Used Rs-Simulatoren Kkm 110/45 -40°C Bis +120°C for sale (80,730)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Walk-in climate chamber with humidity control
RS-SimulatorenKKM 110/45 -40°C bis +120°C
Call
Condition: excellent (used), RS Simulators
Type: KKM 110/45
Manufacturer: RS-Simulatoren, water-cooled
Climate chamber 110m³ incl. condenser
The KKM 110/45 type belongs to the TKM/KKM modular design of RS-Simulatoren,
meaning it is a climate chamber with a modular structure that is assembled on-site.
This design offers:
Modularity: Individual segments are pre-assembled and installed at the customer's location.
This makes retrofitting (more depth or additional modules) as well as later relocation straightforward.
Technical data climate chamber:
Manufacturer: RS-Simulatoren Prüf- und Messtechnik GmbH
Type: KKM 110/45
External dimensions: 6200 x 9400 x 3400 (W x D x H in mm) incl. technical attachments
Internal dimensions: 5900 x 7000 x 2960 (W x D x H in mm)
Chamber door (double-leaf) 3600 x 2930 (W x H in mm)
Personnel door (single-leaf) on side wall 1880 x 900 (H x W in mm)
Feedthroughs: 8 x Ø120mm (4x left & 4x right)
Windows: 1x (460 x 550mm) in the front chamber door, heated
1x (1260 x 1000mm) in the left side wall, heated
Fodpfx Ajzizldeptjpi
Temperature range: -40°C to +120°C
Time deviation: ± 0.8K – 1.5K according to DIN 50011 in an empty test chamber
Humidity range: 10% to 95%
Humidity tolerance: +/- 5.0%
Refrigerant: 2x R404A 52kg
2x R23 17kg
Temperature change rate:
Heating: 1.0 K/min
Cooling: 1.0 K/min
Max. surface load 500kg / m²
Electrical data:
Voltage: 3x400V/N/PE Current: 340A
Weight: approx. 2,000 kg
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerants
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will gladly answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Walk-in climate chamber with humidity control
RS-SimulatorenKKM 40/45S
Call
Condition: excellent (used), Here we offer you a walk-in climate chamber.
Manufacturer: RS-Simulatoren, water-cooled
The chamber can be disassembled into three parts for transportation (bolted construction).
Temperature range: -30°C to +100°C
Refrigerants: 20kg R-404A + 20kg R-452A
External dimensions (approx.): Width 3,920 mm, Depth 7,350 mm, Height 2,600 mm
Test chamber/internal dimensions (approx.): Width 3,500 mm, Depth 5,400 mm, Height 2,110 mm
Electrical data: 68kW rated power
Voltage: 3x400V/PE, Current: 135A
Model: KKM 40 / 45 S
Further technical details will follow!
Fodpozgablsfx Aptopi
For your peace of mind as a buyer, please note the following:
We carry out the following procedures on all chambers offered:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful checks, the chambers undergo a documented test run
Condition: used
Scope of delivery: see picture
(Subject to changes and errors in the technical data and specifications!)
For further questions, feel free to contact us by phone.
Listing
Borken
7,623 km
Vibration temperature test chamber
RS-SimulatorenVTS 600/45 RS -45°C...+180°C
Call
Condition: excellent (used), We are offering a temperature test chamber here.
Water-cooled
Temperature range: -45°C to +180°C
Fpjdpfsziygmjx Aptoi
External dimensions: Width 1300 mm x Height 2100 mm x Depth 2250 mm
Test chamber dimensions: Width 840 mm x Height 840 mm x Depth 840 mm
Unit section: Width 2300 mm x Height 2000 mm x Depth 1300 mm
Average heating rate: approx. 3 K/min
Average cooling rate: approx. 2 K/min
Power consumption: 15 A
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 1000 kg
Type: VTS 600/45 RS
Refrigerant: R452
Condition: used
Scope of delivery: (see picture)
(Specifications are subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
7,623 km
Temperature shock chamber 580 liters
RS-SimulatorenST2K 1000/55 -70°C bis +180°C
Call
Condition: excellent (used), RS-Simulators Temperature Shock System ST2K 1000 / 55
The system was regularly serviced and maintained by the manufacturer until it was decommissioned.
