Used Temperature Shock Chamber Climate Test for sale (18,749)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Climate test chamber with solar simulation
Atlas / WeissSolarClimatic SC-340
Call
Condition: excellent (used), Atlas
Type: SC 350 MHG
Atlas Solar Climatic Test Chamber, Air-Cooled
For sale is an ATLAS SC-340 MHG SolarClimatic Test Chamber
(climatic chamber with solar simulation via MHG lamp).
The device is suitable for carrying out standardized weathering and aging tests under the combined influence of radiation, temperature, and climate.
Features & Highlights:
- Precise temperature and humidity control
- Integrated humidification system with water reservoir
- Cooling via water or air system (optional)
- Feed-throughs available for measuring leads
- Control via control panel or interfaces (RS232, etc.)
- Sturdy test chamber floor, loadable up to 60 kg (optionally reinforced to 150 kg)
General Data:
Model: SC 340 MHG
Test chamber volume: approx. 335 liters
Cabinet weight: approx. 500 kg
Irradiation unit weight: approx. 65 kg
Technical Data:
Test volume: 340 l (internal dimensions 580 × 765 × 750 mm)
Kedoxbd Raepfx Ak Ejlt
External dimensions (W×D×H): 865 × 1,595 × 2,180 mm
Light source: 1 × 1,200 W MHG lamp
Irradiance: 800–1,200 W/m²
Illuminated area: approx. 3,300 cm²
Weathering spectrum: 300–3,000 nm, compliant tests according to DIN 75220, IEC 60068-2-5, MIL-STD-810F
Temperature range with irradiation: –20 °C to +100 °C (±1 K)
Temperature range without irradiation: –30 °C to +100 °C (±0.1–0.5 K)
Heating/Cooling rates: 3.0 K/min (heating), 2.5 K/min (cooling, without irradiation)
Noise level: approx. 58 dB(A) at a distance of 1 m
Power supply: 400 V, 3/N/PE, 50 Hz
Power consumption: max. 6.2 kW, 16 A
Refrigerant: R-404A
Weight: approx. 565 kg
Information for your safety as a buyer!
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers are subjected to a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical details subject to change and errors reserved!)
Feel free to contact us by phone for any further questions.
Listing
Borken
7,623 km
Temperature test chamber -70°C to +180°C
VötschVT 7021
Call
Condition: excellent (used), Heraeus Vötsch
Type: VT 7021
Air-cooled temperature test chamber
1 port, nominal width 80 mm,
Test chamber volume: 210 liters
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (heating): 2.5 K/min
Temperature change rate (cooling): 2.5 K/min
Max. heat compensation: 800 W
Test chamber dimensions: Width 560 mm, Depth 570 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1250 mm, Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50 Hz
Rated power approx. 1.8 kW, rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
Kedpswylv Djfx Ak Eelt
For your safety as a buyer, please note the following information!
The following procedures are performed on the chambers we offer, in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors in the details!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,623 km
Temperature test chamber 1000 liters
CTS - 70°C bis +180°CTS -70/1000-10 bis ca.10 K/min
Call
Condition: good (used), Type: TS -70/1000-10
For sale is a CTS temperature test chamber
Model: TS -70/1000-10
Cooling: water-cooled refrigeration unit
Compressor has been replaced!
Features:
- Multi-touch control system
- USB and Ethernet interfaces
- Cable feedthroughs for test cables: 4 × Ø 125 mm
- Safety temperature limiter
Applications:
- Environmental and longevity tests
- Thermal cycling tests (stress screening)
- Quality assurance and research & development
- Electronics, automotive, materials testing
Test chamber volume: 1,000 liters
Test chamber dimensions:
- Height: approx. 1,000 mm
- Width: approx. 860 mm
- Depth: approx. 1,100 mm
External dimensions:
- Height: approx. 1,950 mm
- Width: approx. 1,270 mm
- Depth: approx. 1,900 mm
Temperature range: -70°C to +180°C
Temperature deviation: ± 0.3 K over time
Temperature change rate: up to approx. 10 K/min
Electrical connection: 400V 3/N 50Hz
Rated power: approx. 23.1 kW
Rated current: approx. 40 A
Refrigerant: R404A / R23
Kodpfx Akexdi Ezs Ejlt
Weight: 1,000 kg
For your peace of mind as a buyer, please note:
The following inspections and services are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. Following successful checks, chambers undergo a documented test run
Condition: used
Scope of delivery: (See pictures)
(Specifications and technical data subject to change and errors excepted!)
