Used Vötsch Vc 0150 for sale (696)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
VötschVT 7021
Call
Condition: excellent (used), Heraeus Vötsch
Type: VT 7021
Air-cooled temperature test chamber
1 port, nominal width 80 mm,
Test chamber volume: 210 liters
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (heating): 2.5 K/min
Temperature change rate (cooling): 2.5 K/min
Max. heat compensation: 800 W
Test chamber dimensions: Width 560 mm, Depth 570 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1250 mm, Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50 Hz
Rated power approx. 1.8 kW, rated current 12 A
Gksdpfx Aieziiw Ijxoa
Refrigerant: R404A and R23
Weight: 355 kg
For your safety as a buyer, please note the following information!
The following procedures are performed on the chambers we offer, in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors in the details!)
For further questions, please feel free to contact us by phone.
Listing
Dortmund
7,674 km
Chamber oven for solvent-based parts
VötschVTLF 160/150/110
Call
Condition: used, Year of construction: 2008, power: 27 kW (36.71 HP), input voltage: 400 V, input current: 44 A, temperature: 200 °C, inner dimension length: 1,100 mm, inner dimension width: 1,600 mm, inner dimension height: 1,500 mm, overall weight: 3,500 kg, number of chambers: 1, Equipment: CE marking, documentation/manual, Electrically heated chamber oven Vötsch VTLF 160/150/110 for components containing solvents.
Usable dimensions: 1600 x 1100 x 1500 mm (width x depth x height)
Rated temperature: 200 °C
Maximum permissible solvent quantity according to EN 1539 at rated temperature: 38 g
Total connected load: 30 kVA
Gsdpfxoy U Uzxj Aixoka
Rated power: 27 kW
Usable volume: 2.78 m³
Steam space: 4.5 m³
Listing
Borken
7,623 km
Temperature test chamber spray device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in the stabilized state
according to IEC 60068-3-5, depending on the test chamber temperature
± 1 K over time
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the support grid
Water level = 0 mm
Gkjdpfx Aiezh D S Roxoa
The water level is at the top edge of the support grid
Data for spray device, standard
Number of spray nozzles 6
Spray volume per nozzle 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles 6
Spray volume per nozzle 4.5 l/min
Additional flooding nozzles 2
Spray volume additional nozzle 6 l/min
Compressed air consumption approx. 3 m³/h
Data for water tank with preheating
Volume approx. 2000 l
Temperature range for preheating +5°C to +40°C
Temperature change duration
Cooling from +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Data for installation and operation:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Feedthroughs
1 feedthrough ∅ 50 mm, installed on the left
Test chamber volume: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Rated voltage 3/N/PE AC 400V ± 10% 50Hz
Rated power approx. 26 kW
Rated current approx. 44.0 A (neutral conductor loaded)
Fuse 63 A gG, on-site
Weight approx. 890 kg net
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Meiningen
7,909 km
Paint dryer DIN 1539 300°C
VötschVTL 100/150 nach DIN 1539
Call
Condition: refurbished (used), Year of construction: 2001, functionality: fully functional, Completely overhauled, 12-month warranty, available immediately.
Gedpovcb U Aefx Aixeka
Equipped with a safety system for solvent-based substances in accordance with DIN 1539, including exhaust fan, supply air cage filter, as well as concentration monitoring and a recirculation air filter wall in the interior.
- Internal dimensions (W x D x H): 1000 x 1000 x 1500 mm
- External dimensions (W x D x H): 1900 x 1430 x 2315 mm
- Capacity: 1500 liters
- Tmax: 300°C
- Eurotherm controller 2404 (20 programs, each with 16 segments)
- Eurotherm recorder
- Connected load: 29 kW
- 6 wire shelves included, plus V2A support brackets
- Minimum exhaust air flow rate: 360 m³/h
- Maximum permissible solvent quantity: 36g at nominal temperature of 300°C
- With concentration monitoring
- New window seals
- Net weight approx. 1200 kg
- Includes documentation, CE declaration
- Electrically tested and with DGUV test protocol
Inspection in our warehouse by appointment.