Device Data
Manufacturer: RS-Simulators
Type: ST2K 1000 / 55
Design: Temperature Shock System
Cooling: water-cooled
Description
Used temperature shock system for standard-compliant thermal shock testing.
Suitable for material, component, and reliability testing.
Application in industry, automotive, research, and quality assurance.
System Description
2 separate temperature chambers (hot / cold)
Automatic horizontal test basket transfer
Fast changeover for temperature shock tests
Temperature ranges
Hot chamber: +40 °C to +180 °C
Cold chamber: -70 °C to +100 °C
Time deviation: ±0.8 K
Test chamber
Volume: approx. 580 liters
Internal (W x H x D): approx. 1070 x 680 x 800 mm
Max. load: approx. 150 kg
Power supply
400 V / 3~ / N / PE / 50 Hz
Power: max. 33 kVA
Current consumption: max. 65 A
Media connections
Cooling water: G 1", approx. 3 bar (max. 10 bar)
Cooling water requirement: max. 3.2 m³/h
Cooling water return: unpressurized
Compressed air: NW 7.2, 4–10.5 bar
Dimensions:
External (W x H x D): approx. 2800 x 2400 x 2200 mm
Fpsdpfxey H Igfe Aptsi
Weight: approx. 2800 kg
Equipment:
Horizontal basket movement
C-rails in the test chamber
Large test basket (>1000 mm)
Observation window
Internal lighting
Controller SE-604
Program operation and data logging
RS232 interface
Refrigeration system
Refrigerant: R449A / R23
R449A: approx. 8.0 kg
R23: approx. 2.5 kg
Operating data:
Operating hours: approx. 4,500 hours
Sound level: approx. 67 dB(A)
Environmental conditions
Temperature: +12 °C to +30 °C
Humidity: 25 % to 75 % rel. humidity
Scope of supply:
RS-Simulators Temperature Shock System ST2K 1000 / 55
Scope of supply as shown in the pictures
Functional test
Refrigerant service
Leakage test
Condition: Used.
Condition: see pictures.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to changes and prior sale.
If you have any questions, please contact us.
Listing
Borken
7,623 km
Climatic test chamber with humidity, 600 liters
RS-SimulatorenKSS600/75-10K -75°C bis +180°C
Call
Condition: excellent (used), RS-Simulators Climate Chamber KSS 600/75-10K
Device Data
Manufacturer: RS-Simulators Prüf- und Messtechnik GmbH
Type: KSS 600/75-10K
Design: Climate test chamber / Environmental simulation chamber
Cooling: Water-cooled
Description
Used climate test chamber from RS-Simulators.
Fedoy H Ib Aspfx Aptspi
Suitable for temperature tests, climate tests, material and aging tests.
Application in industrial testing and measurement.
Technical Data
Temperature range: -75 °C to +180 °C
Temperature change: Heating/cooling approx. 10 K/min
Test chamber volume: approx. 600 liters
Dimensions
Internal (W x D x H): 840 x 840 x 840 mm
External (W x D x H): 1200 x 1600 x 1995 mm
Electrical Data
400 V / 3~ / N / PE
Current consumption: approx. 55 A
Refrigeration System
Refrigerant: R404A / R23
R404A: 6.0 kg
R23: 3.0 kg
Weight
approx. 1400 kg
Equipment
RS-Simulators control panel / operating panel
Program operation
Observation window
Temperature monitoring in the test chamber
Operating hour counter
Side feed-through
Robust industrial design
Scope of delivery
RS-Simulators climate chamber KSS 600/75-10K
Scope of delivery as shown in the pictures
Functional test
Refrigerant service
Leak test
Condition: Used.
Condition: See pictures.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to changes and prior sale.
If you have any questions, please do not hesitate to contact us.
Listing
Borken
7,623 km
Climatic chamber
RS-SimulatorenKKC 22/45
Call
Condition: good (used), RS Simulators
Type: Walk-in Climate Simulation Chamber KKC 22/45
Technical specifications:
Temperature range: -40...+120 °C
Temperature tolerance: +/- 1.5°C
Temperature change rate: 1 K/min
Humidity range:
10...approx. 95% r.h.
