Used Temperature Cabinet 990 Liters for sale (18,036)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss temperature chamber WT11-1000/40, temperature range -40°C to +180°C, 990 liters
WeissWT11-1000/40
Call
Condition: used, Weiss
Type: WT11-1000/40
Weiss temperature chamber, air-cooled, with Weiss condenser cooler
Test chamber volume approx. 990 liters
Data for temperature tests:
Temperature range -40°C to +180°C
Temporal temperature deviation in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature gradient (according to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 4 K/min
Cooling 3 K/min
Heat compensation max. 4500 W
Feedthroughs installed as standard
R1: NW 125 mm
L1: NW 50 m
Itjdpfxezfzame Ag Asn
Dimensions:
Test chamber dimensions: Width 1100 mm x Depth 950 mm x Height 950 mm
Housing dimensions: Width 1390 mm x Depth 1525 mm x Height 1995 mm
Maximum load (evenly distributed over the area) of the test chamber floor 150 kg
Per insert shelf 50 kg
Total load of the shelf supports 100 kg
Data for operation:
Test chamber lighting: Halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 11.5 kW
Rated current 22 A
Heat dissipation water-cooled test cabinets max. heat dissipation to the environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: (converted to R-452a)
Weight: approx. 840 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss Temperature Chamber WT11-1000/70/5 Temperature range: -70°C to +180°C, 990 liters
WeissWT11-1000/70/5
Call
Condition: used, Weiss
Type: WT11-1000/70/5
Weiss temperature chamber, air-cooled, with Weiss condenser cooler
Test chamber volume approx. 990 liters
Itodpfezfy Rwex Ag Asn
Data for temperature tests:
Temperature range -70°C to +180°C
Temporal temperature deviation in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature gradient (according to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 5 K/min
Cooling 5 K/min
Heat compensation max. 2750 W
Feedthrough installed as standard
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x Depth 950 mm x Height 950 mm
Housing dimensions: Width 1390 mm x Depth 1525 mm x Height 1995 mm
Maximum load (evenly distributed over the area) of the test chamber floor 150 kg
per insert grid 50 kg
Total load of the grid supports 100 kg
Data for operation:
Test chamber lighting: Halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 27.0 kW
Rated current 42.02 A
Heat dissipation water-cooled test cabinets max. heat dissipation to the environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: (converted to R-452a)
Weight: approx. 960 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss temperature chamber WT3-1000/40, 990 liters, temperature range -40°C to +180°C
WeissTemperaturprüfschrank
Call
Condition: used, Weiss
Type: WT3-1000/40
Weiss temperature testing cabinet with S!MCON / 32 control, water-cooled
Control panel: "Touch Panel"
All control and operating commands can be initiated on the "Touch Panel" control panel by simply touching the function symbols.
Adjustable feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing cabinet is equipped with adjustable feet.
Isdpfx Agezgbt No Ajtn
Feedthroughs
The testing cabinet is equipped with feedthroughs on the right and left sides. These allow measuring cables and testing equipment to be routed into the testing chamber.
Feedthroughs installed as standard
R1: 125 mm
L1: 50 mm
Testing chamber volume: approx. 990 liters
Testing chamber dimensions: Height 950 mm, Width 1100 mm, Depth 950 mm
External dimensions: Height 2000 mm, Width 1415 mm, Depth 2105 mm
Data for temperature tests:
Temperature range: -40 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 4500 W
Data for operation:
Testing chamber lighting: Halogen bulb 2x 24V, 50W
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 22.0 A, Rated power 11.5 kW
Fuse, to be provided by the customer: 32 A, slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front, 1 m height: 56 dB(A)
Refrigerant: R-404A
Weight: 840 kg
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have on the phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Vötsch Temperature Test Chamber VT³ 4100 -40°C to +180°C, 990 liters
VötschVT³ 4100
Call
Condition: used, Vötsch
Type: VT³ 4100
Water-cooled temperature test chamber
S!MCON/ (with touch panel)
Features of this controller:
Color touchscreen with intuitive menu (usually 5.7" or larger)
Programming of temperature/humidity profiles with ramps and dwell times
Data acquisition & logging (e.g., temperature profile, alarms)
USB port for data export (CSV, optionally S!MPATI-compatible)
Network interface (Ethernet) for remote monitoring and control
User management with password protection
Interfaces: Potential-free contacts, optionally Modbus or Profibus
Itjdpfjziyxpjx Ag Aon
VT³ 4100 – Technical data (temperature test chamber)
Test volume: 990 liters
Temperature range: -40 °C to +180 °C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation within the chamber: ±0.5 to ±1.5 K
Temperature gradient: 1 to 3 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat dissipation capacity (max): 4500 W
Calibration values: +23 °C and +80 °C
Internal dimensions (W×D×H): 1100 × 950 × 950 mm
External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feedthroughs:
The test chamber is equipped with feedthroughs on the left and right sides.