We offer new and used industrial ovens. Get in touch with us!
Oven, ovens, drying oven, furnace, heat oven, heating cabinet, industrial oven, paint dryer, annealing oven, heating oven, tempering oven, drying cabinet, chamber oven, baking oven, recirculation drying cabinet, recirculation oven, solvent oven, chamber recirculation oven
Listing
Wymysłów
8,235 km
Vötsch VT 7004 – climatic chamber / temperature chamber
Vötsch VT 7004 – komora klimatyczna / komora temperaturowaVötsch VT 7004 – komora klimatyczna / komora temperaturowa
Call
Condition: excellent (used), For sale: a Vötsch VT 7004 climate chamber, designed for precise research and testing under controlled temperature conditions. This unit is suitable for use in laboratories, quality control departments, materials research, electronics, and the automotive industry.
The chamber is equipped with an electronic temperature controller, an efficient cooling system, and a forced air circulation system that ensures uniform temperature distribution throughout the working chamber. The interior is made of stainless steel, which facilitates cleaning and ensures high durability.
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Model: VT 7004
Year of manufacture: 2000
Device number: 58566024350010
Power supply: 230 V AC, 50 Hz
Rated power: 2.0 kW
Rated current: 10 A
Refrigerant:
R404A – 0.7 kg
R23 – 0.22 kg
Maximum working pressure: 25 bar
Interior: stainless steel
Electronic temperature controller
Forced air circulation
Door with silicone seal
Lighting and service access port in the chamber
Compact design
Condition:
Used unit.
Visually in good condition.
Gkjdpfx Aiezi U Tnexea
The chamber is clean and complete.
Sold in the exact condition as shown in the pictures.
Listing
Wymysłów
8,235 km
Vötsch VTL 7010 – climate chamber / temperature test chamber
Vötsch VTL 7010 – komora klimatyczna / komora do badań temperaturowychVötsch VTL 7010 – komora klimatyczna / komora do badań temperaturowych
Call
Condition: excellent (used), For sale is a professional Vötsch VTL 7010 climate chamber, designed for conducting temperature tests and simulating environmental conditions. The device is used in laboratories, quality control departments, research and development centers, and for testing electronic, automotive, and mechanical components.
The chamber is in good working order – the touchscreen starts up correctly and displays the main menu and the current operating temperature, as confirmed by the photos.
Technical specifications:
Manufacturer: Vötsch Industrietechnik GmbH
Model: VTL 7010
Gksdpfezi T Nhex Aixoa
Year of manufacture: 2010
Temperature range: -70°C to +180°C
Heating/cooling rate: approx. 3.5 K/min
Refrigerant:
R404A – 0.8 kg
R23 – 0.2 kg
Power supply: 230 V AC, 50 Hz
Rated power: 3.5 kW
Rated current: 15.2 A
Operating pressure: 8 bar
Control via a color touchscreen
Working chamber made of stainless steel
Door with a viewing window
Adjustable internal shelves
CE marking
Applications
The device is ideally suited for:
temperature tests,
material testing,
testing electronics and components,
durability tests,
quality control,
research and development work.
Condition:
used,
functional,
control panel operates correctly,
internal chamber is clean and well-maintained,
normal signs of wear and tear,
sold exactly as shown in the pictures.
Included:
Vötsch VTL 7010 climate chamber,
2 perforated shelves,
built-in control panel.
Listing
Borken
7,623 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temperature Deviation (temporal): ±0.1 to ±0.5 K
Temperature Deviation (spatial): ±0.5 to ±2.0 K
Temperature Change Rate (cooling): 5.0 K/min
Temperature Change Rate (heating): 6.5 K/min
Heat Compensation at +20°C: 3000 W
Heat Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 liters
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Level at 1m Distance (Free-Field Measurement): < 69dB (A)
Side Feedthrough: 5.5 cm / 12.5 cm
Chamber is water-cooled.