Humidity tolerance:
+/- 5.0% r.h.
Dimensions:
Test chamber volume: 22 m³
External dimensions (W x D x H): approx. 2600 mm x 6400 mm x 2800 mm
Test chamber (W x D x H): approx. 2200 mm x 4700 mm x 2300 mm
Door opening (W x H): approx. 2200 mm x 2300 mm
Fedpfx Apszg Txdetjpi
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data!)
We are happy to answer further questions by phone.
Listing
Borken
7,623 km
Climatic chamber
RS-SimulatorenKKC 22/45L
Call
Condition: good (used), RS Simulators
Type: Walk-in Climate Simulation Chamber KKC 22/45L
Technical Data:
Temperature range: -40...+120 °C
Temperature tolerance: +/- 1.5°C
Temperature change rate: 1 K/min
Humidity range:
10...approx. 95% r.H.
Humidity tolerance:
+/- 5.0% r.H.
Dimensions:
Test chamber volume: 22 m³
Fedpfozg Txkjx Aptspi
External dimensions (W x D x H): approx. 2600 mm x 6400 mm x 2800 mm
Test chamber (W x D x H): approx. 2200 mm x 4700 mm x 2300 mm
Door opening (W x H): approx. 2200 mm x 2300 mm
Year of manufacture: 2009
Technical data for solar simulation:
Control module: Mitronic STB1-8
Number of lamps: 8
Ballast unit: Mitronic CP2k5 – 2ZS
Ignition unit: Hönle
Lamp type: OSRAM Powerstar HQI 2000W W/D/S
Condition: used / second-hand
Scope of delivery: (see image)
(Specifications subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
7,621 km
Vötsch climatic test chamber Fitotron HGC1014
Vötsch Klimaprüfschrank 5°C bis +45°Fitotron HGC 1014 V Schrank 3 mit Bel.
Condition: excellent (used), functionality: fully functional, Year of construction: 2012, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range +5°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range +5°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Fpodpfxjvz U Ero Aptji
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
7,623 km
Thermal shock test chamber
RS-SimulatorenST2K320/45 K
Call
Condition: excellent (used), RS Simulators
Type: ST2K320/45 K
Shock test system, water-cooled
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity levels in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20% to 98% (± 2 to 5%) relative humidity
Humidity: 25% to 75% relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
Fpodpfx Apezgbutstji
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Temperature shock test chamber
RS-SimulatorenST2K320/45
Call
Condition: excellent (used), RS Simulators
Type: ST2K320/45
Water-cooled shock testing system
Operating climate range
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions: Width 1100 mm, Height 2300 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 850 kg
For your safety as a buyer, please note the following information:
Fpedpezgbumsfx Aptoi
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are reserved!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
7,623 km
Temperature test chamber
RS-SimulatorenTS 150/45 (50)
Call
Condition: excellent (used), RS Simulators
Here we offer a temperature testing chamber.
Air-cooled
Temperature range: -50°C to +100°C
Test chamber dimensions: Width 520 mm x Height 520 mm x Depth 500 mm
External dimensions: Width 820 mm x Height 1750 mm x Depth 1300 mm
Power consumption: 13.5 A
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 800 kg
Type: TS 150/45 (50)
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
Fodpfx Apozdtc Rjtspi
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature test chamber
RS-SimulatorenTS 600/45 EX
Call
Condition: excellent (used), RS Simulators
We offer a test cabinet here.
Water-cooled
Temperature range: -40°C to +180°C
Test chamber dimensions: 850mm x 850mm x 800 mm (W x H x D)
External dimensions: 1100mm x 1850mm x 1500mm (W x H x D)
Power consumption: 13.5 A
Refrigerant: R404A
Connection voltage: 3x400V/N/PE 9A
Weight: approx. 750kg
Type: TS 600/45
Explosion-proof operation not tested
However, max. 160°C in this condition
Fpedpfx Aszdn Stjptji
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Remscheid
7,683 km
Control unit
IndramatMAC090B-0-JD-2-C / 110-A-1 Permanent Magnet Motor SN: MAC090-80045
Call
Condition: ready for operation (used), Indramat MAC090B-0-JD-2-C / 110-A-1 Permanent Magnet Motor, Serial No.: MAC090-80045, used, in good condition, 100% functional, scope of delivery as shown in the photos.
