Used Chamber Tempering Furnace for sale (3,015)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Temperature test chamber, explosion-proof
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Ncjdpfezd Rzwox Ac Teu
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Listing
Borken
7,623 km
Temperature chamber
WEISSWT1-340/30
Call
Condition: excellent (used), Weiss Temperature Chamber
Here we offer a Weiss temperature chamber.
Converted to R452a
Weiss Temperature Chamber, Air-Cooled
Temperature range: from -30°C to 180°C
Temperature change rate, cooling: 1.6 K/min
Temperature change rate, heating: 2.1 K/min
Test chamber dimensions: width 550 mm x depth 750 mm x height 800 mm
Housing dimensions: width 800 mm x depth 1500 mm x height 1800 mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 4.9 kW, rated current: 9 A
Refrigerant: R452a
Weight: 515 kg
Type: WT1-340/30
For your safety as a buyer, please note the following information:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
Ncjdszd Rw Sjpfx Ac Tsu
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Type: VCS 7034-5
Climate Test Chamber Water-Cooled
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 3.5 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3,000 W / at -20°C: 3,000 W
Temperature calibration points: +23°C and +80°C
Nodpoxufypofx Ac Tocu
Performance for climate tests:
Temperature range: +10 to +95°C
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Humidity deviation over time: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climatic calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions:
Width: 580 mm, Depth: 765 mm, Height: 750 mm
External dimensions:
Width: 870 mm, Depth: 1595 mm, Height: 1775 mm
Feedthroughs:
1 x approx. 50 mm Ø, left side
2 x approx. 125 mm Ø, left side
1 x approx. 125 mm Ø, right side
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R404A / R-23
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing
Borken
7,623 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature testing chamber.
Heraeus Vötsch temperature testing chamber, water-cooled
Temperature range: -70°C to +180°C
Temperature deviation (time-related): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 7.5 K/min
Temperature change rate (heating): 7.5 K/min
Thermal compensation +20°C: 3000 W
Thermal compensation -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Observation window:
Width 300 mm x Height 540 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 10.5 kW, Rated current: 22 A
Fuse, on customer side: 32 A, slow-blow
Sound pressure level at 1 m distance (free-field measurement): < 69 dB(A)
Side access: 50 cm / 125 cm
Nodszdtdhepfx Ac Tscu
Chamber is water-cooled
Refrigerant: R 404A and R 23
Weight: approx. 460 kg
Type: VTS 7018-5
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with refrigerants that comply with legal regulations
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature test chamber
RS-SimulatorenTS 150/45 (50)
Call
Condition: excellent (used), RS Simulators
Here we offer a temperature testing chamber.
Air-cooled
Temperature range: -50°C to +100°C
Test chamber dimensions: Width 520 mm x Height 520 mm x Depth 500 mm
External dimensions: Width 820 mm x Height 1750 mm x Depth 1300 mm
Power consumption: 13.5 A
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 800 kg
Type: TS 150/45 (50)
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
Nedpfjzdtc Rox Ac Tscu
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature shock chamber 580 liters
RS-SimulatorenST2K 1000/55 -70°C bis +180°C
Call
Condition: excellent (used), RS-Simulators Temperature Shock System ST2K 1000 / 55
The system was regularly serviced and maintained by the manufacturer until it was decommissioned.
Device Data
Manufacturer: RS-Simulators
Type: ST2K 1000 / 55
Design: Temperature Shock System
Cooling: water-cooled
Description
Used temperature shock system for standard-compliant thermal shock testing.
Suitable for material, component, and reliability testing.
Application in industry, automotive, research, and quality assurance.
