Used Weiss Temperature Test Chamber 1000 Liters for sale (28,467)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Temperature chamber -70 to +180°C
EspecEGN28-6CWL
Call
Condition: excellent (used), Espec
Type: EGN28-6CWL
Espec, water-cooled
Temperature test chamber, N series
Power supply:
AC 400 V, 3-phase, 50/60 Hz, 38 A
Temperature range: -70 to +180 °C
Temperature change rate:
Heating: 10 °K/min
Cooling: 5.5 °K/min
Dodjzg Tynopfx Agmsck
Internal dimensions (W x H x D) in mm: 1000 x 1000 x 800
External dimensions (W x H x D) in mm: 1205 x 1920 x 2159
Usable volume: 800 liters
Refrigerant: R-404A
Refrigerant: R-508A
Weight: approx. 695 kg
For your safety as a buyer, please note the following:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
7,623 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Dsdpfszg Tx Rox Agmsck
Type: VCS 7034-5
Water-cooled climate test chamber
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Time-related temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Time-related temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-related humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R-404A / R-23
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions by telephone.
Listing
Borken
7,623 km
Corrosion test chamber for salt spray mist
VLMCC 1000-FL HL V.745.672.120
Call
Condition: good (used), VLM
Type: V.745.672.120 Model CC 1000-FL HL
Corrosion test chamber for salt spray tests
Specifications:
Test chamber volume: approx. 1000 L
Test chamber dimensions (W x D x H1/H2): 1400x800x800/1020 mm
Door opening dimensions (W x H): 1300x680 mm
Housing external dimensions (W x D x H): 2162 x 995 x 2080 mm
Operating temperature range: 5°C > ambient temperature to +80°C
Heavy-duty design for a load capacity of up to 350 kg
Dedpfx Agszg Tl Remeck
Process control: Beckhoff PLC, color touch screen display, 50 memory locations for test procedures, 50 memory locations for test segments, ramps:
Humidity and temperature control over the entire working area,
Ethernet connection
Electrical connection: 400 V, 50 Hz, 5700 W
Tap water: min. 2.5 bar, tap connection 3/4" external thread for connecting an ion exchange cartridge
Compressed air: 7-8 bar
Wastewater: siphon / 30 mm ID hose nozzle
Exhaust: pipe end AD 75 mm
Operating modes:
Salt spray
Condensation water (CWC)
Ventilation with ambient air
Warm air
Controlled humidity
Listing
Eindhoven
7,564 km
Climate test chamber
Vötsch/WeissGTTS 220
Call
Condition: used, Year of construction: 1980, functionality: unexamined, machine/vehicle number: GTTS 220, total height: 144 mm, total length: 135 mm, total width: 96 mm, Equipment: documentation/manual, Used Votsch/Weiss GTTS 220 Climate Chamber
Manufacturer: Votsch/Weiss
Model: GTTS 220 | 20
External dimensions: 135cm x 96cm x 144cm (length x width x height)
Max internal dimensions: 65cm x 92cm x 54/40cm (width x depth x height)
Voltage: 220/380 V
Dcodpfx Agox H N Drjmek
Refrigerant type: R12
Includes manual (installation and operation handbook)
Listing
Borken
7,623 km
Climatic chamber temperature and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical Data:
Air-cooled
Temperature and humidity range: Ambient temperature +10°C to +100°C / 40 to 98% relative humidity
Temperature fluctuation: ±0.3 K
Humidity fluctuation: ±2.5%
Internal volume: 398 liters
Dimensions:
Internal dimensions: Width 600 mm x Height 830 mm x Depth 800 mm
External dimensions: Width 1010 mm x Height 1690 mm x Depth 1273 mm
Dedpfx Aozgtahsgmsck
Mains voltage: 400 VAC 3-phase 50 Hz
Maximum current: 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climate test chamber
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Climatic chamber with humidity, 34 liters
WeissWKL 34/60 -60°C bis 150°C
Call
Condition: excellent (used), Weiss
Type: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
-60°C to 150°C
Volume: 34 liters
Installed in basic configuration:
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Performance data for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation spatially (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Performance data for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 % RH
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation spatially ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 % RH
Operating data:
Test chamber lighting Halogen bulb 12V, 20W
Rated voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
Fuse on customer side 16A slow-blow
Heat dissipation of air-cooled test chambers
Max. heat dissipation to the environment 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Dsdjzgr U Rspfx Agmeck
Scope of delivery: (See image)
(Changes and errors in technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Thermal shock test chamber
RS-SimulatorenST2K320/45 K
Call
Condition: excellent (used), RS Simulators
Type: ST2K320/45 K
Shock test system, water-cooled
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity levels in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20% to 98% (± 2 to 5%) relative humidity
Humidity: 25% to 75% relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Djdpfx Aozgbutjgmjck
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Dust test chamber dust chamber
Testzentrum Baden Primus EngineeringDST350
Call
Condition: excellent (used), Primus Engineering
Dcjdpfx Agszgbtijmjk
Type: DST 350
This testing equipment was designed for performing IP protection class tests for "dust" according to, for example, DIN 40050 Part 9 and DIN EN 60529.