We are happy to answer further questions by phone.

Get information now
+49 201 857 86 122
+49 201 857 86 122
List now
*per listing / month
Listing
Borken
7,623 km
Climatic test chamber with humidity, 600 liters
CTSC-40/600 -40 bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber Type: C -40/600, Air-Cooled
(converted to R-452a refrigerant)
Test chamber volume: 600 liters
Temperature tests:
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K over time (at stabilized condition)
- Average temperature rate of change (without test load and radiant heat):
- Heating: 2.5 K/min
- Cooling: 3.0 K/min
- Maximum radiant heat input: 2500 W at +20°C
Climatic tests:
- Climate range / Technical data:
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
- Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
- Humidity consistency II: ±1% r.h. to ±3% r.h.
- Temperature consistency: ±0.1 K to ±0.3 K
Chamber internal dimensions (approx.): Height: 850 mm, Width: 850 mm, Depth: 830 mm
External dimensions (approx.): Height: 1900 mm, Width: 1115 mm, Depth: 1850 mm
Refrigerant: R-452A
Power connection: 400V 3/N 50Hz
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for your purchase!
The following checks and procedures are performed on all our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see image)
Kodpfjw U Awmox Ak Eelt
(Subject to changes and errors in the technical data and specifications!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
7,623 km
Temperature test chamber
CTSTS -70/600-13
Call
Condition: used, CTS
Type: TS -70/600-13
Temperature test chamber, water-cooled
Type series: TS -70/600-13
Control system:
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
- Numerical input of setpoint values
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Test chamber volume: 600 liters
Test chamber dimensions: Height approx. 730 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions: Height approx. 2250 mm, width approx. 1300 mm, depth approx. 2475 mm
Temperature range: -70 to +180°C
Heating speed: 13 K/min at -40°C to +120°C
Cooling speed: 13 K/min at 120°C to -40°C
Temperature deviation: ± 0.1K temporal, ± 0.5 K spatial
Electrical connection 400/3P/N/PE
Nominal power: approx. 27.8 kW
Nominal current: approx. 44.1 A
Compressor: 4TC-8.2Y/4PC-10.2Y
Refrigerant: R-404 A / R-23
Kljdpfx Aevcyawsk Est
Weight: 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature shock test system
RS-SimulatorenST2K320/45 K
Call
Condition: excellent (used), RS. simulators
Type: ST2K320/45 K
Water-cooled shock test system
Temperatures in the upper test chamber
Temperature range: + 40 °C to + 180 °C
Kledpfx Astrf Ulsk Est
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Temperatures in the lower test chamber
Temperature range: - 40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Humidity in the upper test room
Climatic temperature range: + 40 °C to +90 °C
Humidity range: 20 % to 98 % (± 2 to 5 %) relative humidity
Humidity: 25% to 75% relative humidity
Working climate range:
Temperature: + 12 °C to + 30 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 900 mm Height 2000 mm Depth 2300 mm
Test room dimensions: Width 470 mm Depth 700 mm Height 440 mm
Electrical power supply:
Total power: 13 KVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, condition: excellent (used), Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VLM 3068/S air-cooled
(building material test chambers loaded from above)
Control panel
The control panel is mounted on a console on the temperature test chamber. By
control and operating commands can be triggered by simply touching the function symbols.
can be triggered. The operating instructions for the control panel are enclosed
Main switch
The main switch is located at the front of the temperature test chamber.
Air treatment room
The air treatment room is located in the test room
and contains the components required for temperature control.
In the air treatment room, the air is tempered (cooling/heating) and circulated by the test room fan.
circulated by the test room fan. The air is sucked in at the center of the side wall and
enters the test chamber again via the air baffles on the long sides.
Feed-throughs
The temperature test chamber can optionally be equipped with feed-throughs. Through these
can be used to route cables and test equipment into the test chamber.