System Description
2 separate temperature chambers (hot / cold)
Automatic horizontal test basket transfer
Fast changeover for temperature shock tests
Temperature ranges
Hot chamber: +40 °C to +180 °C
Cold chamber: -70 °C to +100 °C
Time deviation: ±0.8 K
Test chamber
Volume: approx. 580 liters
Internal (W x H x D): approx. 1070 x 680 x 800 mm
Max. load: approx. 150 kg
Power supply
400 V / 3~ / N / PE / 50 Hz
Power: max. 33 kVA
Current consumption: max. 65 A
Media connections
Cooling water: G 1", approx. 3 bar (max. 10 bar)
Cooling water requirement: max. 3.2 m³/h
Cooling water return: unpressurized
Compressed air: NW 7.2, 4–10.5 bar
Dimensions:
External (W x H x D): approx. 2800 x 2400 x 2200 mm
Weight: approx. 2800 kg
Equipment:
Horizontal basket movement
C-rails in the test chamber
Large test basket (>1000 mm)
Observation window
Internal lighting
Controller SE-604
Program operation and data logging
RS232 interface
Refrigeration system
Refrigerant: R449A / R23
R449A: approx. 8.0 kg
R23: approx. 2.5 kg
Operating data:
Operating hours: approx. 4,500 hours
Sound level: approx. 67 dB(A)
Environmental conditions
Temperature: +12 °C to +30 °C
Humidity: 25 % to 75 % rel. humidity
Scope of supply:
RS-Simulators Temperature Shock System ST2K 1000 / 55
Scope of supply as shown in the pictures
Functional test
Refrigerant service
Nsdpfx Acoy H Igfj Tecu
Leakage test
Condition: Used.
Condition: see pictures.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to changes and prior sale.
If you have any questions, please contact us.
Listing
Borken
7,623 km
Climatic chamber temperature and humidity
EspecPL-3KPH -40°C bis 180°C
Call
Condition: good (used), ESPEC Climate Testing Chamber PL-3KPH
Manufacturer: ESPEC Corp.
Type: PL-3KPH
Design: Air-cooled temperature and climate testing chamber
For sale is a used ESPEC climate testing chamber for temperature and climate testing in research, development, quality assurance, and industry.
Technical data:
Test chamber volume: approx. 400 liters
Temperature range: approx. -40 °C to +180 °C
Humidity range: approx. 20 % to 98 % RH
Internal dimensions (W x H x D): approx. 600 × 850 × 800 mm
External dimensions (W x H x D): approx. 1010 × 1690 × 1195 mm
Electrical connection: AC 400 V / 3~ / 50 Hz
Max. power consumption: approx. 11 A
Weight: approx. 350 kg
Cooling: air-cooled
No external water connection required
Refrigerant according to label:
R452A – approx. 1.2 kg
Features:
Touchscreen control
Programmed and constant operation
Temperature and humidity control
Observation window in the door
Stainless steel test chamber
Interior lighting / Chamber Lamp
Side cable/pipe passage Ø approx. 100 mm
Overheat protection
Hour counter integrated
RS-232C interface
Water tank system
Specimen Power Supply Control
Time Signal connection
Condition:
Used unit with signs of age and wear.
Some rust and corrosion spots are present in the lower housing area.
Interior with signs of use.
Ncsdpfx Aey N Awqoc Tju
Optical condition, see pictures.
Scope of delivery:
ESPEC Climate Testing Chamber PL-3KPH
Shelf included
Scope of delivery as shown in the pictures
Service:
Functional check and replacement of necessary components
Refilling with legally compliant refrigerant if required
Leak test with certificate
Notes:
Inspection possible by arrangement.
Loading can be organized.
Commercial sale
Important note:
All information has been provided to the best of our knowledge based on the pictures, nameplates and manufacturer information.
Shipping possible.
Subject to change, errors and prior sale.
We are happy to answer any further questions by telephone.
Listing
Borken
7,623 km
Temperature test chamber
RS-SimulatorenTS 600/45 EX
Call
Condition: excellent (used), RS Simulators
We offer a test cabinet here.