Refrigerant: R-404A and R-23
Gjdpfx Aiozg Tp Nsxoka
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components.
2. New filling with legally compliant refrigerant.
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of Delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Testing Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temperature Deviation (Temporal): ± 0.1 to ± 0.5 K
Temperature Deviation (Spatial): ± 0.5 to ± 2.0 K
Temperature Change Rate (Cooling): 5.0 K/min
Temperature Change Rate (Heating): 6.5 K/min
Heat Compensation at +20°C: 3000 W
Heat Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 Liters
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Pressure Level at 1m Distance (Free-Field Measurement): < 69dB (A)
Side Opening: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R-404A and R-23
Weight: Approximately 570 kg
Gedpfx Aiezg Tp Ajxska
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerants
3. After successful inspection, the chambers will be subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of Supply: (See Image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Dryer for coating materials
VötschLTU 60/60
Call
Condition: excellent (used), Vötsch
Type: LTU 60/60
Heraeus Vötsch dryer for coating materials
Maximum concentration of flammable substances: 40% of the lower explosive limit (LEL)
Maximum temperature of the heating surface: over 750 °C
Godpfx Aozg Tpvjixoka
Device description:
Technical data:
Internal volume (usable volume): 0.216 m3
Internal dimensions: Width 600 mm, Height 600 mm, Depth 600 mm
External dimensions: Overall width 796 mm, Height 1725 mm, Depth 850 mm
Load capacity / Payload
Total roller track capacity: 55 kg
Loading height above the installation floor: 820 mm
Weight (net): 275 kg
Minimum exhaust air volume flow: 96 m3/h
Purge time (5 air changes): 90 sec.
Recirculation volume flow (enhanced): 33 m3/h
Total steam volume: 0.414 m3
Sound pressure level (according to DIN 45635): < 70 dB(A)
Cut-out temperature
Temperature limiter (TL) fixed at 300 °C
Temperature selector limiter (TSL) adjustable above the rated temperature: 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TL): 1
Temperature selector limiter (TSL): 2
Rated temperature: 200 °C
Electrical data
Rated voltage / Frequency: 400V, 3/(N)PE, AC 50/60 Hz
Rated current: 12.0 A
Rated power: 6.0 kW
Connected load: 7.0 kW
Weight: 275 kg
Condition: used
Scope of supply: (See image)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Dryer for coating materials
VötschLTU 60/60
Call
Condition: excellent (used), Vötsch
Type: LTU 60/60
Heraeus Vötsch dryer for coating materials
Maximum concentration of flammable substances: 40% of the lower explosive limit (LEL)
Maximum temperature of the heating surface: over 750 °C
Device description:
Technical data:
Internal volume (usable volume): 0.216 m3
Internal dimensions: width 600 mm, height 600 mm, depth 600 mm
External dimensions: overall width 796 mm, height 1725 mm, depth 850 mm
Load capacity / payload
Total roller track capacity: 55 kg
Loading height above the installation floor: 820 mm
Weight (net): 275 kg
Minimum exhaust air flow rate: 96 m3/h
Purge time (5 air changes): 90 seconds
Enhanced recirculation air flow rate: 33 m3/h
Total steam volume: 0.414 m3
Sound pressure level (according to DIN 45635): < 70 dB(A)
Cut-out temperature
Temperature limiter (TL) fixed setting: 300 °C
Adjustable temperature selector (ATS) adjustable above the rated temperature: 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TL): 1
Adjustable temperature selector (ATS): 2
Rated temperature: 200 °C
Electrical data
Rated voltage / frequency: 400V, 3/(N)PE, AC 50/60 Hz
Rated current: 12.0 A
Rated power: 6.0 kW
Connected load: 7.0 kW
Gsdpjzg Tppsfx Aixjka
Weight: 275 kg
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Gsdpfozg Tpijx Aixoka
Temperature Range: -70°C to +180°C
Temporal Temperature Deviation: ± 0.1 to ± 0.5 K
Spatial Temperature Deviation: ± 0.5 to ± 2.0 K
Temperature Change Rate (Cooling): 5.0 K/min
Temperature Change Rate (Heating): 6.5 K/min
Thermal Compensation at +20°C: 3000 W
Thermal Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 liters
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Level at 1m Distance (Free Field Measurement): < 69dB (A)
Side Access: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R-404A and R-23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with refrigerants compliant with legal regulations