These allow measurement cables and testing equipment to be placed in the test chamber.
1 x L1 NW 50 mm
1 x R1 NW 125 mm
3 x R1 NW 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant R452A
Weight: 920 kg
For your security as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,614 km
Vötsch VT 7100 temperature test chamber -70°C to +180°C, test chamber volume 990 liters
VötschVT 7100
Call
Condition: excellent (used), Vötsch VT 7100 Temperature Test Chamber -70°C to +180°C
Features
• Touch panel
• Microprocessor-controlled monitoring and control system MINCON/32
• Extremely low noise level
• Protection of test specimens through independent temperature measurement
• Maintenance-friendly design
• Door with window (including test chamber lighting)
• Streamlined air flow
Manufacturer: Weiss Vötsch
Type: Temperature test chamber
Model: VT 7100
Control system: MINCON / 32
Operating unit: Touch panel
Test chamber volume: 990 l
Temperature range: -70 °C to +180 °C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.1 to ±0.5 K
Temperature change rate (cooling): 2.2 K/min
Temperature change rate (heating): 3 K/min
Electrical connection: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 13.8 kW
Rated current: 29 A
Weight: 910 kg
Dimensions of the test chamber:
Width: 1100 mm
Depth: 950 mm
Height: 950 mm
External dimensions:
Width: 1390 mm
Depth: 1855 mm
Height: 1995 mm
Itsdeph Uzxopfx Ag Aon
You can find more items – new and used – in our shop! International shipping costs available upon request!
Success:
Your message has been sent.
Listing
Borken
7,623 km
Mytron temperature cabinet T2240 temperature range –40°C to +100°C, 2240 liters
mytronTemperaturschrank
Call
Condition: used, mytron
Type: T2240
Water-cooled temperature chamber
Technical data:
External dimensions: Width 1435 mm, Height 1955 mm, Depth 2590 mm
Dimensions of the test chamber: Width 1050 mm, Height 1400 mm, Depth 1600 mm
Volume of the test chamber: approx. 2240 l
Cable feed-through opening:
2 x 100 mm on the right
2 x 100 mm on the left
Temperature range: -40 °C to +100 °C at 23 °C ambient temperature
Temporal temperature stability: +/- 0.5 °K
Spatial temperature stability: +/- 1.0 °K
Cooling: Water cooling,
Inlet and outlet 1" internal thread
Cooling water shut-off via solenoid valve when the unit is OFF
Fault indication in case of refrigeration machine failure
Cooling water consumption: Inlet temperature approx. 15 °C, approx. 15 l/min,
Outlet temperature approx. 22 °C (approx. 27 °C in continuous cooling)
Mains connection: 3NPE AC 50 Hz 400 V, 32 A CEE plug
Power consumption: approx. 6.5 kVA
Fuses: 3 x 20.0 AT, 3 x 10.0 AT
Lighting: 25 watts each on the left and right sides of the test chamber
Exhaust connection: DN 100 mm plug-in system
Safety device: Electronic overtemperature protection, permanently set
Flue gas monitoring with audible alarm
Viewing window: Five-pane glazing 130 x 360 mm
Refrigerant: R 404 A, approx. 10 kg
Weight: approx. 850 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
Itsdpfx Agszizg Us Asn
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Heraeus Vötsch temperature test chamber VTS 7033 -70°C to +180°C approx. 570 liters
Heraeus VötschHeraeus Vötsch
Call
Condition: used, Heraeus Vötsch
Type: VTS 7033
Vötsch temperature testing cabinet VTS 7033, water-cooled
Temperature range: -70°C to +180°C
Iodpfx Agszd Sf Ds Aetn
Temporal temperature deviation: ± 0.5 K
Spatial temperature deviation: ± 1.5 K
Heating rate: 7.5 K/min
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x Depth 800 mm x Height 870 mm
Housing dimensions: 1080 mm x 1710 mm x 1950 mm
Side feed-throughs: 12 cm and 13 cm
Voltage: 400V +6/-10%, 3/N, 50Hz
Rated power: 9.5 kW, Rated current: 22 A
Refrigerant: R404A / R23
Approx. 570 liters, Weight: 580 kg
For your peace of mind as a buyer, please note the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss Climate Test Chamber WK3-600/0-M, 600 liters, with humidity control, temperature range -5°C to
WeissKlimaprüfschrank
Call
Condition: used, Weiss
Type: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Type series WK3-../0
with SIMPAC* control system
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Data for operation:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Fuse (on customer's side): 16 A, slow-blow
Protection class, control cabinet and operating panel: IP 54
Max. heat dissipation to environment: 1200 W
Sound pressure level approx.