Entry port front 2 x 82 mm ∅ rear 1 x 85 mm ∅
Internal dimensions Width 2000 mm Depth 570 mm Height 600 mm
External dimensions Width 3000 mm Depth 870 mm Height 1060 mm
Technical data:
Data for mechanical load:
Max. load with test material
Test area floor
(evenly distributed over the surface) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Kljdpfx Aksrbiyfo Est
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Nominal voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Customer fuse 16A slow-blow
Temperature test chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber ex protected
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Kodpfxsihb Amj Ak Eelt
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Listing
Borken
7,623 km
Climate test chamber 600 liters
WeissWK3-600/70 -70°C bis +180°C
Call
Condition: good (used), Weiss
Type: WK3-600/70
Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to +180°C
Temperature change rate:
Heating: 4.0 K/min
Cooling: 2.5 K/min
Temperature deviation:
Over time: ±0.1 to ±0.5 K
Spatially: ±0.5 to ±1.5 K
Heat compensation max.: 2,500 W
Specifications for Climate Testing:
Temperature range: +10 to +95 °C
Dew point temperature range: -3 to +94°C
Humidity range: 10 to 98 % rH
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1 K
Humidity deviation over time: ±1 to ±3 % rH
Temperature uniformity (spatial): ±0.5 to ±1.0 K
Heat compensation max.: 500 W
Test chamber volume: 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1,998 mm, Width 1,000 mm, Depth 1,745 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19.0 A
Refrigerant: R404A & R23
Kodpfx Aew Inmmek Ejlt
Weight: 680 kg
Important information for you as the buyer:
The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications subject to change. Errors and omissions excepted!)
If you have any further questions, we are happy to answer them by phone.
Listing
Borken
7,623 km
Climate test chamber with humidity
Weiss -72°C bis +180°CWK3-340/70
Call
Condition: excellent (used), Weiss
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
Ksdpov Sr Hzefx Ak Ejlt
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climatic test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), Here we offer a Weiss climatic test chamber.
Water-cooled
Test chamber lighting Halogen bulb 24V, 50W
Data for temperature tests:
Temperature range: -40°C to +180°C
Temporal temperature deviation in the center of the chamber: ± 0.3 to ± 0.8 K
Spatial temperature deviation: ± 0.5 to ± 2 K
Temperature change rate
Heating: 10 K/min
Cooling: 12.5 K/min
Heat compensation at +20°C 8000 W
Heat compensation at -20°C 3000 W
Data for climate tests
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % r.h.
Temperature deviation in time in the center of the usable space: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH
Test chamber dimensions: Height 950 mm, width 760 mm, depth 650 mm,
External dimensions: Height 2025 mm, width 1090 mm, depth 2480 mm,
Nominal voltage: 3/N/PE AC 400 V ± 10% 50 Hz
Rated current: 24 A Rated power: 16.0 KW
Refrigerant: R452A
Weight: approx. 900 kg
Type: WK-480/40/10
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Kodpfx Aksq Dpzye Eolt
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Climate test chamber 990 liters
Weiss – 40…+ 180°CWK11-1000/40 mit Zander K-MT 2
Call
Condition: excellent (used), Weiss
Model: WK11-1000/40
For sale is a professional Weiss Umwelttechnik WT-WK 1000/40 climate test chamber with fully automatic cold-regenerating adsorption dryer.
The installed fixtures in the test chamber can be removed if required. Currently, due to these fixtures, the control cabinet is limited to a temperature range of −40°C to +60°C. Once the fixtures are removed, the manufacturer can expand the temperature range back to the standard values of −40°C to +180°C, as the fixtures are not suitable for these higher temperatures.
This equipment is ideal for precise temperature and humidity testing on components, assemblies, and devices. It is perfectly suited for applications in industry, development, quality assurance, and research.
Weiss Climate Test Chamber – Water Cooled
Data for Temperature Tests:
- Temperature range: −40°C to +60°C
- Temporal temperature fluctuation (at center of usable space): ± 0.1 to ± 0.5 K
- Spatial temperature deviation: ± 0.5 to ± 2.0 K
- Temperature change rate:
- Heating: 4 K/min
- Cooling: 3 K/min
Data for Climate Tests:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98 % r. H.