The testing equipment is intended for testing technical components under the influence of dust and negative pressure within the limits specified in the technical data.
Operation / HMI
Control panel with screen and buttons
Manual controls
Predefined test sequences
Integrated vacuum circuit with flow measurement
Technical data:
Total electrical power: Max. 5 kW
Connection voltage: 400V/50Hz 3-N/PE (16A CEE socket)
Dimensions: Width approx. 920 mm, Depth approx. 710 mm, Height approx. 1,770 mm
Dimensions of test chamber: Width approx. 700 mm, Depth approx. 650 mm, Height approx. 770 mm
Volume approx. 350 l
Weight: approx. 200 kg
Vacuum: 0 to -100 mbar
Suction air flow: 0 to approx. 5 l/min
Operating climate range: Temperature: +12 °C to +30 °C
Humidity: 25 % rel. to 75 % rel., non-condensing
Protection class tests according to DIN 40050 Part 9 and DIN EN 60529 (VDE 0470 Part 1)
Dust test:
Dust-protected IP5X and IP5KX
Dust-tight IP6X and IP6KX
with and without vacuum
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Temperature cabinet 335 liters
WeissWT3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here, we offer a Weiss temperature chamber.
Weiss temperature test chamber with S!MCON / 32 control, water-cooled.
(Refrigerant converted to R-452A)
Control panel: "Touchpanel"
On the "Touchpanel" control panel, all control and operating commands can be initiated by simply touching the function symbols.
Adjustable feet
To compensate for unevenness in the floor and to ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be placed in the test chamber.
Feedthrough installed as standard:
R1: 125 mm
L1: 50 mm
Dcsdpfx Agozgbkhomok
Test chamber volume: approx. 335 liters
Test chamber dimensions: height 750 mm, width 580 mm, depth 765 mm
External dimensions: height 1775 mm, width 870 mm, depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 3.2 K/min
Cooling: 4.0 K/min
Maximum heat compensation: 2300 W
Data for operation:
Test chamber lighting: 2 x 24V, 50W halogen lamps
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 14 A, rated power 4.1 kW
Fuse: 16 A slow-blow (provided on-site)
Sound pressure level: approx.
measured at a distance of 1m from the front, 1m height: 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
Type: WT3-340/40
For your safety as a buyer, here is the following information:
The following steps are performed on our offered chambers in advance:
1. Function check and replacement of any necessary components.
2. If necessary, refilling with legally compliant refrigerant.
3. Leak test with certificate.
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Climate test chamber -40 to +180°C
WeissWK-480/40/10 480 Liter m. Feuchte
Call
Condition: excellent (used), We are offering a Weiss climate testing chamber.
Water-cooled.
Test chamber lighting: halogen bulb 24V, 50W.
Data for temperature tests:
Temperature range: -40°C to +180°C.
Temperature deviation over time in the center of the usable space: ± 0.3 to ± 0.8 K.
Temperature deviation spatially: ± 0.5 to ± 2 K.
Temperature change rate:
Heating: 10 K/min.
Cooling: 12.5 K/min.
Heat compensation at +20°C: 8000 W.
Heat compensation at -20°C: 3000 W.
Data for climate tests:
Temperature range: +10°C to +95°C.
Humidity range: 10 to 98 % RH.