Water-cooled
Temperature range: -40°C to +180°C
Test chamber dimensions: 850mm x 850mm x 800 mm (W x H x D)
External dimensions: 1100mm x 1850mm x 1500mm (W x H x D)
Power consumption: 13.5 A
Refrigerant: R404A
Connection voltage: 3x400V/N/PE 9A
Weight: approx. 750kg
Type: TS 600/45
Nodpjzdn Stsfx Ac Tecu
Explosion-proof operation not tested
However, max. 160°C in this condition
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature shock test chamber
CTSTSS-70/32 -80°C bis +200°C
Call
Condition: excellent (used), CTS Temperature Shock Test Chamber
Type: TSS-70/32
Manufacturer: CTS Klima Temperatur Systeme
Design: Air-cooled
For sale is a CTS temperature shock test chamber for temperature change and shock testing in industry, research, and development.
Technical data:
Test chamber volume: approx. 32 liters
Max. test specimen weight: approx. 10 kg
Temperature ranges:
Hot chamber: +50 °C to +200 °C
Cold chamber: -80 °C to +100 °C
Performance data:
Heating rate: approx. 6 K/min
Cooling rate: approx. 6 K/min
Temperature change rate: up to approx. 100 K/min
Changeover time: < 10 seconds
Temperature deviation: ±1 K / ±2 K
Electrical data:
Connection: 400 V / 3/N / 50 Hz
Rated power: approx. 9.7 kW
Rated current: approx. 15.4 A
Fuse: 16 A slow-blow
Protection class: IP 22
Refrigerant:
R404A: 2.3 kg / R23: 0.90 kg
Pressure data:
Operating overpressure: 25 bar
Test pressure: 27.5 bar
Dimensions: approx. 1325 x 2012 x 1820–2020 mm (W x D x H)
Weight: approx. 650 kg
Further data:
Sound pressure level: < 58 dB(A)
Compressed air connection: 1/4" male
Equipment:
Two-chamber system (hot / cold chamber)
Digital CTS control
Display / control panel
Program operation
Operating hour counter
Observation window
Interior lighting
Temperature limiter
Test specimen protection
RS232 interface
Documentation:
Declaration of conformity available
Test certificates available
Operating manual available
Wiring diagram available
Piping diagram available
Quick start guide available
Safety data sheets available
Note:
The table shown in the photos is not included in the sale.
Ncsdpey I Ntcsfx Ac Tou
Condition:
Used
Optical condition see pictures
Scope of supply as shown in the pictures
Inspection possible by appointment.
Loading can be organized.
Commercial sale
(Changes and errors in the technical data and information are reserved!)
We will be happy to answer any further questions you may have by telephone.
Listing
Kölleda
7,910 km
Temperature chamber - 70°C to 180°C
WEISSWT11-270/70/10
Call
Year of construction: 2001, condition: ready for operation (used), functionality: fully functional, machine/vehicle number: 58226018400020, Weiss Temperature Chamber
Type: WT11-270/70/10
Section No.: 58226018400020
Control: Simcon/32-NET Version: 00.1902
Ports: Left (2x) NW 50 mm, Right (3x) NW 125 mm
Temperature Range: -70°C to 180°C
Test Chamber Volume: 270 liters
Door with window, interior lighting
Water-cooled temperature chamber
Compressed air dryer type: ZANDER
Ncedpfx Acev T Tncj Tju
Temperature change rate cooling: 10 K/min
Temperature change rate heating: 10.0 K/min
Temperature deviation over time ± 0.1 to ± 0.5 K
Temperature homogeneity over space ± 0.5 to ± 2.0 K
Test Chamber Dimensions: Width 580 mm x Depth 615 mm x Height 750 mm
Housing dimensions: Width 895 mm x Depth 2080 mm x Height 1950 mm
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 14 kW, Rated current 26 A
Refrigerant: R-404A/R-23
Listing
Borken
7,623 km
Temperature test chamber 25 liters
CTST-40/25 -40°C bis +180°C
Call
Condition: excellent (used), CTS Temperature Test Chamber T-40/25
Technical Data
Manufacturer: CTS Clima Temperatur Systeme
Type: T-40/25
Temperature Range: -40 °C to +180 °C
Test Chamber Volume: 25 liters
Temperature Change Rate:
Heating: 8.0 K/min
Cooling: 6.5 K/min
Temperature Deviation over Time:
±0.5 to ±1 K
Test Chamber Dimensions (W x D x H):
350 x 240 x 300 mm
External Dimensions (W x D x H):
595 x 580 x 860 mm
Electrical Data:
Rated Voltage: 230 V 1/N 50 Hz
Rated Power: 1.86 kW
Rated Current: 8.53 A
Protection Class: IP20
Refrigerant: R404A
Filling Quantity: 0.8 kg
Operating Pressure: 25 bar
Test Pressure: 20 bar
Features:
LCD control panel
Digital setpoint/actual value display
RS232 interface
Stainless steel test chamber material 1.4301
Window 200 x 200 mm
Lockable door
Air-cooled refrigeration unit
EASYLog data logger
3 stainless steel shelves
Weight: approx. 90 kg
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. Documented test run after successful inspection
Condition: used
Scope of supply: (See picture)
Inspection possible by appointment.