Fsdpfx Apoy T Unpstepi
Listing
Remscheid
7,683 km
Control unit
IndramatStator für MAC 90A-0-RD-2-C / 110-A-0 Drehstromservomotor SN: 13545
Call
Condition: ready for operation (used), Stator for Indramat MAC 90A-0-RD-2-C / 110-A-0 three-phase servo motor, serial number: 13545, used, in good condition, 100% functional, scope of delivery as shown in the photos.
Fodpfey T Dnrsx Aptopi
Listing
Borken
7,623 km
Climatic chamber temperature and humidity
EspecPL-3KPH -40°C bis 180°C
Call
Condition: excellent (used), ESPEC Climate Testing Chamber PL-3KPH
Device Data
Manufacturer: ESPEC
Type: PL-3KPH
Design: Climate Testing Chamber
Cooling: Air-cooled
Description
Used climate testing chamber from ESPEC.
Fedpfx Apjy H H Iuotepi
Suitable for temperature and humidity testing.
Used in research, development, and quality assurance.
Operating Status
Display: STOP / ready for operation.
Technical Data
Model: PL-3KPH
Test chamber volume: approx. 400 liters
Temperature range: -40 °C to +180 °C
Temperature change rate (heating): approx. 3.4 K/min
Temperature change rate (cooling): approx. 1.7 K/min
Temperature stability (-40 °C to +100 °C): ±0.3 K
Temperature stability (+100.1 °C to +150 °C): ±0.5 K
Temperature stability (+150.1 °C to +180 °C): ±1.0 K
Humidity range: 20 to 98 % RH
Humidity stability: ±2.5 % RH
Dimensions
Internal (W x H x D): 600 x 850 x 800 mm
External (W x H x D): 1010 x 1690 x 1195 mm
Electrical Data
400 V / 3~ / 50 Hz
Refrigeration System
Refrigerant: R404A
Air-cooled (no external water connection required)
Weight approx. 350 kg
Equipment
Touchscreen control panel
Program and constant operation
BTHC temperature and humidity control
Observation window
Stainless steel test chamber
Internal lighting
Cable gland
Overheating protection
Hour meter
Industrial design
Scope of supply
ESPEC Climate Testing Chamber PL-3KPH
Scope of supply as shown in the images
Service before delivery (optional)
Functional test
Refrigerant service
Leakage test
Test run with protocol
Condition
Used.
Condition see images.
Note
Loading and transport can be arranged upon request.
Subject to changes and prior sale.
If you have any questions, please do not hesitate to contact us.
Listing
Borken
7,623 km
For rapid temperature changes
Binder WechselklimaschrankMK 240 -40°C bis 180°C
Call
Condition: excellent (used), Binder Temperature Test Chamber
Type: MK240-400V
Manufacturer: Binder
For sale is a Binder MK 240 temperature test chamber designed for professional heat and cold testing in industrial settings, research, development, and quality assurance.
The temperature test chambers from Binder’s MK series are particularly suited for cyclic temperature tests and reproducible testing under defined environmental conditions.
This test chamber enables temperature testing within a range from -40 °C to +180 °C, providing an efficient alternative to custom-built solutions.
Technical specifications:
Temperature range: -40 °C to +180 °C
Test chamber volume: approx. 228 liters
Temperature performance data:
Spatial temperature deviation: 0.1 to 1.2 ± K
Temporal temperature deviation: 0.1 to 0.5 ± K
Heating rate: approx. 5.0 K/min
Cooling rate: approx. 4.5 K/min
Cooling time from +180 °C to -40 °C: approx. 110 minutes
Test chamber:
Internal dimensions: approx. 735 x 700 x 443 mm (W x H x D)
Dimensions:
External dimensions: approx. 1115 x 1710 x 925 mm (W x H x D)
Load capacity:
Max. load per shelf: approx. 30 kg
Max. total load: approx. 70 kg
Features:
2 x access ports Ø 70 mm
1 door
2 standard shelves / up to a maximum of 6 shelves possible
Electrical data:
Rated voltage: 400 V
Line frequency: 50 Hz
Rated power: approx. 4.0 kW
Circuit protection: 16 A
Phases: 3~
Fedpfxoy Nicmj Aptjpi
Weight:
Approx. 320 kg
Condition:
Used
Scope of delivery:
As shown in images
Viewing by appointment possible.