- Temporal temperature fluctuation (at center): ± 0.1 to ± 0.3 K
- Spatial temperature deviation: ± 0.5 to ± 1 K
- Temporal humidity fluctuation (at center): ± 1 to ± 3 % r. H.
- Thermal compensation:
- In the range of +25°C to +95°C
- At a relative humidity of up to 90%, 500 W
Humidification System Data:
Klsdsx Hxkzopfx Ak Est
- Reservoir volume: 20 l
- Water quality: demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 μS/cm³
- Water consumption at constant +40°C, 92% r. H.: 21/24 h
- Temperature gradient:
- (according to IEC 60068-3-5): 1 to 2 K
Test Chamber Dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External Dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Test Chamber Volume: approx. 990 liters
Nominal Voltage: 3/N / PE AC 400 V +10% 50 Hz
Nominal Power: 11.5 kW, Nominal Current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
Important information for your safety as a buyer!
The following steps are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Technical data subject to modifications and errors!)
Further questions can be answered via telephone.
Listing
Borken
7,623 km
Shock test chamber –75°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Water-cooled
Two-chamber configuration
Hot chamber:
Temperature range of hot chamber: +50°C to +220°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature range of cold chamber: -74.5°C to +70°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Kodpfx Ajx Hhfhsk Ejlt
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Port diameter: 67 mm
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerants: R-452A / R-23
Weight: 1000 kg
Important safety information for buyers:
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
We are happy to answer further questions by phone.
Listing
Borken
7,623 km
Climate test chamber 190 liters
VötschVC³ 7018 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 7018
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Humidity Range: 10% to 98% RH F.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Kljdpfx Asx Hg Uujk Ejt
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature test chamber 480 liters
VötschVTS 7048-10 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VTS 7048-1
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Performance Data:
With a temperature change rate of 10 K/min
Test chamber internal dimensions: height 950 mm, width 800 mm, depth 650 mm
External dimensions: height 2025 mm, width 1000 mm, depth 2480 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.3 to ±0.8
Spatial temperature uniformity: ±0.5 to ±2
Temperature change rate (cooling): 10 K/min
Ksdpfx Aoxzgn Iek Eslt
Temperature change rate (heating): 10 K/min
Heat compensation at -20°C: 8,000 W
Heat compensation at +20°C: 8,000 W
Test volume: 480 liters
Left: 1x side port, ∅ 125 mm
Left: 1x side port, ∅ 50 mm
Right: 1x side port, ∅ 125 mm
Chamber is water-cooled
Test chamber illumination:
Halogen bulb: 24 V, 50 W
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 17 kW
Rated current: 30 A
Refrigerant: R-404A / R-23
Weight: approx. 1,250 kg
Important information for your safety as a buyer!
The following steps are carried out in advance on our offered chambers:
1. Function check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Specifications are subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Schweinfurt
7,931 km
Temperature test cabinet - vibration chamber
RS-SimulatorenVTS 1200/75
Call
Condition: used, Description: Temperature test chamber
Manufacturer: RS-Simulators / VTS 1200/75/S
Temperature range: -75 to +180°C
External dimensions: 2.30 x 2.30 x 2.80 m (L/W/H)
Test chamber dimensions: 1.10 x 1.00 x 1.00 m (L/W/H)
Unit: 2.30 x 1.30 x 2.00 (L/W/H)
Average heating rate: approx. 5 K/min (from -40 to +150°C)
Average cooling rate: approx. 5 K/min (from +150 to -40°C)
Current: 38 A
Connection voltage: 3 x 400V/NPE 50 Hz
Weight: approx. 2700kg
Item condition:
used item
Contact us if you have any questions
Kjdpfxswp Ip Ej Ak Eslt
Shipping:
the stated shipping costs apply to deliveries within Germany
Worldwide shipping (shipping costs outside Germany on request)
Worldwide shipping (please kindly request shipping costs)
The given shipping costs apply to shipping within Germany
Sale only to commercial customers without warranty or guarantee.
Deviations from technical data as well as errors in the description of the items may occur and are reserved.