Temperature deviation over time in the center of the usable space: ± 0.2 to ± 0.5 K.
Temperature deviation spatially: ± 0.5 to ± 1 K.
Humidity fluctuation over time in the center of the usable space: ± 1 to ± 3 % RH.
Test chamber dimensions: height 950 mm, width 760 mm, depth 650 mm.
External dimensions: height 2025 mm, width 1090 mm, depth 2480 mm.
Rated voltage: 3/N/PE AC 400 V ± 10% 50 Hz.
Rated current: 24 A. Rated power: 16.0 kW.
Refrigerant: R452A.
Weight: approx. 900 kg.
Type: WK-480/40/10.
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components.
2. If necessary, new filling with legally compliant refrigerant.
3. Leak test with certificate.
4. After successful inspection, the chambers undergo a documented test run.
Condition: used.
Scope of delivery: (See image).
(Changes and errors in the technical data are subject to change!)
Dcedpfszgaipex Agmek
We will gladly answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Ultra-low temperature thermostat 7.5 ... 12 liters
JulaboFP51-SL (v.2)
Call
Condition: excellent (used), Julabo
Type: FP51-SL (v.2)
Cryostat for low temperatures below -50 °C with a bath opening for internal and external temperature control.
Cryostat circulators from the HighTech series, with HL or SL thermostats, are equipped with powerful pressure and suction pumps.
The devices offer the full range of functions of the professional HighTech thermostat series.
Technical data for FP51-SL
Dimensions and volume
Dimensions (W × D × H) 46 x 55 x 89 cm
Filling volume 7.5 ... 12 l
Weight 90 kg
Pump connection thread M16x1 external thread
Temperature values:
Working temperature range -51 ... +200°C
Temperature stability ±0.05°C
Setting of the temperature display resolution 0.01°C
Temperature display resolution 0.01°C
Permissible ambient temperature +5 ... +40°C
Supply voltage 400V/3PNPE/50Hz (plug 16A CEE) (R507)
Performance data:
Heating power 3 kW
Cooling power
20 °C 2kW, 0°C 1.5 kW, -20°C 1 kW, -40°C 0.26 kW
Refrigerant R507
Global warming potential 3985
Filling weight 1030 g
Carbon dioxide equivalent 4.10455 t
Pump performance Flow rate 22 ... 26 l/min
Pump performance Delivery pressure 0.4 ... 0.7 bar
Dcedpfozgaa Iex Agmok
Maximum suction capacity 0.2 ... 0.4 bar
Viscosity max. 70 cSt
Current consumption 16 A
Electronics
Interfaces Profibus optional
Pt100 External sensor connection integrated
Integrated program generator 6x60 steps
Temperature control ICC
Absolute temperature calibration 3-point calibration
Temperature display VFD
Temperature setting Keypad
Voltage variants 400V/3PNPE/50Hz (plug 16A CEE) (R507)
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Stress test chamber
EspecEHS-221MD
Call
Condition: excellent (used), Espec
Dsdozfy N Tepfx Agmsck
Here we offer an Espec (ThermoTec) stress test chamber.
External dimensions: W x H x D: 860 x 1795 x 1000 mm
Test chamber dimensions: W x H x D: 355 x 355 x 426 mm
2 x 46 liters
Voltage: 230 V 1/N 50 Hz
Rated current: 37 A
Fuses: 250 V, 2 x 3 A
Type: EHS-221MD
Temperature range: +105°C to +142.9°C
Humidity range: 75 to 100% RH
Temperature stability: -+ 0.5 °C
Pressure range: 0 to 2.0 kg/cm²
Heating/pressure build-up time: from 0 to 2.0 kg/cm² in approximately 60 minutes
390 kg
Condition: Used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
7,623 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch Shock Test Chamber
Here we offer you a Vötsch shock test chamber.
Water-cooled
Temperature range: -80°C to +220°C
Warm chamber: +50 to +220
Intermediate chamber: -10 to +90
Cold chamber: -80 to +70
Supply voltage: 400V ±10% 3/N 50Hz
Dsdpfxjzd Uzus Agmeck
Rated current: 30.5 A
Rated power: 13.5 kW
Refrigerant VK: R 404A 3.00 kg p*: 25 bar
Refrigerant TK: R23 15 bar p*: 25 bar
Condition: used
Type: VT 7012 S3
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Stress test chamber
EspecEHS-221M
Call
Condition: excellent (used), Espec
We are offering an Espec (ThermoTec) stress test chamber.