Loading can be arranged.
Nedozcxmtepfx Ac Tscu
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,614 km
Temperature chamber -40°C/+160°C
Zwick / Roell RS-SimulatorenTEE160/LN2 40S
Call
Condition: good (used), ZwickRoell Temperature Chamber for AllroundLine
Model: TEE160/LN2 40S
The TEE160/LN2 40S is a specialized temperature chamber designed primarily for material testing in combination with ZwickRoell testing machines (specifically the AllroundLine).
Flexible Application
ZwickRoell’s innovative temperature chamber ensures a flexible testing system tailored to customer needs—without compromise.
This guarantees reliable test results well into the future.
The safety door function ensures operator protection in compliance with European safety regulations.
The chamber door serves as a safety door with an interlocking mechanism.
Precise Temperature Control
The temperature chamber creates extremely uniform and precise conditions for specimens throughout the entire chamber volume.
This ensures accurate and repeatable test results.
Key Specifications
Temperature range: -40°C to +160°C.
Cooling system: Liquid nitrogen (LN2) for rapid cooling rates.
Temperature Chamber for AllroundLine
Application: Specifically designed for integration into materials testing machines to perform mechanical tests (e.g., tensile or compression tests) under controlled environmental conditions.
All panels in the door area (interior and exterior) are made of stainless steel. Dismountable heavy-duty base frame
Dimensions:
W x D x H = 1400 x 600 x 800 mm
Chamber:
W x D x H = 440 x 530 x 650 mm
Test opening: 110 mm
Power supply: 400/230 V, 16 A, 3N~, 50/60 Hz
Cooling via LN2 (liquid nitrogen)
"Everything from a single source: We would be happy to offer you suitable bank financing for your project."
komplett-konzept.leasingo.de
Find more items—new and used—in our shop!
International shipping costs on request!
Ncedpozcpwpsfx Ac Tju
Listing
Borken
7,623 km
Temperature test chamber 15 K/min
Weiss -70°C +180°CWT-1300/70/15 1340 Liter
Call
Condition: excellent (used), Weiss WT-1300/70/15 Temperature Testing Chamber
Manufacturer: Weiss Umwelttechnik GmbH
Type: WT-1300/70/15
Water-cooled temperature testing chamber with touch panel control for temperature tests in research, development, quality assurance, and industry.
Technical Data
Temperature range: -70 °C to +180 °C
Test chamber volume: approx. 1340 liters
Temperature change rate (heating): 15 K/min
Temperature change rate (cooling): 10 K/min
Temperature deviation (over time): ± 0.1 to ± 0.5 K
Temperature homogeneity (spatial): ± 0.5 to ± 2 K
Test chamber dimensions:
Height 920 mm
Width 1100 mm
Depth 1330 mm
External dimensions:
Height approx. 2050 mm
Width approx. 1300 mm
Depth approx. 3200 mm
Permissible test specimen load:
Test chamber floor: 150 kg
Insert shelf: 50 kg
Electrical Data
Rated voltage: 3/N/PE AC 400 V ±10 % 50 Hz
Rated current: 63 A
Rated power: 44 kW
Refrigeration System
Refrigerant R404A: 14.0 kg
Refrigerant R23: 5.4 kg
R404A LP max.: 18 bar
R404A HP max.: 25 bar
R23 LP max.: 19 bar
R23 HP max.: 25 bar
Standing pressure: 18.5 bar
Equipment
Touch panel control
Stainless steel test chamber
Multiple insertion levels
Side access port
Heated door seal
Water-cooled refrigeration unit
CEE connection
CE marking
Weight: approx. 1500 kg
Condition
Used equipment from industrial application.
