Used Espec Pl-3Kph -40°C Bis 180°C for sale (72,767)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Temperature shock chamber 200 liters
EspecTSA-202E-W -55°C bis 200°C
Call
Condition: excellent (used), Espec
Type: TSA-202E-W
Temperature Shock Chamber, Water-Cooled
Cold Chamber: -55°C to 0°C
Hot Chamber: +50°C to 200°C
System: Two-zone test with damper control
Temperature fluctuation ±0.5°C
Hot Chamber:
Temperature heating time: Ambient temperature (20°C) to +200°C within 15 minutes.
Cold Chamber:
Temperature reduction time: Ambient temperature (20°C) (20°C) to -55°C within 35 minutes.
Temperature recovery: within 5 minutes.
Internal dimensions (W x H x D mm): 650 x 460 x 670
External dimensions (W x H x D mm): 1550 x 1900 x 1670
Approx. 200 liters
Power supply: 400 V AC 50Hz: 65 A
Refrigerant: R404A 5 kg R23 2.0 kg
Weight: Approx. 1200 kg
For your safety as a buyer, please note the following:
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
Bodowc R A Ijpfx Adisdc
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature shock test chamber
EspecTSD-100 -70 °C bis +200 °C
Call
Condition: excellent (used), Here we offer a temperature shock test chamber.
with 100 liters of usable space for larger test specimens up to 30 kg.
Compliant with all current international standards.
Bdsdpen Smtmefx Adioc
Water cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrost
Overtemperature protection
Operating hours counter
Mobile version
2 test material baskets made of stainless steel
Cable gland Ø 100 mm
Refrigerant: 3 kg R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Type: TSD-100
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
7,623 km
With moisture 1000 liters
CTS KlimaprüfschrankC-70/1000-S -70°C bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber C-70/1000-S
Device Data
Manufacturer: CTS GmbH
Model: C-70/1000-S
Year of manufacture: 08/2011
Serial number: 113054
Type: Climate test chamber / Environmental simulation chamber
Cooling: Water-cooled
Description
Used CTS climate test chamber for precise temperature and climate testing.
Suitable for material, component, and reliability testing.
Applications in industry, research, development, and quality assurance.
Temperature and Climate Data
Temperature range: -70 °C to +180 °C
Temperature change rate: approx. 2.5 K/min heating
Temperature change rate: approx. 2.5 K/min cooling
Humidity range: 10% to 98% RH
Dew point range I: +7 °C to +94 °C
Dew point range II: -10 °C to +7 °C
Electrical Data
400 V / 3/N / 50 Hz
Power: 9.7 kW
Current: 17.9 A
Protection class: IP 22
Cooling System
Refrigerants: R404A / R23
Pre-cooling stage: R404A, 2.3 kg
Cooling stage: R23, 0.86 kg / 15 bar
Operating overpressure PS: 25 bar
Test pressure PT: 27.5 bar
Features
CTS control unit with LCD display
Programmable operation
Digital setpoint/actual value display
Viewing window in door
Stainless steel test chamber
Test specimen protection / temperature limiter
Interior lighting
Cable ports on the sides
Feedthroughs approx. 50 mm and approx. 125 mm
RS232 interface as per documentation
Digital outputs for test specimen control
Mobile design on castors
Dimensions
Test chamber volume: approx. 1000 liters
External (W x D x H): approx. 2245 x 1270 x 1950 mm
Installation size (W x D x H): approx. 2350 x 1290 x 2000 mm
Weight
Test chamber: approx. 1000 kg
Recooler: approx. 120 kg
Documentation
Declaration of conformity
Test certificates
Operating manual
Error messages and digital channels
Site plan
Quick guide
Humidity diagram
Scope of Delivery
CTS Climate Test Chamber C-70/1000-S
Documentation as available
Scope of delivery as shown
Optional Pre-delivery Service
Function test
Refrigerant service
Leak test
Test run with protocol
Bdedpjy Iam Hofx Adiec
Condition
Used.
Condition as per photos.
Note
Used equipment, sold without warranty.
Inspection possible by appointment.
Loading and transport can be organized on request.
Subject to prior sale and technical changes.
If you have any questions, please feel free to contact us.
Listing
Borken
7,623 km
Temperature shock chamber 580 liters
RS-SimulatorenST2K 1000/55 -70°C bis +180°C
Call
Condition: excellent (used), RS-Simulatoren Temperature Shock Chamber ST2K 1000 / 55
The system was regularly serviced and maintained by the manufacturer until it was decommissioned.
Equipment Data
Bdsdpoy H Igfofx Adijc
Manufacturer: RS-Simulatoren
Model: ST2K 1000 / 55
Design: Temperature shock chamber
Cooling: Water-cooled
Description
Used temperature shock chamber for standard-compliant thermal shock testing. Suitable for material, component, and reliability testing. Used in industry, automotive, research, and quality assurance.