Listing
Amstetten
8,329 km
Weiss climate test chamber SB11/300/40 -40..
WEISSSB11/300/40
Call
Year of construction: 1995, condition: excellent (used), functionality: fully functional, machine/vehicle number: SB11/300/40, For sale is a Weiss climate test chamber.
Designation: SB11/300/40
Cooling-heating operation: -40...+180 °C
Climate operation: +10...+95 °C
Humidity range: 10...98 % RH
Temperature stability
The temporal temperature stability in climate mode is ±0.1...±0.5 K
The temporal temperature stability in cooling-heating mode (without climate) is ±0.2...±0.5 K
Humidity stability
The temporal humidity stability across the entire operating range is ±2...±3 %RH
Condenser: air-cooled
Rate of temperature change:
Cooling: approx. 3.1 K/min
Heating: approx. 3 K/min
Test chamber volume: approx. 301 L
Internal dimensions: Height 680 mm, Width 540 mm, Depth 820 mm
External dimensions: Height 1700 mm, Width 800 mm, Depth 1780 mm
Weight: approx. 420 kg / Power supply: 4.8 kVA
Electrical connection: CEE plug 16 A
Ksdpfsw Dygfex Ak Ejlt
Connection voltage:
400V/3Ph+N+PE/50 Hz (+6%/-10%)
Refrigerant: R404A!
Version: mobile
Type: SB11/300/40
Listing
Borken
7,623 km
Shaker SALL50F + climate chamber
Unholtz-DickieTA117SA-560 Vibrationsprüfanlage
Call
Condition: good (used), UNHOLTZ-DICKIE / HS-Simulators Vibration Testing System
Type: TA117SA-560 + HS 520 K 60 V
Manufacturer: UNHOLTZ-DICKIE Corporation / HS-Simulators Horstmann GmbH
For sale is a complete electrodynamic vibration testing system consisting of an UNHOLTZ-DICKIE shaker system, SALL50F power amplifier, VWIN II control system, and an HS-Simulators climate chamber. Ideal for combined vibration and climate testing in industrial, automotive, aerospace, electronics testing, as well as research and development applications.
The hall crane / other hall equipment visible in the pictures is not included in the scope of supply.
Shaker / Vibrator
Manufacturer: UNHOLTZ-DICKIE Corporation
Type: 560
System: TA117SA-560
Serial Number: 259
Air-cooled electrodynamic shaker
Sine force: 6000 lbf peak / 26.7 kN peak
Random force: 5200 lbf RMS / 23.1 kN RMS
Max. acceleration of free table: 100 g / 981 m/s²
Shaker stroke: 1 inch / 25.4 mm
Axial resonance frequency: approx. 2200 Hz / approx. 2.2 kHz
Armature effective weight:
45 lb / approx. 20.4 kg
Driver Coil:
200 A Sine
140 A Random
Air-cooled and vibration-isolated system.
Power Amplifier
Manufacturer: UNHOLTZ-DICKIE Corporation
Type: SALL50F Power Amplifier
Serial Number: 4414
Power Module: PML-50-S
Master Controller: MCLL50
Supply voltage:
400 V / 3 Phase / 50 Hz
Power consumption:
41 kVA / 60 A
Blower: 15 kVA / 22 A
Maximum Driver Currents:
440 A RMS OUT SINE
300 A RMS OUT RANDOM
Forced air cooling.
Control System
UNHOLTZ-DICKIE VWIN II DSP Vibration Control System
including industrial PC / monitor as shown in the pictures
Control Console:
MA117SA-560
Serial Number: 1838
Charge Amplifier:
Type 122P
Serial Number: 8963
Supported test types:
Random Vibration
Sine Vibration
Resonance Dwell
Classical Shock Pulse
SRS Shock & Analysis
Sine-on-Random
Random-on-Random
Gunfire
Interfaces:
TCP/IP
RS232
Ethernet
USB
HS-Simulators Climate Chamber
Manufacturer: HS-Simulators Horstmann GmbH
Type: HS 520 K 60 V
Temperature range: -60 °C to +180 °C
Electrical data:
380 V
17 A
10 kW
Refrigerant:
R13
R502
Features:
Combined climate and vibration testing
Complete electrodynamic testing system
DSP-based real-time control
Forced air cooling system
Completely wired testing system
Original documentation available:
Operating Manual
Maintenance Manual
System Specifications
System Diagrams
Performance Curves
Kedsy S S Eispfx Ak Eelt
Dimensions / Weight
Amplifier:
approx. 1000 x 537 x 825 mm
Climate chamber:
approx. 1200 x 1800 x 2000 mm
Total weight estimated:
approx. 2500 – 4000 kg
Transportation only by a suitable heavy-duty transport company.
