/WeissGTTS 220
Call
Condition: used, Year of construction: 1980, functionality: unexamined, machine/vehicle number: GTTS 220, total height: 144 mm, total length: 135 mm, total width: 96 mm, Equipment: documentation/manual, Used Votsch/Weiss GTTS 220 Climate Chamber
Manufacturer: Votsch/Weiss
Model: GTTS 220 | 20
External dimensions: 135cm x 96cm x 144cm (length x width x height)
Max internal dimensions: 65cm x 92cm x 54/40cm (width x depth x height)
Fpjdpfex H N Drjx Ad Nsg
Voltage: 220/380 V
Refrigerant type: R12
Includes manual (installation and operation handbook)
Listing
Borken
7,623 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Fsdpfxjuudx Do Ad Nepg
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Fpodpfxjv N Hc Es Ad Neg
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), Here we offer a climatic test chamber.
Air cooled
Fpedpjiz Tqcsfx Ad Nog
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
+5 to +100 C
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80 water cooled
Cold-heat operation: -75°C ...+180°C
Climatic operation: +10...+95°C
Humidity range: 10...98 % r. h.
Temperature constancy, temporally ± 0.2K
Humidity constancy: ±1 r.F.
Temperature rate of change:
Cooling: approx. 1.4 K/min
Fsdpfxsm Tvzco Ad Nepg
Heating up: approx. 2.5 K/min
External dimensions: Height 1980 mm, width 1265 mm, depth 1365 mm
Feedthroughs:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/ 50 Hz
Power: 10,4 kVA
Weight: approx. 720 kg
Refrigerant R404a / R 23
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
Climate test chamber 900 liters
CTSCS-70/900 -70...+180°C
Call
Condition: used, Type: CS-70/900
CTS Climate Test Chamber with Humidity, water-cooled
(converted to R-452a refrigerant)
Temperature range: -70°C to +180°C
Humidity range: 10–98% RH
Test chamber internal dimensions: Height approx. 870 mm / Width approx. 1000 mm / Depth approx. 1000 mm
External dimensions: Height approx. 1950 mm / Width approx. 1200 mm / Depth approx. 2220 mm
Control cabinet dimensions: Height approx. 2100 mm / Width approx. 800 mm / Depth approx. 400 mm
Test chamber volume: 900 liters
Refrigerant: R-452a / R23
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Connected load: 21.2 kW, Rated current: 35.7 A
Chamber weight: 900 kg
Control cabinet weight: 150 kg
Fjdpfjxb Dm Iex Ad Nepg
Important safety information for buyers:
The following steps are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
For any further questions, please contact us by phone.
Listing
Borken
7,623 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Fpjdpfow I Rxrex Ad Neg
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Weight: approx. 2,100 kg
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Climate test chamber Temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate chamber water-cooled
(test room explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST ROOM
Technical data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Fodpfxov Ewy Ho Ad Njpg
Test room capacity: approx. 600 liters
Cold / heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98% r. H.
Temperature change per time
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
On-site fuse: 32 A slow-blow
Permissible test item weight
Total load of the grate supports 80 kg
Test room floor 80 kg, grate insert 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The air conditioning system's evaporator has been replaced)
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation in time K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Fodpfouxq T Dex Ad Njpg
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Used-Machines

Listing
Borken
7,623 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Fjdpfx Aok E Hnqjd Nepg
Type: 3702/06
Water-cooled climatic test chamber
Technical data:
Test chamber nominal volume 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width 2970 mm Height 2370 mm Depth 1530 mm
Rear wall
Minimum insertion dimensions: Width 2970 mm Height 2390 mm Depth 1550 mm
Test chamber: Width 2000 mm Height 1000 mm Depth 1000 mm
Double-leaf door, clear width Width 2000 mm Height 1000 mm
Heated viewing window, 2 pieces Width 500 mm Height 600 mm
Feed-through opening, 1 side panel left ∅ 75 mm
Temperature range: -40...100°C
Climatic range: 10...95°C
Temperature difference, temporal ≤ ± 0.5...± 1.0 ΔN/K
Change rates measured in the supply air without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 %r. F.
Humidity difference, temporal ≤ ± 3.0 %r. F.