3. After successful inspection, the chambers undergo a test run, which is monitored with calibrated equipment.
Condition: used
Scope of Supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature cabinet
VötschVTS 7011-5
Call
Condition: good (used), Vötsch
Type: VTS 7011-5
Heraeus Vötsch temperature control chamber, water-cooled
Test chamber volume: 110 liters
Test chamber dimensions: width 560 mm, depth 350 mm, height 630 mm
External dimensions: width 850 mm, depth 1030 mm, height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.3 to 1 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Gksdpfxszg Tpcs Aixsa
Temperature change rate (cooling): 6 K/min
Temperature change rate (heating): 10 K/min
Refrigerant: R-404 A / R 23
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 7.5 kW
Rated current: 13 A
Weight: 360 kg
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature testing chamber, water-cooled
Performance data:
With a temperature change rate of 25 K/min
Test chamber dimensions: height 750 mm, width 580 mm, depth 615 mm
External dimensions: height 1775 mm, width 780 mm, depth 1895 mm
Temperature range: -72°C to +180°C
Temperature deviation (over time): ± 0.1 to ± 0.5
Temperature homogeneity (spatial): ± 0.5 to ± 2.0
Temperature change rate (cooling): 25 K/min
Temperature change rate (heating): 25 K/min
Heat compensation at -20°C: 8000 W
Heat compensation at +20°C: 8000 W
Test volume: 270 liters
2x side ports, diameter 125 cm
1x side port, diameter 50 cm
Chamber is water-cooled
Test chamber lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Gsdpfszg Eygox Aixoka
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 26 KW
Rated current: 44 A
Refrigerant: R-452A and R-23
Weight: approx. 980 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data and specifications are reserved!)
We will gladly answer any further questions you may have by phone.
Listing
Eindhoven
7,564 km
Climate test chamber
Vötsch/WeissGTTS 220
Call
Condition: used, Year of construction: 1980, functionality: unexamined, machine/vehicle number: GTTS 220, total height: 144 mm, total length: 135 mm, total width: 96 mm, Equipment: documentation/manual, Used Votsch/Weiss GTTS 220 Climate Chamber
Manufacturer: Votsch/Weiss
Model: GTTS 220 | 20
External dimensions: 135cm x 96cm x 144cm (length x width x height)
Gsdpfx Ajx H N Drjixjka
Max internal dimensions: 65cm x 92cm x 54/40cm (width x depth x height)
Voltage: 220/380 V
Refrigerant type: R12
Includes manual (installation and operation handbook)
Listing
Borken
7,623 km
Temperature test chest 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, condition: excellent (used), Here, we offer a Heraeus Vötsch temperature testing chamber.
Vötsch temperature testing chamber, test cabinet VLM 3068/S, air-cooled
(top-loading test chambers for construction materials)
Control panel
The control panel is mounted on a console on the temperature testing chamber. All control and operating commands can be initiated by simply touching the function symbols. The operating manual for the control panel is included.
Main switch
The main switch is located at the front of the temperature testing chamber.
Air handling unit
The air handling unit is located in the test chamber and contains the components necessary for temperature control.
In the air handling unit, the air is conditioned (cooled/heated) and circulated through the test chamber by the test chamber fan. The air is drawn in at the center of the side wall and re-enters the test chamber via the air guide plates on the long sides.
Feedthroughs
The temperature testing chamber can optionally be equipped with feedthroughs. These allow cables and testing equipment to be placed in the test chamber.