Optical condition as shown in the pictures.
For the safety of our customers, the following work will be carried out on the offered climate chambers beforehand:
Njdpfx Aceza Dv Io Tocu
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Scope of delivery: see pictures
Shipping or freight transport possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by telephone.
Listing
Schwäbisch Gmünd
7,986 km
High-temperature furnace HTL 04/18
ThermconceptHochtemperaturofen HTL 04/18
Call
Year of construction: 2013, condition: ready for operation (used), functionality: fully functional, - Compact tabletop model with user-friendly, parallel upward-opening door
Ncjdoytr Ekopfx Ac Teu
- Double-walled housing with blower cooling, low external surface temperature
- Furnace insulation made of low thermal mass alumina material, allowing for rapid heating and cooling
- High-quality heating elements made from molybdenum disilicide (MoSi2)
- Low power requirements
- Heating elements controlled via thyristors, ensuring extremely precise furnace control; wear-free and silent operation
- High temperature accuracy inside the furnace chamber
- Exhaust vent in the furnace ceiling
Incl. PC: HP Compaq dx2300 Microtower Dx2300M/E2160/160hnd/1024L/4rf, Dual Core with Microsoft XP + DVD drive + 19" Philips monitor Model ID: 190B4CS/00 (Company: Bechtle, Heilbronn 26.09.2003 net €528 Inventory No. 5633) with Eurotherms iTools with Wizards pre-installed and on DVD, all necessary cables, keyboard, Logitech wireless mouse
Listing
Győr
8,518 km
Temperature test chamber -72°C to +180°C
VötschVTS 7060-5 600 Liter
Call
Year of construction: 2016, operating hours: 14,242 h, condition: excellent (used), Vötsch temperature test chamber, water-cooled
Here we offer you a Vötsch temperature test chamber.
Vötsch 7060-5 water-cooled chanber
Test chamber dimensions: Height: 950 mm, width: 800 mm, depth: 800 mm
External dimensions: Height 1995 mm, width: 1090 mm, depth: 1960 mm
Test chamber capacity: approx. 600 liters
Year of construction: 2016
Operational hours: 14 242
Entry ports:
R1: NW 125 mm
L1: NW 50 mm
Data for temperature tests:
Temperature range: -72°C to +180°C
Temperature deviation in time in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature change rate
Heating 6.0 K/min
Cooling 6.0 K/min
Heat compensation at 20°C max. 5000 W
Heat compensation at -20°C max. 5000 W
Ncodpjt Txqrsfx Ac Tju
Electrical connection:
Rated voltage: 3/NPE AC 400V ±10% 50Hz
Rated power: 13,0 kW Rated current: 23.0 A
Refrigerant: R-404A and R-23
Weight (approx.): 650 kg
The following information is for your safety as a buyer!
1. The chamber works perfectly.
2. No components have to be replaced.
3. Refrigerant is filled with legally compliant.
Condition: used (excellent)
(Changes and errors in the technical data, specifications are reserved!)
Listing
Borken
7,614 km
Temperature Test Chamber -40 to +100°C
FeutronTPK 3403/125
Call
Condition: good (used), Feutron Temperature Test Chamber: -40 to +100°C
Thanks to its robust construction, the Feutron TPK 3403/125 is a workhorse for standardized temperature testing.
The primary areas of application for this model are:
1. Electronics and Component Testing
This is the most common area of application. It focuses on how components react to extreme temperatures:
Functional Testing: Does the circuit board continue to operate flawlessly even at -40°C or +150°C?