System Description
• 2 separate temperature chambers (hot/cold)
• Automatic horizontal transfer of test basket
• Rapid switch operation for temperature shock testing
Temperature Ranges
Hot chamber: +40 °C to +180 °C
Cold chamber: -70 °C to +100 °C
Time deviation: ±0.8 K
Test Chamber
Volume: approx. 580 liters
Internal dimensions (W x H x D): approx. 1070 x 680 x 800 mm
Max. load: approx. 150 kg
Power Supply
400 V / 3~ / N / PE / 50 Hz
Power: max. 33 kVA
Current draw: max. 65 A
Media Connections
Cooling water: G 1", approx. 3 bar (max. 10 bar)
Cooling water consumption: max. 3.2 m³/h
Cooling water return: zero pressure
Compressed air: NW 7.2, 4–10.5 bar
Dimensions
External (W x H x D): approx. 2800 x 2400 x 2200 mm
Weight
approx. 2800 kg
Equipment Features
• Horizontal basket movement
• C-rails in test chamber
• Large test basket (>1000 mm)
• Observation window
• Interior lighting
• SE-604 controller
• Program operation and data logging
• RS232 interface
Refrigeration System
Refrigerants: R449A / R23
R449A: approx. 8.0 kg
R23: approx. 2.5 kg
Operating Data
Operating hours: approx. 4,500 hrs
Sound level: approx. 67 dB(A)
Ambient Conditions
Temperature: +12 °C to +30 °C
Humidity: 25 % to 75 % rH
Scope of Delivery
RS-Simulatoren Temperature Shock Chamber ST2K 1000 / 55
Scope of delivery as shown
Optional service before delivery:
• Function test
• Refrigerant service
• Leak test
• Trial run with protocol
Condition
Used.
Condition as shown in the pictures.
Note
Used equipment, sold without warranty.
Inspection possible by appointment.
Loading and transport can be organized upon request.
Subject to change and prior sale.
If you have any questions, please feel free to contact us.
Listing
Borken
7,623 km
Climatic test chamber with humidity, 600 liters
RS-SimulatorenKSS600/75-10K -75°C bis +180°C
Call
Condition: excellent (used), RS-Simulatoren Climate Chamber KSS 600/75-10K
Device Data
Manufacturer: RS-Simulatoren Prüf- und Messtechnik GmbH
Model: KSS 600/75-10K
Design: Climate Test Chamber / Environmental Simulation Chamber
Cooling: Water-cooled
Description
Used climate test chamber from RS-Simulatoren. Suitable for temperature tests, climate tests, material, and aging tests. For use in industrial testing and measurement applications.
Technical Data
Temperature range: -75 °C to +180 °C
Temperature change rate: heating/cooling approx. 10 K/min
Test chamber volume: approx. 600 liters
Dimensions
Internal (W x D x H): 840 x 840 x 840 mm
External (W x D x H): 1200 x 1600 x 1995 mm
Electrical Data
400 V / 3~ / N / PE
Current consumption: approx. 55 A
Refrigeration System
Refrigerants: R404A / R23
R404A: 6.0 kg
R23: 3.0 kg
Weight
approx. 1,400 kg
Equipment
Bjdpfxey H Ib Ae Adiedc
- RS-Simulatoren control / operating panel
- Programmable operation
- Observation window
- Temperature monitoring in the test chamber
- Operating hours counter
- Side feedthrough
- Robust industrial design
Scope of Delivery
- RS-Simulatoren climate chamber KSS 600/75-10K
- Delivery as shown
Service before delivery (optional)
- Functional test
- Refrigerant service
- Leak test
- Test run with protocol
Condition
Used.
Condition as per images.
Note
Used device, sold without warranty.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to prior sale and changes.
If you have any questions, please feel free to contact us.
Listing
Borken
7,623 km
Climate test chamber with humidity control
BinderMKFT 720 E3.2 -70°C bis 180°C
Call
Condition: excellent (used), Binder Climate Test Chamber MKFT 720 E3.2
Device Information
Manufacturer: Binder
Model: MKFT 720 E3.2
Year of Manufacture: 2017
Item Number: 9020-0288
Design: Climate Test Chamber (Change-over type)
Cooling: Air-cooled
Description
Used Binder climate test chamber.
Suitable for temperature, climate, material, and aging tests, as well as stress tests.
Intended for applications in industry, research, development, and quality assurance.