Technical data partially estimated.
Specifications may vary.
Condition
Used system from industrial application.
Optical condition see pictures.
Functionality not fully tested.
Inspection possible and desired upon agreement.
Scope of delivery
UNHOLTZ-DICKIE shaker model 560
SALL50F power amplifier
Control console / control system
VWIN II controller system
Charge amplifier
HS-Simulators climate chamber HS 520 K 60 V
Industrial PC / monitor as shown in the pictures
Documentation and accessories as shown in the pictures
Loading possible upon agreement.
Commercial sale without warranty.
Errors and prior sales excepted.
Listing
Żychlin
8,290 km
Binder MKF 720 E5 climate chamber
BinderMKF 720
Call
Year of construction: 2025, condition: like new (used), Binder MKF 720 E5 Climate Chamber, year 2025.
Brand new, unused chamber with 3-year warranty on spare parts.
The Binder MKF 720 E5 is a professional climate/environmental chamber designed for stability studies, temperature, and climate testing in compliance with DIN and IEC standards. The E5 series is part of Binder’s latest generation, featuring a touchscreen interface and advanced program control.
Key features:
* Temperature range: -40°C to +180°C
* Humidity range: 10–98% RH
* Chamber volume: approx. 734 liters
* APT.line™ preheating chamber technology
* Ultra-fast temperature changes
* Humidity control via capacitive sensor + steam humidification
* Binder E5 touchscreen controller with segment and time programming
* Integrated data logger + data export via USB
* Ethernet interface
Klsdey Sg Nvopfx Ak Eet
* Heated inspection window with LED lighting
* Automatic water supply and drainage management
* Stainless steel interior chamber
* Compressor cooling
* Refrigerant: R-452A
Listing
Żychlin
8,290 km
Binder KBF 720 E7 climate chamber
BinderKBF 720 E7
Call
Year of construction: 2026, condition: like new (used), Binder KBF 720 E7 from 2026.
Device is like new, 2-year warranty on spare parts.
PRODUCT DESCRIPTION
A proven specialist for reliable ICH stability testing in the pharmaceutical industry: the KBF handles all long-term tests, accelerated tests, and extreme condition tests. It meets all important ICH requirements, from precision to programming and documentation. Features flexible water supply options for all installation sites. Additionally, the new KBF consumes up to 40% less energy than its predecessor. With optional lighting modules, the KBF becomes an ICH photostability testing chamber or a plant growth chamber.
KEY FEATURES
Temperature range:
0°C to 70°C
Humidity range from 10% to 80% RH
Proven APT.line™ preheating chamber technology
Energy savings of up to 40% compared to previous model
Energy-efficient cooling thanks to modern inverter refrigeration unit
Cooling using environmentally friendly refrigerant R-600a
Heated door to prevent condensate formation
Adjustable fan speed
Humidity control with capacitive sensor and fast-reacting steam humidification
Klodoy R Uaaepfx Ak Est
Robust housing construction with HIT sandwich technology
Inner chamber made of stainless steel
Inner doors made of metal oxide-coated safety glass
Two stainless steel wire shelves
80 mm x 45 mm access port with silicone plug
Freestanding unit with durable double casters and front brakes
Intuitive controller with touchscreen and both segment programming and real-time programming
Ergonomically adjustable control terminal
Signal triangle with illuminated status indicator
Internal data logger, measurement values in open format readable via USB
Independent temperature safety device class 3.3 (DIN 12880) with visual and acoustic alarm
Device self-test for comprehensive status analysis
Data exchange interfaces:
Ethernet, USB
Optional lighting modules for ICH photostability testing
Optional LED lighting modules for plant cultivation
Listing
Borken
7,623 km
Alternating climate chamber
BinderMK 115 E3.1 -40°C bis 180°C
Call
Condition: excellent (used), Binder Temperature Cycling Chamber MK 115 E3.1
Device Data
Manufacturer: Binder
Model: MK 115 E3.1
Article number: 9020-0175
Design: Temperature Cycling Chamber
Refrigerant: R404A (1.20 kg)
Description
Used temperature cycling chamber from Binder.