Burn-In Testing: Artificial aging of components through continuous operation at high temperatures to induce early-stage failures.
2. Materials Testing
Investigation of physical changes in materials:
Brittleness: Do plastics or rubber seals become brittle in cold conditions?
Deformation: Do composite materials warp when exposed to heat?
Storage Testing: How stably do chemical substances or adhesives behave over extended periods at a constant temperature?
3. Quality Assurance (QA)
Ncsdpfx Acsy Nynas Tsu
Sample Testing: In-process testing conducted alongside production to ensure that manufacturing output adheres to specified temperature ranges.
Standards Compliance Testing: Conducting tests in accordance with common industry standards (e.g., DIN EN 60068) that prescribe specific temperature profiles.
4. Research & Development
Prototyping: Testing new housing designs or materials under controlled thermal conditions prior to mass production. Manufacturer: Feutron
Model: TPK 3403/125
Temperature Range: -40 to +100°C
Refrigeration System: Air-cooled condenser
Temperature Stability: approx. ±0.1 to ±0.5 K
Usable Chamber Volume: approx. 125 liters
Refrigerant: R22
Operating Pressure: 23 bar
Power Supply: 220/280V-3-50Hz
Input Fuse Rating: 25 A
Protection Class: IP 20
Weight: 480 kg
"Everything from a single source: We would be happy to offer you suitable bank financing for your project."
komplett-konzept.leasingo.de
You can find additional items—both new and used—in our shop!
International shipping costs available upon request!
Listing
Borken
7,623 km
Climatic chamber temperature and humidity
EspecPL-3KPH -40°C bis 180°C
Call
Condition: excellent (used), ESPEC Climate Test Chamber PL-3KPH
Device Data
Manufacturer: ESPEC
Model: PL-3KPH
Design: Climate Test Chamber
Cooling: Air-cooled
Description
Used climate test chamber from ESPEC.
Suitable for temperature and humidity testing.
For use in research, development, and quality assurance.
Operating Condition
Display: STOP / ready for operation.
Technical Data
Temperature range: -40°C to +180°C
Humidity range: 20% to 98% RH
Test chamber volume: approx. 400 liters
Dimensions
Internal (W x H x D): 600 x 850 x 800 mm
External (W x H x D): 1010 x 1690 x 1195 mm
Electrical Data
400 V / 3~ / 50 Hz
Refrigeration System
Refrigerant: R404A / R23
Two-stage cooling system
Air-cooled (no external water connection required)
Weight
Approx. 350 kg
Equipment
Touchscreen control panel
Programmable and constant mode operation
BTHC temperature and humidity control
Observation window
Stainless steel test chamber
Internal lighting
Cable port
Overheating protection
Hour counter
Industrial design
Scope of Delivery
ESPEC Climate Test Chamber PL-3KPH
Scope of delivery as shown
Service before delivery (optional)
Function test
Refrigerant service
Leak test
Test run with protocol
Nedoy H H Iuspfx Ac Tjcu
Condition
Used.
Condition as shown in photos.
Note
Used device, sale without warranty.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to prior sale and changes.
If you have any questions, feel free to contact us.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 4,748 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5
water-cooled, 1000 liters, year of manufacture 2021,
operating hours 4979.69 h
Ncjdpfxey El Ttj Ac Tou
For sale is a used temperature test chamber manufactured by Weiss Technik. This chamber is utilized for testing components and materials under various temperature conditions (e.g., cold, heat, aging).
Designation breakdown:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = low temperature range (-70 °C)
e = energy-optimized design
5 = temperature change rate (model series)
Equipment/features:
- Stainless steel interior
- Recirculating air fans
- Touch control (WEBSeason)
- Viewing window
- Automatic/manual temperature control
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rates:
Cooling approx. 6 K/min
Heating approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
For your safety as a buyer, please note the following information! The following work is carried out on our offered chambers beforehand:
1. Functional inspection and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in technical data; specifications may vary!)
If you have further questions, we are happy to assist you by phone.