Dew point range, temporary down to -5... 95°C
Refrigeration system: water-cooled semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Air conditioning and dryer refrigeration system air-cooled /hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical mains connection: 400V 3/N/PE.AC,50Hz
Mains plug: CEE 5-роlig, 32 A, with 5.0 m cable
Max. simultaneous power requirement 10.0 kW
Supply line fuse: 3x 25, Char, C A
Degree of protection IP20
Weight: 1300 kg
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climatic test chamber 800 L, -55°C to +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
Call
Year of construction: 2020, condition: excellent (used), Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Fpjdew R Rt Ispfx Ad Neg
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
Listing
Borken
7,623 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
Fsdpfx Adjwgayks Nopg
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Battery test system with climate chamber
Keysight / Scienlab / AngelantoniBatterie-Testsystem SL1001A
Call
Condition: used, Keysight / Scienlab Battery Test System SL1001A + Angelantoni Climate Chamber DM500 C 10 ESS SPEEDY BT SP
Complete Battery Testing System – For Laboratory Use
Incl. PC, software & technical documentation
For sale is a professional battery test system, consisting of:
- Keysight / Scienlab SL1001A Battery Test System
- Angelantoni DM500 C 10 ESS SPEEDY BT SP Climate Chamber
- Monitoring/Sampling Unit
- Control PC with original software
- Technical documentation
The system is fully functional, well-maintained, and ideally suited for battery module testing, research, development, and quality assurance.
Technical Data – Scienlab SL1001A:
- Manufacturer: Keysight / Scienlab
- Model: SL1001A
- Year of manufacture: 2020
Fjdpfexuqk Hox Ad Nopg
- Voltage / Current / Power: 80 V / 600 A / 24 kW
- Dimensions (L×W×H): approx. 1.6 × 0.9 × 3.3 m
- Weight: approx. 700 kg
- Function: Charging, discharging, and cycling of battery modules
- Condition: Very well maintained, laboratory use only
Technical Data – Angelantoni DM500 C 10 ESS SPEEDY BT SP:
- Manufacturer: Angelantoni Industrie S.r.l., Italy
- Model: DM500 C 10 ESS SPEEDY BT SP
- Year of manufacture: 2019
- Weight: approx. 1,225 kg
- Temperature range: -70 °C ... +180 °C
- Humidity range: 10 ... 98 % rH
- Refrigerants: R449A + R23
- Pressure ranges (PS Hi/Lo): 28 bar / 8 bar
- Wi-Fi integrated
- CE certification present
- Internal dimensions (L×W×H): approx. 1.6 × 2.3 × 3.3 m
- Function: Temperature and humidity testing, ESS (Environmental Stress Screening)
- Power supply: 3PH + N + PE, 400 V ±10 %, 50 Hz, full load 54 A
- Max. power consumption: 32.5 kW
Monitoring / Sampling Unit:
- Dimensions: 0.6 × 0.5 × 0.2 m
- Measured variables: Cell voltages, current, temperature
- Interfaces: CAN, Ethernet
- Compatible with Scienlab / Keysight PathWave software
PC + Software + Documentation:
- Industrial PC with control and measurement software
- Enables automated test runs, logging, and data analysis
Overall Dimensions / Weight (approx.):
Component Dimensions (L×W×H) Weight
Scienlab SL1001A 1.6 × 0.9 × 3.3 m 700 kg
Angelantoni Chamber 1.6 × 2.3 × 3.3 m 1,225 kg
Monitoring / PC 0.6 × 0.5 × 0.2 m 50 kg
Total system L 3.2 m × W 2.5 m × H 3.3 m approx. 1,975 kg
Applications:
- Development, testing, and lifespan analysis of battery modules (e.g., Li-ion, LFP, NMC)
- Fast charging and cycle tests
- Environmental simulation for temperature and humidity
- Research, industrial, and university laboratories
Important Note:
"The table shown in the photos is not included in the sale."
Scope of Delivery:
- Scienlab SL1001A power unit
- Angelantoni DM500 C 10 ESS SPEEDY BT SP climate chamber
- Monitoring/Sampling unit
- Control PC with software
- Technical documentation and manuals
- Connection cables and accessories (as available)
Condition: used
Scope of delivery: (see image)
(Specifications and data are subject to change and error!)
For any further questions, we are happy to assist you by phone.
We make it easier for you to find: "climate test chamber with solar simulation"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time

Get information now
+49 201 857 86 122
+49 201 857 86 122
List now
*per listing / month




































































































































































































































