Suitable for dynamic temperature tests and rapid temperature changes.
Ideal for use in material testing, research, and quality assurance.
Technology
APT.line™ preheating chamber technology
Natural simulation of temperature gradients
High precision and reproducibility
Features
MCS controller with program memory
Adjustable ramp functions
Class 2 temperature limiter (DIN 12880)
Heated viewing window with interior lighting
Ethernet interface
50 mm pass-through (left)
Stainless steel interior with shelf
4 castors (2 lockable)
Technical Data
Temperature range: -40 °C to +180 °C
Fast temperature cycling (climate change operation)
Chamber volume: 115 liters
Dimensions
Ksdsy H Hvlepfx Ak Eslt
External (W x H x D): approx. 980 x 1725 x 865 mm
Internal (W x H x D): approx. 600 x 480 x 400 mm
Electrical Data
400 V / 50 Hz
Power: 3.5 kW
Current: 11.0 A
Pressure Data
Max. operating pressure: 29 bar
Weight
Approx. 260 kg
Condition
Used. For visual and technical condition, refer to the pictures.
Scope of Delivery
Binder MK 115 temperature cycling chamber
Shelf / chamber fittings
Note
Used equipment, sold without warranty.
Inspection by appointment possible.
Loading and transport can be organized upon request.
Subject to prior sale and technical changes.
If you have any questions, please do not hesitate to contact us.
Trust Seal
Dealers certified through Used-Machines

Listing
Żychlin
8,290 km
Climate chamber Memmert ICH 750 L eco
MemmertICH 750 L eco
Call
Year of construction: 2019, condition: excellent (used), Memmert ICH 750 L eco – ex demo (2019) – L version with lighting
We offer a Memmert ICH 750 L eco climate chamber, L version (with lighting), from 2019. The unit comes directly from the manufacturer’s demonstration display, has been used very minimally, and is in excellent technical and visual condition.
Key information:
* Model: ICH 750 L eco (L version – with lighting)
* Year: 2019 (ex demo)
* Capacity: approx. 750 liters
* Temperature range:
* without humidity: from -10°C to +60°C
* with humidity: from 0°C to +60°C
* Humidity range: 10–80% RH
* Energy-saving ECO cooling system
Kljdpfx Aeymy Utek Ejt
* Digital controller with intuitive operation
* Stainless steel chamber
L version – lighting:
* Integrated lighting system (light + UV)
* Ideal for photostability testing (e.g., in accordance with ICH Q1B)
* Uniform sample illumination
* Possibility to operate in day/night cycles
Equipment and benefits:
* Precise temperature and humidity control
* Excellent uniformity of conditions inside the chamber
* Quiet and stable operation
* Reliability and high-quality Memmert construction
Condition:
Ex demo unit – minimal signs of use, fully functional, tested before sale.
Additional information:
Photos, videos of the device in operation, or an online presentation can be provided upon request.
9 months warranty on spare parts for the device.
Listing
Żychlin
8,290 km
Binder MKF 720 climatic chamber
BinderMKF 720
Call
Condition: excellent (used), operating hours: 100 h, PERFECT CONDITION, purchased in December 2016
Used for about 100h
New price is 46808 EURO
The MKF series environmental simulation chamber from BINDER is ideal for all cold and heat tests, carried out on the basis of recognized temperature and climate test standards in accordance with DIN and IEC. High operating comfort and extensive standard equipment have obvious advantages in everyday use.