Listing
Borken
7,623 km
Temperature test chamber 1000 liters
WeissWT-1000/70/5 -70 °C bis +180 °C
Call
Condition: excellent (used), Weiss WT-1000/70/5 Temperature Test Chamber
For sale is a pre-owned temperature test chamber manufactured by Weiss, model WT-1000/70/5.
This unit is designed for precise temperature testing in industrial and laboratory environments, and is suitable for use in research, development, and quality assurance applications.
The test chamber allows for reproducible temperature cycles across an extended temperature range and is particularly suitable for material testing, aging tests, and stress tests under defined temperature conditions.
Technical Data
Manufacturer: Weiss
Model: WT-1000/70/5
Type: Temperature Test Chamber
Temperature Range: -70 °C to +180 °C
Temperature Deviation (over time, center of usable space): ± 0.1 to ± 0.5 K
Temperature Homogeneity (spatial): ± 0.5 to ± 2 K
Heating rate: 6.1 K/min
Cooling rate: 6 K/min
Test chamber volume: approx. 1000 liters
Test chamber dimensions (approx.): 950 x 1100 x 950 mm (H x W x D)
External dimensions (approx.): 2000 x 1415 x 2105 mm (H x W x D)
Permissible total load, test chamber floor: 150 kg
Permissible load per shelf: 50 kg
Rated voltage: 3/N/PE AC 400 V ± 10% / 50 Hz
Rated current: 38 A
Rated power: 26 kW
Refrigerants: R404 / R23
Weight: approx. 955 kg
Features
- Water-cooled system
- Spacious test chamber
- High rate of temperature change
- Industrial grade construction
Condition
Used, with age- and use-related signs of wear.
Service / Inspection
For quality assurance, the following work is carried out on the offered systems:
- Function check and replacement of necessary components
- If required, refilling with legally compliant refrigerant
- Leak test with certificate
- Documented test run following successful inspection
Nsdpfey D Nyuox Ac Tocu
Scope of delivery
- Weiss WT-1000/70/5 temperature test chamber
- Accessories as shown
Notes
- Connection via 400 V three-phase power required
- Shipping by freight carrier required due to size and weight
- Sale from commercial inventory
- All information subject to change
- Prior sale reserved
- For further information, feel free to contact us.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 4,748 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021,
total operating hours: 4748.2 h
For sale is a used temperature test chamber from Weiss Technik. This chamber is used for testing components and materials under various temperature conditions (e.g. cold, heat, aging).
Model designation explanation:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = low-temperature range (-70 °C)
e = energy-optimized design
5 = temperature change rate (model series)
Equipment features:
Nsdpsy Dd Nqjfx Ac Tjcu
- Stainless steel interior
- Recirculating air fans
- Touch control (WEBSeason)
- Viewing window
- Automatic/manual temperature control
Technical specifications:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling approx. 6 K/min
Heating approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
For your peace of mind as a buyer, the following work is carried out on our chambers prior to sale:
1. Functional inspection and replacement of any necessary components
2. New filling with legally compliant refrigerant when required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in technical data and specifications reserved!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 5,128 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021
Operating hours: 5018 h
For sale is a used temperature test chamber from Weiss Technik.
This chamber is used to test components and materials under various temperature conditions (e.g., cold, heat, aging).
Meaning of the designation:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = low temperature range (-70 °C)
e = energy-optimized design
5 = temperature change rate (series)
Features:
- Stainless steel interior
- Recirculating air fans
- Touch operation (WEBSeason)
- Viewing window
- Automatic / manual temperature control
Technical specifications:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rates:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1300 kg
For your peace of mind as a buyer, please note the following:
The following procedures are carried out on all chambers prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see photos)
(Specifications and data are subject to change and errors reserved!)
If you have any further questions, we will be happy to answer them by phone.
Njdey Dclwepfx Ac Tocu
Trust Seal
Dealers certified through Used-Machines

Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 5,018 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021
Operating hours: 5018 h
For sale is a used temperature test chamber from Weiss Technik.
The test chamber is used for testing components and materials under various
temperature conditions (e.g., cold, heat, aging).