Loading can be arranged.
Sale without warranty.
(Specifications and technical details subject to change and error.)
Listing
Borken
7,623 km
Walk-in volume 5 m³
Weiss Technik Klima-PrüfkammerWK 5/55-120 -55°C bis +120°C
Call
Condition: excellent (used), Weiss
Model: WK 5/55-120
Weiss Technik Climate Test Chamber WK 5/55-120
-55°C to +120°C / 5 m³ | Year of manufacture: 2016
The system is water-cooled, high-performance, and designed for continuous professional operation.
For sale is a professional climate test chamber from Weiss Technik, model WK 5/55-120, manufactured in 2016.
This unit is ideal for temperature, climate, and material testing in industrial, research, and development applications. With a temperature range from -55°C to +120°C and a humidity range from 10–95% RH, the chamber covers a broad range of testing scenarios. The spacious test chamber of approximately 5 m³ allows for testing of larger components or assemblies.
Technical highlights:
- Temperature range: -55°C to +120°C
- Climatic range: 10–95% RH
- Heating/cooling rate approx. 1.5 K/min
- Requires water cooling
Fedpfx Asziztuoptjpi
Technical data:
Manufacturer: Weiss Technik GmbH
Model: WK 5/55-120
Year of manufacture: 2016
Dimensions / Volume
- Test space volume: approx. 5 m³
- External dimensions (W×D×H): approx. 1900 × 4410 × 2621 mm
- Internal dimensions (W×D×H): approx. 1600 × 1700 × 2000 mm
Temperature range: -55 °C to +120 °C
- Heating/cooling rate: approx. 1.5 K/min
- Climatic range: 10 – 95 % RH
- Dew point range: +4 °C to +85 °C
Electrical data:
- Mains connection: 3/N/PE AC 400V ±10% 50Hz
- Rated power: approx. 47 kW (depending on configuration)
- Rated current: 71 A
- Customer-side fuse: 63 A
Cooling water:
- Water cooling required
- Maximum cooling water consumption: approx. 7 m³/h
- Inlet temperature: approx. 20 °C
Noise level: approx. 76 dB(A)
Weight: approx. 4,600 kg
Scope of delivery:
- Weiss Technik climate test chamber WK 5/55-120
- Control system
- Operating manual (German)
- Nameplate & documentation
Condition: used
Scope of delivery: (see photo)
(Subject to change and error in technical data! All information provided without liability.)