Technical Specifications
Temperature Range: -70 °C to +180 °C
Humidity Range: 10% to 98% RH
Internal Volume: approx. 734 liters
Max. Total Load: 160 kg
Max. Load per Shelf: 40 kg
Dimensions
Bdedpfx Asy H H Smedioc
External (W x H x D): 1615 x 2005 x 1230 mm
Internal (W x H x D): 1200 x 1020 x 600 mm
Electrical Data
400 V / 3N~ / 50 Hz
Power: 13.0 kW
Current: 22.5 A
Protection Class: IP 20
Refrigeration System
Refrigerant: R404A / R23
Stage 1: 4.00 kg
Stage 2: 0.87 kg
Two-stage refrigeration system
Max. Operating Pressure: 29 bar
Performance Data - Temperature
Temporal temperature deviation: 0.1 to 0.5 K
Spatial temperature deviation: 0.3 to 2.0 K
Heating rate: approx. 4.8 K/min
Cooling rate: approx. 4.0 K/min
Heat compensation: approx. 5000 W
Performance Data - Climate
Climatic range: +10 °C to +95 °C
Humidity range: 10% to 98% RH
Temperature deviation: 0.1 to 1.0 K
Heat compensation: approx. 800 W
Features
Touch control panel
Programmable and constant operation modes
Observation window
Stainless steel test chamber
Interior lighting
Cable port
Mobile on castors
Robust industrial design
Weight
Approx. 635 kg
Scope of Delivery
Binder climate test chamber MKFT 720 E3.2
Scope of delivery as shown
Service prior to delivery (optional)
Functional test
Refrigeration service
Leak test
Test run with protocol
Condition
Used. Condition as per images.
Note
Used equipment, sold without warranty.
Inspection by appointment possible.
Loading and transport can be arranged on request.
Subject to prior sale and changes.
If you have any questions, feel free to contact us.
Listing
Borken
7,623 km
With moisture 600 liters
CTS KlimaprüfschrankC-70/600 -70°C bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber C-70/600
Device Data
Manufacturer: CTS GmbH
Model: C-70/600
Type: Climate Test Chamber
Cooling: Water-cooled
Description
Used climate test chamber from CTS. Suitable for temperature and climate testing. Designed for use in research, development, and quality assurance.
Operating Status
Display: Manual operation / Stop.
Temperature: 16.59 °C (actual) / 5.00 °C (set).
Humidity: 39.7 % RH.
Water reserve: 11.0 liters.
Technical Specifications
Temperature range: -70 °C to +180 °C
Humidity range: 10 % to 98 % RH
Dew point range: -10 °C to +94 °C
Test chamber volume: 600 liters
Electrical Data
400 V / 3/N / 50 Hz
Power: 8.7 kW
Current: 14.8 A
Protection class: IP 22
Refrigeration System
Refrigerant: R404A / R23
Cascade refrigeration unit
Low temperature operation down to -70 °C
PS: 25 bar
PT: 27.5 bar
Features
Viewing window
Stainless steel test chamber
Bodpfsy H H D Aox Adisdc
Digital set/actual value display
Sample protection / temperature limiter
Water connection (deionized water)
Condensate drain
Cable ports
RS232 interface
Digital outputs
Dimensions
Internal: approx. 850 x 850 x 830 mm
External: approx. 1900 x 1115 x 1850 mm
Weight
approx. 600 kg
Scope of Delivery
CTS Climate Test Chamber C-70/600
Documentation (if available)
Pre-delivery service (optional)
Functional testing
Refrigerant service
Leak testing
Trial run with protocol
Condition
Used. Condition as shown in the images.
Note
Used equipment, sale without warranty.
Inspection possible by appointment.
Loading and transport can be arranged on request.
Subject to prior sale and modifications.
If you have any questions, please do not hesitate to contact us.
Listing
Borken
7,623 km
With moisture 600 liters
CTS KlimaprüfschrankCS-70/600-5/S 70°C bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber CS-70/600-5/S
Device Data
Manufacturer: CTS GmbH
Model: CS-70/600-5/S
Design: Climate Test Chamber
Cooling: Water-cooled
Description
Used climate test chamber from CTS. Suitable for temperature, climate, and stress screening tests. For use in industry, research, and quality assurance.
Operating Condition
Bdodpfjy H Hmwjx Adijc
Display: Manual mode / Warning (Drain water bath).
Operating Hours
Total: 19,788 h
Compressor cooling: 8,699 h
Compressor pre-cooling: 11,432 h
Pump circulation: 2,905 h
Technical Data
Temperature range: -70 °C to +180 °C
Humidity range: 10% to 98% RH
Dew point range: -10 °C to +94 °C
Test chamber volume: 600 liters
Electrical Data
400 V / 3/N / 50 Hz
Power: 18.4 kW
Current: 30.6 A
Protection class: IP 22
Refrigeration System
Refrigerants: R404A / R23
Pre-cooling stage: 5.0 kg
Cooling stage: 2.1 kg / 14.5 bar
CO₂ equivalent: 19.61 t / 30.93 t
GWP: 3922 / 14800
Pressure Data
PS: 25 bar
PT: 27.5 bar
Features
Observation window
Stainless steel test chamber
CTS touch/LCD control panel
Programmable operation
Specimen protection / temperature limiter
Water-cooled refrigeration unit
Humidity system with water bath
Automatic water refilling possible
Interfaces (RS232 / Ethernet)
Integrated control cabinet
Industrial version
Feedthroughs
1x NW 50
2x NW 125
Dimensions
Interior: approx. 850 x 850 x 830 mm
Exterior: approx. 1900 x 1120 x 1875 mm
Weight
Approx. 750 kg
Scope of Delivery
CTS Climate Test Chamber CS-70/600-5/S
Documentation / Test certificates (if available)
Pre-shipment Service (optional)
Functional test
Refrigerant service
Leak test
Test run with protocol
Condition
Used. Visual condition see pictures.