measured at a distance of 1 m from the front, 1.6 m high: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1 K
Temperature gradient
(according to IEC 60068-3-5)
Temperature change rate
Heating: 0.6 K/min
Cooling: 0.3 K/min
Heat compensation at +20 °C to +50 °C: 200 W
Data for climate tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5 °C
Humidity range: 10 to 98 % RH
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.3 K
Temperature deviation spatially: ± 0.5 to ± 1 K
Humidity deviation over time: +1 to +3 % RH
Refrigerant: R-404A
Weight: 610 kg
For your security as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers will be subjected to a test run, which will be monitored with calibrated equipment.
Ijdpfx Ageziywrj Aotn
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Vötsch Temperature Test Chamber VTS³ 7018-5, 190 liters, -70°C to +180°C
VötschTemperaturprüfschrank VTS³ 7018-5
Call
Condition: used, Vötsch
Type: VTS³ 7018-5
Temperature test cabinet, water-cooled
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 900 mm x Depth 1550 mm x Height 1850 mm
Temperature testing:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: Cooling 7.5 K/min
Test chamber volume: 190 liters
Rated voltage: 400V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
Itsdpfx Agszfg Ucs Aen
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Vötsch Temperature Chamber VT 7011 -70°C to +180°C 110 liters (5717)
VötschVT 7011
Call
Condition: used, Vötsch
Type: VT 7011
Heraeus Vötsch temperature control cabinet, water-cooled
Test chamber volume: 110 liters
Test chamber dimensions: Width 560 mm, Depth 350 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1030 mm, Height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temperature gradient: 1 to 3 K
Cooling rate: 3.2 K/min
Heating rate: 3.5 K/min
Refrigerant: R-404 A / R 23
Voltage: 1/N/PE AC 230V ±10%, 50Hz
Rated power: 1.8 kW
Rated current: 12 A
For your security as a buyer, please note the following:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
Iedpfx Agjzdtd Is Ajtn
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We are happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
H. Köhler HK 300 S Kesternich Corrosion Test Chamber | SO₂ Test Cabinet | DIN 50017 | 300 liters
KöhlerHK 300 S
Call
Condition: used, H. KÖHLER GmbH
Kesternich corrosion test equipment / SO₂ corrosion test system
H. KÖHLER HK 300 S
Corrosion test equipment according to DIN 50017 / DIN EN ISO 6988
For sale is a used corrosion test system
from the manufacturer H. Köhler GmbH.
The equipment is suitable for carrying out reproducible Kesternich or SO₂ corrosion tests
for metals, coatings, paints and components in the laboratory, development and quality assurance.
Technical data
Manufacturer: H. Köhler GmbH
Type: HK 300 S
Equipment type: Kesternich corrosion test equipment / corrosion test cabinet
Test standards: DIN 50017 / DIN EN ISO 6988 (DIN 50018)
Test chamber volume: approx. 300 liters
Temperature range: ambient temperature to approx. +55 °C
Humidity range: saturation operation possible
Test chamber heating: 1,000 W
Connected load: approx. 1,100 W
Power connection: 230 V / 50 Hz
Itodpfx Aozg U Tiog Aen
Compressed air consumption during ventilation: approx. 3 Nm³/h
Compressed air connection: 4.5 - 7.0 bar
Deionized water connection: 2.5 - 4.0 bar
Spray pressure: 0.7 - 1.5 bar
Dimensions (without brine tank):
Height: approx. 1,750 mm
Width: approx. 1,200 mm
Depth: approx. 600 mm
Weight: approx. 100 kg
Control
HK PC102 microprocessor control
LCD display
Programmable test programs
Temperature control
Test sequences according to company standards and DIN 50017
Equipment
Stainless steel test chamber
Large glass door with seal
Temperature display
Test chamber thermometer
Manometer
Ventilation system
Gas dosing device
Compressed air connection
Deionized water connection
Exhaust air connection
Operating manual
Maintenance documentation
EC Declaration of Conformity
Application areas
Corrosion testing
Kesternich test
SO₂ corrosion test
Coating test
Paint test
Material test
Automotive industry
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures.