Overpressure and humidity tests at over 100 degrees Celsius in various modes.
Program capacity for 10 samples with 30 steps per sample.
A variety of safety mechanisms: overheating/overpressure protection, detection of water supply failure, complete door locking, and temperature sensor.
Saturated temperature range: 105 to 142.9°C.
Dcjdezd Uy Dopfx Agmsk
Unsaturated temperature range: 105 to 132.9°C.
Humidity range: 50 to 100% RH.
Nominal pressure: 0.196 MPa at 132.9°C and 100% RH.
External dimensions: Width 740 x Height 1553 x Depth 1000 mm.
Test chamber dimensions: Width 355 x Height 355 x Depth 426 mm.
Other features:
With rails and grid.
Test item connections inside the chamber.
Type: EHS-221M
Scope of delivery: See images.
300 kg
Condition: Used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are reserved!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
For vibration tests 530 liters
CTS KlimaprüfschrankTV-70/530 -70°C bis +180°C
Call
Condition: excellent (used), CTS TV-70/530 Climate Test Chamber
Manufacturer: CTS Clima Temperatur Systeme GmbH
Type: TV-70/530
Machine type: Climate test chamber / Shaker chamber
Test chamber volume: approx. 530 liters
For sale is a used climate test chamber from CTS Clima Temperatur Systeme GmbH. The system was developed for combined temperature and vibration tests and is suitable for environmental simulation, material testing, electronics testing, quality assurance, as well as development and stress tests.
Note: Shaker/vibration exciter is not included in the offer.
Technical data
Test chamber dimensions: approx. 850 x 730 x 860 mm (W x D x H)
External dimensions: approx. 1450 x 2250 x 2000 mm (W x D x H)
Weight: approx. 1,200 kg
Temperature range: -70 °C to +180 °C
Heating rate: approx. 5 K/min
Cooling rate: approx. 5 K/min
Djdezd Uq Aspfx Agmock
Refrigerant: R404A / R23
Rated power: 16 kW
Rated current: 29.1 A
Equipment
Shaker chamber for combined tests
Test chamber prepared for vibration applications
Cascade refrigeration system
Temperature testing
Accessories as shown in the pictures
Application areas
Temperature testing
Combined climate and vibration testing
Environmental simulation
Electronics testing
Material testing
Quality assurance
Research and development
Scope of supply
1x CTS TV-70/530 climate test chamber
Scope of supply as shown in the pictures
Condition
Used
Optical condition as shown in the pictures
Shaker/vibration exciter is not included in the offer.
Items, machines or other accessories shown in the pictures that are not explicitly described are not included in the scope of supply.
Scope of supply as shown in the pictures.
Subject to changes and errors in the technical data as well as prior sale.
Listing
Borken
7,623 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80, water-cooled
Cold-heat operation: -75°C ... +180°C
Climate operation: +10...+95°C
Humidity range: 10...98 % RH
Temperature stability, over time: ± 0.2K
Humidity stability: ±1 % RH
Temperature change rate:
Cooling: approx. 1.4 K/min
Heating: approx. 2.5 K/min
External dimensions: Height 1980 mm, Width 1265 mm, Depth 1365 mm
Connections:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/50 Hz
Power: 10.4 kVA
Dcodpfezd Ultex Agmjk
Weight: approx. 720 kg
Refrigerant: R404a / R23
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Environmental test chamber -70°C to +180°C humidity
ThermotronSM-8-8200
Call
Condition: excellent (used), Here we offer you a Thermotron environmental test chamber.