Listing
Borken
7,623 km
Walk-in climate simulation chamber
TIRAKB 127 TCZ 4022 S -2K -40 bis +140°C
Call
Condition: excellent (used), TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation chamber
System Structure:
The unit consists of the following main assemblies:
- Walk-in, insulated chamber
- Air handling room
- Humidification system
- Machinery room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
- Cooling rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% RH (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% RH, measured in supply air
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% RH (without thermal test chamber load; with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
Fpjdpfx Apjzizk Hotji
- Test chamber (WxDxH): approx. 2260 x 4648 x 2260 mm
- External dimensions (WxDxH): approx. 2660 x 6460 x 2800 mm
- Clear door passage test chamber door (WxH): 2260 x 2260 mm
- Climate module KB 127 (WxDxH): 1700 x 800 x 1400 mm
- Control cabinet (WxDxH): 800 x 500 x 2000 mm
Design:
- Airflow: Supply air via perforated plate at the rear wall, ceiling area; exhaust air via perforated plate at the rear wall, floor area
- Temperature control: Direct cooling via evaporation of refrigerant in a finned heat exchanger; heating via electric resistance heater
- Dehumidification: Direct dehumidification via refrigerant evaporation in a heat exchanger
- Interior lining: Stainless steel
- Exterior cladding: Galvanized, plastic-coated steel sheet
- Floor: Stainless steel, floor load 15,000 N/m²
- Wheel load (contact area ≥4 cm²): 1,500 N/wheel
- Door: Double-leaf, stainless steel, externally coated with viewing window (WxH): 1000 x 1000 mm
- Test area lighting: 4 spotlights, 500 W each
- Insulation: Dual-layer insulation, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc): Bitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc): EDB 40
Color scheme:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidification unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10%, 3/PE N, 50Hz
- Rated power: 95 kW
- Rated current: 150 A
Listing
Borken
7,623 km
Temperature cabinet 2240 liters
MytronT2240 –40°C bis +100°C
Call
Condition: used, mytron
Type: T2240
Water-cooled temperature chamber
Technical Data:
External dimensions: Width 1435 mm, Height 1955 mm, Depth 2590 mm
Test chamber dimensions: Width 1050 mm, Height 1400 mm, Depth 1600 mm
Test chamber volume: approx. 2240 l
Cable entry ports:
2 x 100 mm right
2 x 100 mm left
Temperature range: –40 °C to +100 °C at 23 °C ambient temperature
Temporal temperature constancy: +/- 0.5 °K
Spatial temperature constancy: +/- 1.0 °K
Cooling: water cooling
Inlet and outlet: 1" internal thread
Cooling water shut-off via solenoid valve when unit is OFF
Fault indicator for refrigeration unit errors
Cooling water consumption: inlet temperature approx. 15 °C, approx. 15 l/min,
Fpodszizg Uepfx Aptsi
outlet temperature approx. 22 °C (with continuous cooling approx. 27 °C)
Power connection: 3NPE AC 50 Hz 400 V, 32 A CEE plug
Power consumption: approx. 6.5 kVA
Fusing: 3 x 20.0 AT, 3 x 10.0 AT
Lighting: 25 watts each, left and right sides of test chamber
Exhaust connection: DN 100 mm plug-in system
Safety device: electronic over-temperature protection, fixed setting
Smoke detection with alarm sound
Viewing window: five-layer glass, 130 x 360 mm
Refrigerant: R 404 A, approx. 10 kg
Weight: approx. 850 kg
Condition: used
Scope of delivery: (see picture)
(Specifications subject to change and error!)
If you have further questions, we would be glad to answer them by phone.
Listing
Borken
7,623 km
Climate test chamber with humidity, 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Weiss
Model: WK3-340/40
Weiss Climate Test Chamber, Air-Cooled
Temperature Testing
Volume: 335 liters
Test Chamber Dimensions:
Internal Dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External Dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum Temperature: –42°C
Maximum Temperature: +180°C
Temperature Change Rate, Cooling: 4 K/min
Temperature Change Rate, Heating: 3.2 K/min
Temperature Deviation Over Time: ± 0.1 to ± 0.5 K
Temperature Uniformity Spatially: ± 0.5 to ±1.5 K
Climate Testing:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% RH
Temperature Deviation Over Time: ± 0.1 to ± 0.3 K
Temperature Uniformity Spatially: ± 0.5 to ± 1 K
Humidity Deviation Over Time: ± 1 to ± 3 % RH
Halogen Lamp: 2 x 24V, 50W
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Power: 4.1 kW, Rated Current: 14 A
Refrigerant: R-404A
Weight: approx. 515 kg
For your security as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
Fpsdpfxsziyygo Aptoi
(Changes and errors in the technical data and specifications reserved!)
Further questions can be answered by phone.
Listing
Borken
7,623 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Water-Cooled Temperature Test Chamber
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
Fsdpjziyxpjfx Aptopi
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
Trust Seal
Dealers certified through Used-Machines

Listing
Borken
7,623 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), We are offering a Weiss temperature test chamber for sale.
Weiss Temperature Test Chamber with S!MCON / 32-controller, water-cooled
Control Unit: "Touchpanel"
All control and operation commands can be initiated by simply touching the function symbols on the "Touchpanel" control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for floor unevenness and to provide adequate ventilation for the machine section.