Scope of delivery
H. Köhler HK 300 S corrosion test equipment
Operating manual
EC Declaration of Conformity
Maintenance documentation
Documentation
Accessories as shown in the pictures
The machines, tools and other items visible in the pictures,
which are not explicitly described, are not included in the scope of delivery.
Shipping or freight transport possible.
Subject to change, errors and prior sale.
We would be happy to answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
RS Simulators ST2K 1000/55 Temperature Shock Chamber -70°C to +180°C 580 liters
RS-SimulatorenRS ST2K 1000/55
Call
Condition: used, RS Simulators
RS Simulators ST2K 1000 / 55
Itedpfx Aey H Igfeg Aon
Temperature Shock Chamber
Water-cooled
The unit was regularly serviced and maintained by the manufacturer until it was decommissioned.
For sale is a high-performance temperature shock test chamber, type ST2K 1000 / 55.
The unit is ideal for standard-compliant thermal shock tests in accordance with DIN EN 60068-3-5, as well as for demanding material and component tests.
With its two separate temperature chambers and automatic horizontal test basket transfer, this unit offers the perfect solution for reliability tests in industry, automotive, research and quality assurance.
Key technical data:
Temperature ranges
Upper test chamber (hot chamber): +40 °C to +180 °C
Time deviation: ±0.8 K (according to DIN 50011, empty chamber)
Lower test chamber (cold chamber): –70 °C to +100 °C
Time deviation: ±0.8 K (according to DIN 50011, empty chamber)
Test basket transfer:
Horizontal movement (automated)
Fast changeover for temperature shock tests
Test chamber / usable volume (Type ST2K 1000)
Volume: approx. 580 liters
Internal dimensions: Width approx. 1070 mm, Height approx. 680 mm, Depth approx. 800 mm
Max. load: approx. 150 kg
Power supply:
Total power: max. 33 kVA
Current consumption: max. 65 A
Mains connection: 3 × 400 V / N / PE / 50 Hz
Main power cable: 5 × 25 mm²
Water & compressed air connections
Cooling water inlet: G 1", approx. 3 bar, max. 10 bar / max. 15 °C
Cooling water requirement: max. 3.2 m³/h
Cooling water return: non-pressurized, max. 22 °C
Condensate drains: multiple (non-pressurized)
Compressed air connection: quick-release coupling NW 7.2 (G 1/4"), min. 4 bar, max. 10.5 bar
Dimensions & Weight:
External dimensions:
Width: approx. 2800 mm
Height: approx. 2400 mm
Depth: approx. 2200 mm
Weight: approx. 2800 kg
Equipment
Horizontal basket movement
C-rails in the test chamber
Large test basket (>1000 mm width)
Full-fledged changeover cabinet
Observation window
Internal lighting
SE-604 control unit
Program operation and data recording possible
RS232 interface
Other technical data
Sound level: approx. 67 dB(A) at 1 m distance (free field)
Refrigerant:
R449A: approx. 8.0 kg (GWP 1397)
R23: approx. 2.5 kg (GWP 14800)
Permissible operating environment:
Temperature: +12 °C to +30 °C
Humidity: 25 %–75 % RH
Operating hours
approx. 4,500 hours
For your security as a buyer, please note the following information!
The following points will be carried out on our offered units in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerants
3. Leak test with certificate
4. Documented test run after successful inspection
Condition: used
Scope of supply: (see pictures)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions by telephone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss Temperature Test Chamber WT3-600/70/5, 600 liters, -70°C to +180°C
WeissWT3- 600/70/5
Call
Condition: used, Weiss
Type: WT3-600/70/5
Weiss temperature testing cabinet WT3-600/70/5
water-cooled version
with S!MCON / 32 control system and touch panel
Control panel "Touch Panel"
By simply touching the function symbols on the "Touch Panel" control panel, all control and operating commands can be activated.