Thermotron environmental test chamber, water-cooled
Working area volume: 227 liters
Temperature uniformity: All models 0.7°C
Temperature range: -70°C to +180°C
Temperature control tolerance: All models 0.3°C
Shipping weight: approx. 400 kg
Internal dimensions: Width 610 mm x Depth 610 mm x Height 610 mm
External dimensions: Width 890 mm x Depth 1240 mm x Height 1850 mm
Humidity range: All models 10% to 98% RH
Humidity control: All models 2.5% RH
Heating time in minutes -65º to 71ºC: 17
Heating time in minutes -65º to 180ºC: 43
Heating time in minutes -40º to 85ºC: 16
Electrical requirements in full load amps 230/3/60: 19
Electrical requirements in full load amps 230/1/60: 25
Electrical requirements in full load amps 220/1/50: 27
Cooling time in minutes 85º to -40ºC: 32
Cooling time in minutes 71º to -65ºC: 54
Cooling time in minutes 180º to -65ºC: 72
Dcjdpfxszd Snrj Agmek
Compressor size: (2) -2 Hp
Operating voltage: 400V 16.7 A
Type: SM-8-8200
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Emissions test chamber
WEISSWT 5,1'/ + 18-45
Call
Condition: excellent (used), Weiss
Here, we offer a Weiss emission test chamber.
Mini - SHED for diurnal loss measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (usable 1600) mm
Housing dimensions: Width 1760 mm x Depth 3100 mm x Height 2790 mm
Maximum floor load: 250 kg
Operating temperature range: +18 °C ... +45 °C (at higher temperatures, SHED operation is only possible without a Tedlar bag)
Temperature range: +18 °C ... +45 °C
Temperature stability: ≤ ±1 K (over time)
Temperature change rate (heating and cooling): approx. 0.5 K/min, without test specimen
Duct connection (air inlet and outlet): ∅ 80 mm, in the rear wall of the chamber
Shut-off valve, gas-tight (air inlet and outlet): ∅ 80 mm, gas-tight, pneumatic operation; scope of supply: connecting flange of the shut-off valve
Cooling water consumption: approx. 0.8 m3/h
Voltage: 230/400 V; 3-phase + N + PE; 50 Hz
Rated power: 4.1 kW Rated current: 14.0 A
Dodpfxozd Slke Agmock
Weight: approx. 2500 kg
Type: WT 5.1'/ + 18-45
Condition: used
Sale from our location
Scope of supply: (Only the Weiss emission test chamber WT 5.1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climate test chamber
Technical data:
Nominal volume of test chamber: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Door: double-leaf, clear opening width 2000 mm, height 1000 mm
Viewing window, heated, 2 pieces, width 500 mm, height 600 mm
Feed-through opening, 1 piece, left side wall, diameter 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Temperature difference, time-dependent ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Dcedpozd Sdmefx Agmjk
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 % RH
Humidity difference, time-dependent ≤ ± 3.0 % RH
Dew point range, intermittently up to -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and dryer refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical connection: 400V 3/N/PE.AC, 50Hz
Power plug: CEE 5-pin, 32 A, with 5.0 m cable
Max. simultaneous power requirement: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Climate test chamber with humidity control
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test chamber.
Feutron Climate Test Chamber
Temperature
Temperature range: -40...90°C
Climatic range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climatic operation: ± 1.0... ± 1.5 K/min
Change rates
Heating: avg. 2.0 K/min
Cooling: avg. 2.0 K/min
Standard IEC 1646 is achievable with testing, solar modules up to max. 160kg weight and nonlinear ramps (setpoint jump)
Drying
Air drying: condensation drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95 % r.h.
Temporal humidity deviation: ≤ ± 3.0... ±5.0 % r.h.
Dew point range: 8...80.9°C
Test Chamber
Test chamber volume: 7.0 m³
Dimensions
Internal dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Swing door DIN right, heated, Width 900 mm x Height 2100 mm
Observation window, heated, with blackout shutter and lockable: Width 500 mm x Height 600 mm
Feedthrough: 2x, right front side, Ø 75 mm
Irradiation unit, test chamber
Opening: 4x in left side wall for SC 2500, each 850 x 700 mm
Irradiated area when using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Refrigeration system: Bitzer compressor, semi-hermetic, 2-stage, air cooled
Condenser: split condenser (outdoor installation, winter control)
Refrigerant: R507 / R23
Temperature control system
Coolant medium Tyfocor / water
Mixing ratio 50/50%
Coolant density: 1.072 kg/dm³
Filling quantity: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply, test chamber
Mains connection: 400V, 3/N/PE, AC, 50Hz
Dcedjzd Sdgspfx Agmjk
Connection type: hardwired
Max. simultaneous power demand: approx. 32.0 kW
Supply fuse: 3 x 63, Char C (A)
Power supply, SolarConstant
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type:
Max. simultaneous power demand: approx. 30.0 kW
Supply fuse: 3 x 63, Char C (A)
Overall external dimensions of the test cell including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber (total): approx. 2700 kg
Condenser empty weight: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Scope of delivery: (see picture)
(Technical data and information are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,623 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here, we offer a shock test chamber.