Note
Used equipment, sale without warranty. Inspection by arrangement possible. Loading and transport can be organized upon request.
Subject to changes and prior sale.
If you have any questions, please do not hesitate to contact us.
Listing
Borken
7,623 km
With moisture 600 liters
CTS KlimaprüfschrankC-70/600 -70°C bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber C-70/600
Device Data
Manufacturer: CTS GmbH
Model: C-70/600
Design: Climate Test Chamber
Cooling: Water-cooled
Description
Used climate test chamber from CTS. Suitable for temperature and climate testing. Intended applications include industry, research, and quality assurance.
Technical Specifications
Temperature range: -70 °C to +180 °C
Humidity range: 10% to 98% RH
Dew point range: -10 °C to +94 °C
Test chamber volume: 600 liters
Electrical Data
400 V / 3/N / 50 Hz
Power: 8.7 kW
Current: 14.8 A
Protection class: IP 22
Cooling System
Refrigerants: R404A / R23
Bdjdpfxsy H Hl Ho Adiec
Cascade refrigeration system
Low-temperature operation down to -70 °C
PS: 25 bar
PT: 27.5 bar
Features
Observation window
Stainless steel test chamber
Digital setpoint/actual value display
Test specimen protection / Temperature limiter
Water connection (deionized water)
Condensate drain
Cable ports
RS232 interface
Digital outputs
Dimensions
Internal: approx. 850 x 850 x 830 mm
External: approx. 1900 x 1115 x 1850 mm
Weight
Approx. 600 kg
Scope of Delivery
CTS Climate Test Chamber C-70/600
Documentation (as available)
Service prior to delivery (optional):
- Functional check
- Refrigerant service
- Leak test
- Test run with protocol
Condition
Used.
Visual condition as shown in the images.
Note
Used equipment, sold without warranty.
Inspection by appointment possible.
Loading and transportation can be organized upon request.
Subject to prior sale and changes.
If you have any questions, feel free to contact us.
Listing
Borken
7,623 km
With moisture 600 liters
CTS KlimaprüfschrankC-70/600 -70°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-70/600
CTS C-70/600 climate testing chamber
air-cooled version
with observation window, test item protection, and documentation
For sale is a high-quality CTS climate testing chamber, type C-70/600,
for precise temperature and climate testing in research,
development, quality assurance, and industry.
Technical data:
Temperature range: -70 °C to +180 °C
Humidity range: 10 % to 98 % RH
Dew point range: -10 °C to +94 °C
Test chamber volume: 600 liters
Electrical connection: 400 V 3/N 50 Hz
Rated power: 8.7 kW
Rated current: 14.8 A
Protection class: IP 22
Refrigerant: R404A (pre-cooling stage) / R23 (cooling stage)
Cascade refrigeration system for low-temperature operation down to -70 °C
Operating overpressure PS: 25 bar
Test pressure PT: 27.5 bar
Equipment / features:
Observation window in the door
Stainless steel test chamber
CTS control panel with digital setpoint/actual value display
Bdodpfxoy Hkazs Adisc
Test item protection / temperature limiter
Water connection / demineralized water inlet
Test chamber and condensate drain
Pipe penetrations on the side of the test chamber
RS232 interface as per documentation
Digital outputs for test item control
Test chamber dimensions as per documentation:
approx. 850 x 850 x 830 mm
External dimensions as per documentation:
approx. 1900 x 1115 x 1850 mm
Weight as per documentation: approx. 600 kg
Scope of delivery:
CTS climate testing chamber C-70/600
including existing documentation / operating manuals
Scope of delivery as shown in the pictures
For your safety as a buyer:
The unit can be inspected by arrangement.
Loading with a forklift can be organized.
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber 1000 liters
WeissWT-1000/70/5 -70 °C bis +180 °C
Call
Condition: excellent (used), Weiss WT-1000/70/5 Temperature Test Chamber
For sale is a pre-owned temperature test chamber manufactured by Weiss, model WT-1000/70/5.
This unit is designed for precise temperature testing in industrial and laboratory environments, and is suitable for use in research, development, and quality assurance applications.
The test chamber allows for reproducible temperature cycles across an extended temperature range and is particularly suitable for material testing, aging tests, and stress tests under defined temperature conditions.