Key features
Temperature range:
-40 °C to 180 °C
Humidity range:
from 10 to 98% relative humidity
Integrated 20 L water tank
4 potential-free relay contacts
e™ preheating chamber technology
Programmable condensation protection for samples
Heated viewing window with internal LED lighting
Humidity control with capacitive humidity sensor and steam humidification
BINDER Multi Management Software APT-COM™ 4 Basic Edition
Diagnostics system with optical and acoustic alarm
Kjdpfxevldnqe Ak Eelt
Intuitive touchscreen controller with time interval programming and real-time programming
Internal data logger, measured values in open format can be read via USB
2 access ports with 80 mm silicone plug, left and right
Independent, adjustable temperature protection class 2 (DIN 12880) with optical alarm
4 castors, two with brakes
230 V socket on the side panel on the right
Ramp function can be set
Integrated line recorder
Time clock actual
Door heating
Alarm message in the event of lack of water in the fresh water tank
1 stainless steel wire shelf
Protection against leaking hoses, covering the water supply and discharge pipes up to a height of 1 m
Stainless steel interior
Halogen-free refrigerant R-404A
Cooling provided by a compressor unit
Listing
Borken
7,623 km
Universal test chamber +20 °C to +300 °C
MemmertUF 450plus
Call
Condition: excellent (used), Type: UF 450plus
Air circulation: forced convection
Temperature
Temperature range: +20 °C to +300 °C
Working range: at least +10 °C above ambient temperature
Setting accuracy:
up to 99.9 °C: 0.1 °C
from 100 °C: 0.5 °C
Temperature sensors: 2× Pt100 (DIN Class A, 4-wire)
Interior and Capacity
Volume: 449 liters
Internal dimensions (W × H × D): 1040 × 720 × 600 mm
Maximum number of shelves: 8
Load per shelf: 30 kg
Maximum total load: 300 kg
Interior: Stainless steel, all-around heating
External dimensions and Weight
External dimensions (W × H × D): approx. 1224 × 1247 × 784 mm
Ksdpfx Akoyzzm Io Eolt
Net weight: approx. 160 kg
Gross weight: approx. 185 kg
Electrical Data
Voltage: 400 V, 3-phase
Power: approx. 5800 W
Control and Regulation
Controller: ControlCOCKPIT TwinDISPLAY
Regulator: digital PID microprocessor
Timer: 1 minute to 99 days
Functions: SetpointWAIT, HeatBALANCE, calibration at 3 temperature points
Adjustable parameters: temperature, fan speed, exhaust flap, time programs
Ventilation
Recirculating air: adjustable in 10% increments
Fresh air: electronically adjustable
Exhaust air: with throttle valve
Communication
Interfaces: Ethernet, USB
Software: AtmoCONTROL
Safety
Temperature limiter (TB), protection class 1
Temperature monitor/limiter (TWW/TWB) selectable
ASF system for over- and under-temperature monitoring
Equipment
Stainless steel door with 2-point locking
Stainless steel housing
Low-noise air turbine
Rear side with 2 feed-throughs approx. 12 cm diameter each
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in the technical data, information is non-binding!)
If you have any further questions, we are happy to assist you by phone.
For detailed technical data and processing instructions, we strongly recommend consulting the original datasheets or obtaining information directly from the manufacturer.
Listing
Dortmund
7,674 km
High temperature chamber furnace
NaberthermLH
Call
Condition: like new (used), temp. max.: 1300°C
internal dimensions (w x d x h): 750 x 750 x 500 mm
external dimensions (w x d x h): 1250 x 1750 x 2100 mm
loading weight : max. 150 kg
power: 44 kW
heating: 5-sides heated
control zones: 1
process control controller: yes
weight: 700 kg
voltage: 400 V 3/N
current consumption: 63 A
PLC: Siemens S7
control cabinet: brand new
- With an air heater under the furnace, pre-heated air with a temperature
of up to 400°C can be flushed into the furnace chamber during the debinding
phase.
- Controllable cooling housing with autom. valve
- Automatic exhaust damper
- Automatic exhaust flap
- Monitoring of fresh and exhaust gas volume flow, as well as furnace chamber
Kljdpfx Aksyxnk Uo Est
pressure by differential pressure monitor.
We make it easier for you to find: "temperature shock chamber climate test"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time

Get information now
+49 201 857 86 122
+49 201 857 86 122
List now
*per listing / month