Feedthrough at the front: 2 x 82 mm diameter, at the rear: 1 x 85 mm diameter
Internal dimensions: width 2000 mm, depth 570 mm, height 600 mm
External dimensions: width 3000 mm, depth 870 mm, height 1060 mm
Technical data:
Data for mechanical load:
max. load with test specimen
Test chamber floor
(evenly distributed over the area) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Rated voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW, rated current 9 A
Fuse on customer side: 16A, slow-blow
Temperature testing chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement: sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Gksdpfx Aijzgbmisxea
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 900 mm x Depth 1550 mm x Height 1850 mm
Temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: Cooling 7.5 K/min
Test chamber volume: 190 liters
Rated voltage: 400 V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Gkedpfx Aiezfg Ucoxsa
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are reserved!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch Shock Test Chamber
Here we offer you a Vötsch shock test chamber.
Water-cooled
Temperature range: -80°C to +220°C
Gkedpfezd Uzuex Aixja
Warm chamber: +50 to +220
Intermediate chamber: -10 to +90
Cold chamber: -80 to +70
Supply voltage: 400V ±10% 3/N 50Hz
Rated current: 30.5 A
Rated power: 13.5 kW
Refrigerant VK: R 404A 3.00 kg p*: 25 bar
Refrigerant TK: R23 15 bar p*: 25 bar
Condition: used
Type: VT 7012 S3
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Temperature test chamber
Heraeus VötschVTS 7033
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer a Heraeus Vötsch temperature test chamber.
Gjdpszd Sf Dsfx Aixeka
Vötsch Temperature Test Chamber VTS 7033, Water-Cooled
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.5 K
Spatial temperature deviation: ± 1.5 K
Heating rate: 7.5 K/min
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x Depth 800 mm x Height 870 mm
Housing dimensions: 1080 mm x 1710 mm x 1950 mm
Side openings: 12 cm and 13 cm
Voltage: 400V +6/-10%, 3/N, 50Hz
Rated power: 9.5 kW, Rated current: 22 A
Refrigerant: R404A / R23
Approx. 570 liters, Weight: 580 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Type: VTS 7033
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature test chamber 335 liters
VötschVTS 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Heraeus Vötsch Temperature Test Chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW, Rated current: 21 A
Gksdpfx Aszd R Tgsixoa
Sound level at 1m distance (free-field measurement) < 69dB (A)
Side feedthrough: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R 452A and R 23
Weight: approx. 570 kg
Type: VTS 7034-5
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Dryer for coating materials
VötschLTU 60/60 LTU 60/60 200 °C
Call
Condition: excellent (used), Here we offer a Heraeus Vöstch dryer for coating materials.
Maximum concentration of flammable substances: < 40% of the lower explosive limit (LEL).
Maximum temperature of the heating surface: over 750 °C.
Device description:
Technical data:
Internal volume (usable volume): 0.216 m3
Internal dimensions: width 600 mm, height 600 mm, depth 600 mm
External dimensions: overall width 796 mm, height 1725 mm, depth 850 mm
Load capacity:
Total roller track capacity: 55 kg
Loading height above the installation floor: 820 mm
Weight (net): 275 kg
Minimum exhaust air flow rate: 96 m3/h
Purge time (5 air changes): 90 sec.
Enhanced recirculating air flow rate: 33 m3/h
Total steam space: 0.414 m3
Sound pressure level (according to DIN 45635): < 70 dB(A)
Cut-out temperature:
Temperature limiter (TB) fixed at 300 °C
Temperature selector limiter (TWB) adjustable above the nominal temperature by 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB): 1
Temperature selector limiter (TWB): 2
Nominal temperature: 200 °C
Electrical data:
Rated voltage / frequency: 400V, 3/(N)PE, AC 50/60Hz
Rated current: 12.0 A, rated power: 6.0 kW, connected load: 7.0 kW
Weight: 275 kg
Type: LTU 60/60
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
Gedpfx Aiszd Rrcexjka
We are happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature control chamber.