Cable Ports
Cable ports are installed on both the right and left sides of the test chamber. These allow measurement cables and test devices to be routed into the test space. Ports included as standard:
- R1: NW 125 mm
- L1: NW 50 mm
(The refrigerant has been converted to R-452A)
Test Chamber Volume: approx. 600 liters
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Temperature Test Data:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
Maximum thermal compensation: 2500 W
Operating Data:
- Test chamber lighting: Halogen bulb 2 x 24V, 50W
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated current: 15 A; Rated power: 7.8 kW
- Fuse (on-site): 16 A slow-blow
- Sound pressure level: approx. 58 dB(A) (measured 1 m in front, 1 m height)
- Refrigerant: R-452A
- Weight: 620 kg
Fpjdpfjziyb Rex Aptsi
Type: WT3-600/40
Important information for your safety as a buyer!
The following steps are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
7,623 km
Climatic chamber temperature and humidity
EspecPL-2KPH -40°C bis 180°C
Call
Condition: excellent (used), Espec
Model: PL-2KPH
ESPEC PL-2 KPH Climate Chambers, Air-Cooled
Fedpfx Apezimfpetspi
Temperature range: -40°C to +180°C
Humidity range: approx. 10 to 98% RH
Dependence on temperature range and humidity fluctuations:
± 2.5% RH over time, ± 3.0% RH
Internal dimensions (WxHxD): 500 × 750 × 600 mm
External dimensions (WxHxD): 910 × 1590 × 973 mm
Microprocessor control with 10 pre-set international test standards and 20 freely programmable memory slots,
as well as built-in timer with programmable start/stop automation and error code display.
Programming via touch screen.
Alarm display (audible and visual).
Device protection against overtemperature:
Overtemperature protection with two switching contacts
Illumination of testing chamber
Operating hours counter
Test chamber volume: 225 liters
Net weight: 300 kg
Electrical connection: 400 V 3/N 50 Hz,
Plug: CEE 16 A, max. current: 11.0 A
Refrigerant: R404A
Scope of delivery: Espec climate test chamber
Buyer information for your security:
The following procedures are carried out in advance on the chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photos)
(Specifications and technical details subject to change and errors!)
If you have further questions, please feel free to contact us by phone.
Listing
Borken
7,623 km
Climatic test chamber with humidity, 600 liters
CTSC-40/600 -40 bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber Type: C -40/600, Air-Cooled
(converted to R-452a refrigerant)
Test chamber volume: 600 liters
Temperature tests:
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K over time (at stabilized condition)
- Average temperature rate of change (without test load and radiant heat):
- Heating: 2.5 K/min
- Cooling: 3.0 K/min
- Maximum radiant heat input: 2500 W at +20°C
Climatic tests:
- Climate range / Technical data:
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
- Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
- Humidity consistency II: ±1% r.h. to ±3% r.h.
- Temperature consistency: ±0.1 K to ±0.3 K
Chamber internal dimensions (approx.): Height: 850 mm, Width: 850 mm, Depth: 830 mm
External dimensions (approx.): Height: 1900 mm, Width: 1115 mm, Depth: 1850 mm
Fodjziizgepfx Aptjpi
Refrigerant: R-452A
Power connection: 400V 3/N 50Hz
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for your purchase!
The following checks and procedures are performed on all our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in the technical data and specifications!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
7,623 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Fodpeziixrsfx Aptepi
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Weight: approx. 2,100 kg
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
We make it easier for you to find: "rs-simulatoren kkm 110/45 -40°c bis +120°c"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time




























































































































































































