Water-cooled temperature shock test chamber
Dcsdpfx Aszd R Uwsgmsk
Two-chamber design
Warm chamber:
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -65°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power: 10 kW
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Type: HT 7012 S2
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by phone.
Trust Seal
Dealers certified through Used-Machines

Listing
Borken
7,623 km
Temperature chamber
ThermotronSE-1000-5-5
Call
Condition: excellent (used), Thermotron Temperature Chamber
Here we offer a Thermotron temperature chamber.
Water-cooled
Thermotron temperature chamber SE-1000-5-5
Dimensions of the working area - WxDxH: 102 x 100 x 97 centimeters
Working area volume: 986 liters
Temperature uniformity: ± 0.5°C
Temperature range: -70ºC to 180ºC
Temperature control tolerance: 0.3°C
Installation dimensions - WxDxH: 122 x 188 x 218 centimeters
Electrical requirements 400/3/50 32.4 A
Refrigerant: R-404A / R23
Approximate weight: 862 kg
Type: Thermotron SE-1000-5-5
For your safety as a buyer, please note the following information!
Dcjdpfxszd R S Ns Agmjk
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Heraeus Shock Test Chamber
We offer a shock test chamber here.
Temperature shock test cabinet, water-cooled
Two-chamber design
Warm chamber:
The temperature control of the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 11 K/min
Cold chamber:
The temperature control of the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 2 K/min
Cooling 3 K/min
Test chamber volume 125 liters
Temperature range, warm chamber +50°C to +220°C
Temperature range, cold chamber -80°C to +70°C
Test chamber dimensions: width 470mm, depth 650mm, height 410mm
External dimensions: width 930mm, depth 2115mm, height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Weight: 1000 kg
Dsdpozd R Azjfx Agmjck
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Type: HT 7012 S2
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are reserved!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
7,623 km
Temperature chamber
WEISSWT1-340/30
Call
Condition: excellent (used), Weiss Temperature Chamber
Here we offer a Weiss temperature chamber.
Converted to R452a
Weiss Temperature Chamber, Air-Cooled
Dcjdpjzd Rw Sjfx Agmek
Temperature range: from -30°C to 180°C
Temperature change rate, cooling: 1.6 K/min
Temperature change rate, heating: 2.1 K/min
Test chamber dimensions: width 550 mm x depth 750 mm x height 800 mm
Housing dimensions: width 800 mm x depth 1500 mm x height 1800 mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 4.9 kW, rated current: 9 A
Refrigerant: R452a
Weight: 515 kg
Type: WT1-340/30
For your safety as a buyer, please note the following information:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature control chamber.
Heraeus Vötsch temperature control chamber, water-cooled
Test chamber volume: 110 liters
Test chamber dimensions: Width 560 mm, Depth 350 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1030 mm, Height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Dedezdtd Ijpfx Agmsck
Temperature gradient: 1 to 3 K
Temperature change rate (cooling): 3.2 K/min
Temperature change rate (heating): 3.5 K/min
Refrigerant: R-404 A / R 23
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 1.8 kW
Rated current: 12 A
Type: VT 7011
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
We make it easier for you to find: "weiss temperature test chamber 1000 liters"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time












































































































































































