Technical Data
Manufacturer: Weiss
Model: WT-1000/70/5
Type: Temperature Test Chamber
Temperature Range: -70 °C to +180 °C
Temperature Deviation (over time, center of usable space): ± 0.1 to ± 0.5 K
Temperature Homogeneity (spatial): ± 0.5 to ± 2 K
Heating rate: 6.1 K/min
Cooling rate: 6 K/min
Test chamber volume: approx. 1000 liters
Test chamber dimensions (approx.): 950 x 1100 x 950 mm (H x W x D)
External dimensions (approx.): 2000 x 1415 x 2105 mm (H x W x D)
Permissible total load, test chamber floor: 150 kg
Permissible load per shelf: 50 kg
Rated voltage: 3/N/PE AC 400 V ± 10% / 50 Hz
Rated current: 38 A
Rated power: 26 kW
Refrigerants: R404 / R23
Bsdpfxsy D Nyus Adijdc
Weight: approx. 955 kg
Features
- Water-cooled system
- Spacious test chamber
- High rate of temperature change
- Industrial grade construction
Condition
Used, with age- and use-related signs of wear.
Service / Inspection
For quality assurance, the following work is carried out on the offered systems:
- Function check and replacement of necessary components
- If required, refilling with legally compliant refrigerant
- Leak test with certificate
- Documented test run following successful inspection
Scope of delivery
- Weiss WT-1000/70/5 temperature test chamber
- Accessories as shown
Notes
- Connection via 400 V three-phase power required
- Shipping by freight carrier required due to size and weight
- Sale from commercial inventory
- All information subject to change
- Prior sale reserved
- For further information, feel free to contact us.
Listing
Borken
7,623 km
Climate test chamber 350 liters with humidity control
CTSC -40/350 -40°C /+180°C
Call
Condition: excellent (used), CTS
Type: C-40/350
Bedpex Ekupofx Adiodc
Air-cooled Climate Test Chamber
For sale is a professional CTS climate test chamber, model C-40/350. This device is designed for demanding environmental simulations in industrial applications and is ideal for material testing, electronics, automotive, aerospace, and research.
Temperature Testing:
- Temperature range: -40°C to +180°C
- Temperature deviation: ≤ ±0.3 K over time
- Temperature change rate according to IEC 60068-3-5:
- Heating: 3.5 K/min
- Cooling: 4 K/min
- Heat compensation:
- Approx. 3500 W at +20°C
- Approx. 2000 W at -20°C
Climatic Testing:
- Temperature range: +10°C to +90°C
- Humidity range: 10% to 95% relative humidity
- Dew point range: +5°C to +78°C
- Temperature deviation: ≤ 1.0 K over time
- Humidity deviation: ≤ ±3.0% r.h. over time
Technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without heat compensation, and without additional accessories. Options may influence performance data.
Technical Specification:
- Refrigeration unit: Air-cooled, low-noise, fully hermetic, infinitely variable performance adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
- Test chamber floor load: 150 kg/m²
- Shelf: Stainless steel, support surface 620 x 600 mm
- Maximum load per shelf: 35 kg
- Total load with maximum number of shelves: 100 kg
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numeric entry of setpoints
- Plain-text error messages
- RS 232 interface
- Ethernet interface
- Free switching channels for external test sample control
Dimensions:
- Test volume: 350 liters
- Internal dimensions: Height 750 mm × Width 650 mm × Depth 720 mm
- External dimensions: Height 1800 mm × Width 920 mm × Depth 1670 mm
Operating Data:
- Electrical connection: 400V 3/N, 50 Hz
- Rated power: 7.1 kW
- Rated current: 11.5 A
- Protection class: IP 54
- Sound pressure level:
Listing
Borken
7,623 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Bdsdpfjhh H Hisx Adijc
Heraeus Vötsch temperature test chamber water cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ±0,1 to ±0,5 K
Temperature deviation in time ±0.5 to ±2.0 K
Temperature change rate cooling 7.5 K/min
Temperature change rate heating 7.5 K/min
Heat compensation +20°C 3000 W
Heat compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 450 mm Height 750 mm
Outer dimensions: Width 870 mm Depth 1280 mm Height 1575 mm
Observation window:
Width 300 mm x height 540 mm
Test chamber volume 190 litres
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50Hz
Rated power: 10.5 kW Rated current: 22 A
Fuse, on-site: 32 A slow-blow
Sound level at 1m distance (free field measurement) < 69dB (A)
lateral feed-through 50 cm / 125 cm
Cabinet is water cooled
Refrigerant: R 404A and R 23
Weight approx. 460 kg
Type: VTS 7018-5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. function check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing
Borken
7,623 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch Type: VTS 7018-5 Heraeus Vötsch Temperature Test Chamber, Water-Cooled Temperature range: -70°C to +180°C Temporal temperature deviation: ± 0.1 to ± 0.5 K Spatial temperature deviation: ± 0.5 to ± 2.0 K Temperature change rate (cooling): 6.5 K/min Temperature change rate (heating): 7.5 K/min Heat compensation: 4,500 W Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm External dimensions: Width 870 mm x Depth 1,280 mm x Height 1,575 mm Viewing window: Width 300 mm x Height 540 mm Test chamber volume: 190 liters Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz Rated power: 10 kW Rated current: 21 A Supply-side fuse: 32 A slow-blow Sound level at 1 m distance (free-field measurement): < 63 dB(A) Lateral port: 50 cm / 125 cm Chamber is water-cooled Refrigerants: R452A and R23 Weight: approx. 460 kg Important safety information for buyers: The following procedures are carried out on all chambers offered by us: 1. Functional check and replacement of necessary components 2. If required, refilling with legally compliant refrigerant 3. Leak test with certificate 4. After successful inspection, all chambers are subjected to a documented trial run. Condition: used Scope of delivery: (see photos) (Technical data and specifications subject to change and errors!) If you have further questions, we are happy to provide information by phone.