Heraeus Vötsch temperature control chamber, water-cooled
Test chamber volume: 110 liters
Test chamber dimensions: Width 560 mm, Depth 350 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1030 mm, Height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temperature gradient: 1 to 3 K
Gjdpfxszdtd Is Aixska
Temperature change rate (cooling): 3.2 K/min
Temperature change rate (heating): 3.5 K/min
Refrigerant: R-404 A / R 23
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 1.8 kW
Rated current: 12 A
Type: VT 7011
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Trust Seal
Dealers certified through Used-Machines

Listing
Borken
7,623 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature testing chamber.
Heraeus Vötsch temperature testing chamber, water-cooled
Temperature range: -70°C to +180°C
Temperature deviation (time-related): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 7.5 K/min
Temperature change rate (heating): 7.5 K/min
Thermal compensation +20°C: 3000 W
Thermal compensation -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Observation window:
Width 300 mm x Height 540 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 10.5 kW, Rated current: 22 A
Fuse, on customer side: 32 A, slow-blow
Sound pressure level at 1 m distance (free-field measurement): < 69 dB(A)
Side access: 50 cm / 125 cm
Chamber is water-cooled
Refrigerant: R 404A and R 23
Weight: approx. 460 kg
Type: VTS 7018-5
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with refrigerants that comply with legal regulations
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Gjdpfx Aiozdtdhsxeka
Listing
Borken
7,623 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch Temperature Shock Testing Chamber
Type: VT 7012 S2
Manufacturer: Vötsch Industrietechnik GmbH
Design: Water-cooled
For sale is a two-chamber temperature shock testing chamber from Vötsch, designed for rapid temperature change tests. Suitable for industrial, automotive, aerospace, as well as research and development applications.
Temperature Ranges:
Hot Chamber: +50 °C to +220 °C
Cold Chamber: -80 °C to +70 °C
Temperature Data:
Temporal temperature deviation: ±1 K
Spatial temperature deviation: ±2 K
Heating rate, hot chamber: approx. 11 K/min
Heating rate, cold chamber: approx. 2 K/min
Cooling rate: approx. 3 K/min
Test Chamber:
Volume: approx. 125 liters
Internal dimensions: approx. 470 x 650 x 410 mm
Cable entry: Ø 67 mm
Electrical Data:
Connection: 3/N/PE AC 400 V ±10% / 50 Hz
Rated power: approx. 10 kW
Rated current: approx. 25 A
Refrigerant:
R404A: 2.9 kg
R23: 1.27 kg
Pressure Data:
Gkodpfx Aioy Iyuwsxsa
ND max.: 22.5 bar
HD max.: 25 bar
Dimensions:
approx. 930 x 2115 x 1970 mm
Weight:
approx. 1000 kg
Equipment:
Two-chamber shock testing system
Digital control
Program operation
Observation window
Cable entry
Condition:
Used
Optical condition as shown in the pictures
Normal storage and usage marks present
Scope of delivery:
Vötsch VT 7012 S2 temperature shock testing chamber
Accessories as shown in the pictures
Important Note:
All information has been provided to the best of our knowledge based on the pictures, nameplates, and manufacturer information.
Shipping is possible.
Subject to changes, errors and prior sale.
We are happy to answer any further questions by phone.
Listing
Borken
7,623 km
Oven
VötschNTU 60/60
Call
Year of construction: 1996, condition: good (used), Here we offer a Voetsch drying cabinet, heating cabinet, and heat oven.
Voetsch NTU 60/60 250°C
Nominal temperature: 250°C
Connection voltage:
400 V 3 (N) PE AC, 50/60 Hz
Internal dimensions: Width 600 mm / Height 600 mm / Depth 600 mm
External dimensions: Width 1000 mm / Height 1675 mm / Depth 1300 mm
Forced air circulation fan
Type: Voetsch NTU 60/60
Gsdpjzdiyhofx Aixjka
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Root
8,011 km
Vacuum machine
VC 99907S
Call
Condition: good (used), Vacuum packaging machine.
Gkjdpfjwt Tmksx Aixja
We make it easier for you to find: "vötsch vc 0150"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time