Adjustable feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing cabinet is equipped with adjustable feet.
Feedthroughs
The testing cabinet is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Feedthroughs installed as standard:
R1: DN 125 mm
L1: DN 50 mm
Test chamber volume: approx. 600 liters
External dimensions including hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions excluding hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Data for temperature tests:
Temperature range: -70 °C to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
Heating: 7.5 K/min
Cooling: 7.5 K/min
Maximum heat compensation: 2500 W
Iodpfx Agoy Nibpj Aetn
Data for operation:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: approx. 23 A
Rated power: approx. 13 kW
On-site fuse protection: 16 A slow-blow
Sound pressure level:
Measured at a distance of 1 m in front / 1 m height: approx. 58 dB(A)
Refrigerant:
R-404A / R23
Weight: approx. 620 kg
For your safety as a buyer, here is the following information:
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,614 km
Feutron TPK 3403/125 temperature test chamber -40 to +100°C temperature test cabinet
FeutronTPK 3403/125
Call
Condition: good (used), Feutron Temperature Testing Chamber -40 to +100°C
The Feutron TPK 3403/125, thanks to its robust design, is a reliable workhorse for standardized temperature tests.
The main application areas for this model are:
1. Electronics and Component Testing
This is the most common application. It involves testing how components react to extreme temperatures:
Functional testing: Does the circuit board still function flawlessly at -40 °C or +150 °C?
Burn-in tests: Artificial aging of components through continuous operation at high temperatures to provoke early failures.
2. Material Testing
Investigation of physical changes in materials:
Brittleness: Do plastics or rubber seals become brittle in the cold?
Deformation: Do composite materials warp in the heat?
Storage tests: How stable do chemical substances or adhesives remain over long periods at a constant temperature?
3. Quality Assurance (QA)
Sample testing: Tests carried out during production to ensure that the production process meets the specified temperature ranges.
Itsdoy Nynaspfx Ag Ajn
Standard testing: Conducting tests according to common industry standards (e.g., DIN EN 60068), which prescribe specific temperature profiles.
4. Research & Development
Prototyping: Testing new housing designs or materials under controlled thermal conditions before mass production.
Manufacturer: Feutron
Type: TPK 3403/125
Temperature range: -40 to +100°C
Refrigeration unit: Air-cooled condenser
Temperature stability: approx. ±0.1 to ±0.5 K
Usable volume: approx. 125 liters
Refrigerant: R22
Operating overpressure: 23 bar
Power connection: 220/280V-3-50Hz
Supply line fuse: 25 A
Protection class: IP 20
Weight: 480 kg
"Everything from a single source: We would be happy to offer you suitable bank financing for your project."
More items – new and used – can be found in our shop!
International shipping costs upon request!
Success:
Your message has been sent.
Listing
Borken
7,614 km
Heraeus Vötsch HC 4055 Climate Test Chamber 180°C Temperature Test Cabinet 550 l Oven KK04
HeraeusHC 4055
Call
Condition: good (used), Heraeus Vötsch HC 4055 Temperature Testing Chamber
Manufacturer: Heraeus Vötsch
Type: HC 44055
Temperature chamber
Temperature range: +180°C
Rated voltage: 380V, +/-10%, 3/N, 50Hz
Rated current: 13.5 A
Rated power: 9 kW
Housing dimensions: W 1065 x D 1560 x H 1890 (mm)
Observation window: Width x Height 350 x 640 mm
Test chamber: (L x D x H) approx. 800 x 795 x 855 mm
Test chamber volume: 550 l
Chamber is air-cooled
Caution:
Chamber can only be operated as an oven.
Refrigeration circuit is empty and deactivated.
Climate control system is deactivated.
Disconnected contactors:
03K2 Compressor
03K5 Condenser fan
15K6 Panel heater
Semiconductor relay 21V4 Humidifier.
Isdpfxsuuilve Ag Astn
Weight approx. 550 kg
You can find more new and used items in our shop!
International shipping costs upon request!
Success:
Your message has been sent.