Bdodeyu Rhgopfx Adiec
Listing
Borken
7,623 km
Walk-in climate simulation cell
TIRAKB 127 TCZ 4022 S -2K -40 bis +140°C
Call
Condition: excellent (used), TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation chamber
System Structure:
The unit consists of the following main assemblies:
- Walk-in, insulated chamber
- Air handling room
- Humidification system
- Machinery room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
- Cooling rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% RH (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% RH, measured in supply air
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% RH (without thermal test chamber load; with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (WxDxH): approx. 2260 x 4648 x 2260 mm
- External dimensions (WxDxH): approx. 2660 x 6460 x 2800 mm
- Clear door passage test chamber door (WxH): 2260 x 2260 mm
- Climate module KB 127 (WxDxH): 1700 x 800 x 1400 mm
- Control cabinet (WxDxH): 800 x 500 x 2000 mm
Design:
- Airflow: Supply air via perforated plate at the rear wall, ceiling area; exhaust air via perforated plate at the rear wall, floor area
- Temperature control: Direct cooling via evaporation of refrigerant in a finned heat exchanger; heating via electric resistance heater
- Dehumidification: Direct dehumidification via refrigerant evaporation in a heat exchanger
- Interior lining: Stainless steel
- Exterior cladding: Galvanized, plastic-coated steel sheet
- Floor: Stainless steel, floor load 15,000 N/m²
- Wheel load (contact area ≥4 cm²): 1,500 N/wheel
- Door: Double-leaf, stainless steel, externally coated with viewing window (WxH): 1000 x 1000 mm
- Test area lighting: 4 spotlights, 500 W each
- Insulation: Dual-layer insulation, 80 mm PUR foam, 120 mm mineral wool
Bdsdpfxevx S Hhj Adiec
- Refrigeration unit (1 pc): Bitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc): EDB 40
Color scheme:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidification unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10%, 3/PE N, 50Hz
- Rated power: 95 kW
- Rated current: 150 A
Listing
Borken
7,623 km
Climate test cell with humidity
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test chamber.
Feutron Climate Test Chamber
Temperature
Temperature range: -40...90°C
Climatic range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climatic operation: ± 1.0... ± 1.5 K/min
Change rates
Heating: avg. 2.0 K/min
Cooling: avg. 2.0 K/min
Standard IEC 1646 is achievable with testing, solar modules up to max. 160kg weight and nonlinear ramps (setpoint jump)
Drying
Air drying: condensation drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95 % r.h.
Temporal humidity deviation: ≤ ± 3.0... ±5.0 % r.h.