Designation meaning:
T = Temperature test chamber
1000 = approx. 1000 liters volume
70 = low-temperature range (-70 °C)
e = energy-optimized version
5 = temperature change rate (series)
Features:
- Stainless steel interior
- Recirculation fans
- Touch operation (WEBSeason)
- Viewing window
- Temperature control (automatic/manual)
Technical specifications:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (H x W x D)
Internal dimensions: approx. 950 x 1100 x 950 mm (H x W x D)
Connection: 400 V / 50 Hz / 3-phase
Rated current: approx. 34 A
Power: approx. 21 kW
Ncjdpfx Acjy Dclqs Tou
Refrigerant: R449A / R23
Weight: approx. 1300 kg
For your peace of mind as the buyer, the following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical specifications!)
We are happy to answer any further questions by phone.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 5,128 h, condition: excellent (used), Weiss Temperature Test Chamber TempEvent T/1000/70e/5, water-cooled, 1000 liters, year of manufacture 2021, operating hours: 5128 h
For sale is a used temperature test chamber from Weiss Technik. This chamber is designed for testing components and materials under various temperature conditions (e.g. cold, heat, aging).
Model designation explanation:
T = Temperature test chamber
1000 = approx. 1000 liters capacity
70 = low temperature range (-70 °C)
e = energy-optimized version
5 = temperature change rate (series)
Equipment features:
- Stainless steel interior
- Recirculating air fans
- Touch operation (WEBSeason)
- Viewing window
- Automatic/manual temperature control
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Njdpfx Acey Dck Te Tecu
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (HxWxD)
Internal dimensions: approx. 950 x 1100 x 950 mm (HxWxD)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerant: R449A / R23
Weight: approx. 1200 kg
For your security as a buyer, please note the following information:
The following steps are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful checking, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see pictures)
(Specifications and technical details subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
WeissTempEvent T/1000/70e/5 1000 Liter
Call
Year of construction: 2021, operating hours: 4,748 h, condition: excellent (used), Weiss
Temperature Test Chamber TempEvent T/1000/70e/5,
water-cooled, 1000 liters, year of manufacture 2021,
running hours: 4748 h
Offered for sale is a used temperature test chamber from Weiss Technik. The chamber is used for testing components and materials under various temperature conditions (e.g., cold, heat, aging).
Explanation of the model designation:
T = temperature test chamber
1000 = approx. 1000 liter volume
70 = low temperature range (-70 °C)
Ncjdpfx Acoy Dciij Tju
e = energy-optimized version
5 = temperature change rate (series)
Equipment features:
- Stainless steel interior
- Recirculation air fans
- Touch control (WEBSeason)
- Viewing window
- Automatic / manual temperature control
Technical data:
Model: TempEvent T/1000/70e/5
Internal volume: approx. 1000 liters
Temperature range: approx. -70 °C to +180 °C
Temperature change rate:
Cooling: approx. 6 K/min
Heating: approx. 8 K/min
External dimensions: approx. 2000 x 1415 x 2030 mm (HxWxD)
Internal dimensions: approx. 950 x 1100 x 950 mm (HxWxD)
Connection: 400 V / 50 Hz / 3~
Rated current: approx. 34 A
Power: approx. 21 kW
Refrigerants: R449A / R23
Weight: approx. 1200 kg
Important safety information for buyers:
The following processes are carried out on the chambers we offer before delivery:
1. Function check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions by phone.
Listing
Dortmund
7,674 km
High temperature debinding furnace
GEROHBO 50/13-3 2G
Call
Condition: excellent (used), High temperature debinding furnace, make GERO
type: HBO 50/13-3 2G
heating: electrical
useable space: ø400 x 400 mm
temperature: max. 1.300°C
Nodohgiz Ijpfx Ac Tscu
ventilation: exhaust fan during the cooling phase
and activated cooling fan
ultimate vacuum: 10 mbar
exhaustion time: ca. 5 min
nitrogen: inlet pressure min. 3 bar
oxygen: inlet pressure min. 3 bar