Dew point range: 8...80.9°C
Test Chamber
Test chamber volume: 7.0 m³
Dimensions
Internal dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Swing door DIN right, heated, Width 900 mm x Height 2100 mm
Observation window, heated, with blackout shutter and lockable: Width 500 mm x Height 600 mm
Feedthrough: 2x, right front side, Ø 75 mm
Irradiation unit, test chamber
Opening: 4x in left side wall for SC 2500, each 850 x 700 mm
Irradiated area when using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Refrigeration system: Bitzer compressor, semi-hermetic, 2-stage, air cooled
Condenser: split condenser (outdoor installation, winter control)
Refrigerant: R507 / R23
Temperature control system
Coolant medium Tyfocor / water
Mixing ratio 50/50%
Bodjklv H Ispfx Adiedc
Coolant density: 1.072 kg/dm³
Filling quantity: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply, test chamber
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type: hardwired
Max. simultaneous power demand: approx. 32.0 kW
Supply fuse: 3 x 63, Char C (A)
Power supply, SolarConstant
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type:
Max. simultaneous power demand: approx. 30.0 kW
Supply fuse: 3 x 63, Char C (A)
Overall external dimensions of the test cell including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber (total): approx. 2700 kg
Condenser empty weight: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Scope of delivery: (see picture)
(Technical data and information are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,623 km
Temperature cabinet 2240 liters
MytronT2240 –40°C bis +100°C
Call
Condition: used, mytron
Type: T2240
Water-cooled temperature chamber
Technical Data:
External dimensions: Width 1435 mm, Height 1955 mm, Depth 2590 mm
Test chamber dimensions: Width 1050 mm, Height 1400 mm, Depth 1600 mm
Test chamber volume: approx. 2240 l
Cable entry ports:
2 x 100 mm right
2 x 100 mm left
Temperature range: –40 °C to +100 °C at 23 °C ambient temperature
Temporal temperature constancy: +/- 0.5 °K
Spatial temperature constancy: +/- 1.0 °K
Cooling: water cooling
Inlet and outlet: 1" internal thread
Bdedpfxsvtl Hqe Adiec
Cooling water shut-off via solenoid valve when unit is OFF
Fault indicator for refrigeration unit errors
Cooling water consumption: inlet temperature approx. 15 °C, approx. 15 l/min,
outlet temperature approx. 22 °C (with continuous cooling approx. 27 °C)
Power connection: 3NPE AC 50 Hz 400 V, 32 A CEE plug
Power consumption: approx. 6.5 kVA
Fusing: 3 x 20.0 AT, 3 x 10.0 AT
Lighting: 25 watts each, left and right sides of test chamber
Exhaust connection: DN 100 mm plug-in system
Safety device: electronic over-temperature protection, fixed setting
Smoke detection with alarm sound
Viewing window: five-layer glass, 130 x 360 mm
Refrigerant: R 404 A, approx. 10 kg
Weight: approx. 850 kg
Condition: used
Scope of delivery: (see picture)
(Specifications subject to change and error!)
If you have further questions, we would be glad to answer them by phone.
Listing
Borken
7,623 km
Temperature chamber 986 liters
ThermotronSE-1000-6-6 -70°C bis + 180°C
Call
Condition: excellent (used), Here we offer you a Thermotron temperature chamber.
Water-cooled
Thermotron Temperature Chamber SE-1000-6-6
Internal dimensions (W x D x H): 1000 x 1000 x 980 mm
Working chamber volume: approx. 980 liters
Temperature range: -70ºC to 180ºC
Overall heating rate: approx. 4.1 K
Overall cooling rate: approx. 1.2 K
Heating capacity (°C/min) -65º to 71ºC: 6.8°C
Heating capacity (°C/min) -65º to 180ºC: 5.6°C
Heating capacity (°C/min) -40ºC to 85ºC: 6.5°C
Bdsdpfjixtitex Adioc
Cooling capacity (°C/min) 85ºC to -40ºC: 4.7°C
Cooling capacity (°C/min) 71ºC to -65ºC: 3.7°C
Cooling capacity (°C/min) 180ºC to -65ºC: 4.3°C
External dimensions (W x D x H): 1250 x 1900 x 2200 mm
Electrical requirements: 400V / 5P / N / PE, 35 A
Refrigerants: R508B and R404A
Approximate weight: 900 kg
Type: Thermotron SE-1000-6-6
Important information for you as a buyer:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Subject to change and errors in the technical data and information!)
If you have any further questions, we will be happy to assist you by phone.
Listing
Borken
7,623 km
Walk-in climate chamber with humidity control
RS-SimulatorenKKM 110/45 -40°C bis +120°C
Call
Condition: excellent (used), RS Simulators
Type: KKM 110/45
Manufacturer: RS Simulators, water-cooled
Climatic chamber 110 m³ incl. condenser unit
The KKM 110/45 model is part of the TKM/KKM modular system by RS Simulators—a modular climatic chamber that is assembled on-site.
This design offers:
Modularity: Individual segments are preassembled and set up at the customer’s location. This makes retrofitting (adding depth or expansion modules) and later relocation straightforward.
Technical specifications climatic chamber:
Manufacturer: RS-Simulatoren Prüf- und Messtechnik GmbH
Model: KKM 110/45
External dimensions: 6200 x 9400 x 3400 mm (W x D x H), incl. technical attachments
Internal dimensions: 5900 x 7000 x 2960 mm (W x D x H)
Chamber door (double-leaf): 3600 x 2930 mm (W x H)
Personnel door (single-leaf) in side wall: 1880 x 900 mm (H x W)
Feedthroughs: 8 x Ø120 mm (4x left & 4x right)
Bdodpfx Adewwg Uvjijc
Windows: 1x (460 x 550 mm) in front chamber door, heated
1x (1260 x 1000 mm) in left side wall, heated
Temperature range: -40°C to +120°C
Temperature fluctuation: ± 0.8K – 1.5K as per DIN 50011 with empty test area
Humidity range: 10% to 95%
Humidity tolerance: +/- 5.0%
Refrigerant: 2x R404A 52 kg
2x R23 17 kg
Temperature change rate:
Heating: 1.0 K/min
Cooling: 1.0 K/min
Electrical data:
Voltage: 3x400V/N/PE Current: 340A
Weight: approx. 2,000 kg
For your safety as a buyer, please note the following information!
The following points are always carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
7,614 km
Temperaturetestchamber 500L -40°C - 180°
WeissWT 11-18 KWP 500/40
Call
Year of construction: 1990, condition: good (used), Weiss temperature test chamber WT 11-18 KWP 500/40
Spring, summer, autumn and winter - your products must be able to withstand different temperatures during manufacture, transport, storage and use. The temperature test chambers from Weiss Technik help you to test the influence of thermal conditions on the properties, function and service life of your products.
Manufacturer: Weiss Technik
Type: KWP 500/40 - 180 DU
Designation: WT 11-18
Type: Temperature test chamber
Test chamber volume: 500 ltr.
Temperature range: -40°C to +180°C
Outside dimensions: 110 cm wide, 173 cm deep and 204 cm high
Dimensions inside: 80 cm wide, 85 cm deep and 85 cm high
Pressure: 25 bar
Voltage: 380 V
Frequency: 50 Hz
kVA: 4.7
Refrigerant: R 502
Year of manufacture: 1990
Condition: used
complete factory closure,
large selection of storage platforms, pallet racks, shelf racks, paternosters.
High-quality industrial machines, lathes, grinding machines, hand machines
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further articles - new and used - you will find in our shop!
International shipping costs on request!
Bedpfx Adsh Izh Ieijdc
Listing
Borken
7,623 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Bsdpfx Adsygvn Nsisdc
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Trust Seal
Dealers certified through Used-Machines

Listing
Borken
7,623 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
Bdedpfxoygutwo Adisc
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
7,623 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Bdedeygur Topfx Adiec
Listing
Borken
7,623 km
Temperature test chamber 350 liters
CTSTS-70/350 -70°C bis 180°C
Call
Condition: excellent (used), Here we offer you a temperature test chamber.
Water-cooled
Technical specifications:
Temperature operating range
Temperature range in °C: -70 / +180°C
Temperature change rate according to DIN 50 011, Part 12
Cooling rate: approx. 5 K/min
Heating rate: approx. 5 K/min
Dimensions:
Test volume: 350 liters
Test chamber dimensions (approx.): Height 750 mm, Width 650 mm, Depth 720 mm
External dimensions (approx.): Height 1800 mm, Width 850 mm, Depth 1640 mm
Operating data:
Electrical connection: 400 V, 3/N, 50 Hz
Nominal power: 13.3 kW
Refrigerant: R404A / R23
Bedpfxjygupre Adiodc
Weight: approx. 650 kg
Type: TS-70/350
Important safety information for buyers:
The following steps are performed on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. After successful inspection, the chambers undergo a test run, monitored with calibrated instruments.
Condition: used
Scope of delivery: (see picture)
(Specifications subject to change and error!)
Further questions can be answered by phone.
Listing
Borken
7,623 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS Climate Test Chamber T-70/600 Water-Cooled
Temperature Range: -70°C to +180°C
Rated Voltage: 400V 3/N PE 50 Hz
Rated Power: 6.7 kW
Rated Current: 10.2 A
Compressor: TFH2480Z/TFH2511Z, Refrigerant R23/R404A
Control System:
- Microprocessor-controlled regulation and monitoring system
- Simple, user-friendly terminal integrated into the door
- Digital display for set and actual temperature values
- Easy adjustment via +/- keys
- Digital input for temperature in °C
- PLC-compatible
- Up to 100 test programs possible
- RS 232 interface
- 2 free switching channels for user-side test specimen connections
Shelving:
Stainless steel, shelf area 820 x 710 mm
Bdsdpfx Adeygultsisc
Load capacity per shelf max. 35 kg
Total load capacity with full shelf configuration 100 kg
Cooling Unit:
Water-cooled, low-noise, fully hermetic, stepless power adjustment via electronic monitoring and control system,
environmentally friendly refrigerants R404A/R23
Temperature Testing:
Temperature range -70°C to +180°C
Temperature deviation ±0.1 to 10.3 K over time
Temperature change rate according to DIN 50 011, Part 12 measured at the center of the test chamber:
Heating: 2.5 K/min
Cooling: 2 K/min
Thermal radiation max. 1500 W at +20°C
Technical data refer to an ambient temperature of +25°C, rated voltage 400 V, without test specimen, without thermal radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x D x H)
External dimensions 1050 x 1850 x 1900 mm (W x D x H)
Operating Data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current 10.2 A
Protection class IP 22
Condensate drain non-pressurized, R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information reserved!)
Further questions can be answered by phone.
We make it easier for you to find: "espec pl-3kph -40°c bis 180°c"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time