Listing
Borken
7,614 km
Weiss Temperature Test Chamber WT 11-18 KWP 500/40, 500 liters, -40°C to +180°C
WeissKWP 500/40
Call
Year of construction: 1990, condition: good (used), Weiss temperature test chamber WT 11-18 KWP 500/40
Spring, summer, autumn, and winter – your products must be able to withstand different temperatures during manufacturing, transport, storage, and use. The temperature test chambers from Weiss Technik help you to test the influence of thermal conditions on the properties, function, and service life of your products.
Manufacturer: Weiss Technik
Type: KWP 500/40 - 180 DU
Designation: WT 11-18
Type: Temperature test chamber
Test chamber volume: 500 liters
Itsdpfeh Izh Iox Ag Aon
Temperature range: -40°C to +180°C
External dimensions: 110 cm wide, 173 cm deep, and 204 cm high
Internal dimensions: 80 cm wide, 85 cm deep, and 85 cm high
Pressure: 25 bar
Voltage: 380 V
Frequency: 50 Hz
kVA: 4.7
Refrigerant: R 502
Year of manufacture: 1990
Condition: used
Complete factory closure,
large selection of storage platforms, pallet racks, shelving systems, paternosters.
High-quality industrial machines, lathes, grinding machines, hand tools.
You can find more items – new and used – in our shop!
International shipping costs on request!
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss temperature chamber WT1-340/30, temperature range: -30°C to +180°C, 340 liters
WeissWT1-340/30
Call
Condition: used, Weiss
Type: WT1-340/30
Converted to R452a
Weiss temperature chamber, air-cooled
Temperature range: from -30°C to 180°C
Ijdpfxszd Rw Sj Ag Aetn
Temperature change rate, cooling: 1.6 K/min
Temperature change rate, heating: 2.1 K/min
Test chamber dimensions: Width 550 mm x Depth 750 mm x Height 800 mm
Housing dimensions: Width 800 mm x Depth 1500 mm x Height 1800 mm
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 4.9 kW, Rated current: 9 A
Refrigerant: R452a
Weight: 515 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Heraeus Vötsch temperature test chamber, temperature range -30 °C to +125 °C, 680 liters, model VLM
WeissVötsch VLM 3068/S
Call
Condition: used, Vötsch
Type: VLM 3068/S
Vötsch Temperature Test Chamber VLM 3068/S, Air-Cooled
(Top-loading test chambers for construction materials)
Control Panel
The control panel is mounted on a console on the temperature test chamber. All control and operating commands can be activated by simply touching the function symbols. The operating manual for the control panel is included.
Main Switch
Itjdpfx Aozgbmisg Asn
The main switch is located at the front of the temperature test chamber.
Air Handling Unit
The air handling unit is located in the test chamber and contains the components necessary for temperature control. In the air handling unit, the air is conditioned (cooled/heated) and circulated through the test chamber by the test chamber fan. The air is drawn in at the center of the side wall and re-enters the test chamber via the air deflectors on the long sides.
Feedthroughs
The temperature test chamber can optionally be equipped with feedthroughs. These allow cables and testing equipment to be placed in the test chamber. Feedthrough at the front 2 x 82 mm diameter, at the rear 1 x 85 mm diameter.
Internal Dimensions: Width 2000 mm, Depth 570 mm, Height 600 mm
External Dimensions: Width 3000 mm, Depth 870 mm, Height 1060 mm
Technical Data:
Data for Mechanical Load:
Max. load with test specimen
Test chamber floor
(evenly distributed over the area) 600 kg
Point load 50 kg
Data for Temperature Tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the useful space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for Operation:
Rated voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW Rated current 9 A
Fuse on customer side 16A slow-blow
Temperature Test Chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement Sound pressure level approx. 68 dB(A)
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Vötsch temperature testing chamber with spray device -30 to 80°C, 500 liters, VBT 03/500
VötschVBT 03/500
Call
Condition: used, Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in the stabilized state
according to IEC 60068-3-5, depending on the test chamber temperature
time-based ± 1 K
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the support grid.
Water level = 0 mm
The water level is at the upper edge of the support grid.
Data for spray device, standard
Number of spray nozzles 6
Spray volume per nozzle 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles 6
Ijdpfjzh D S Rjx Ag Aotn
Spray volume per nozzle 4.5 l/min
Additional flooding nozzles 2
Spray volume additional nozzle 6 l/min
Compressed air consumption approx. 3 m³/h
Data for water tank with preheating
Volume approx. 2000 l
Temperature range for preheating +5°C to +40°C
Temperature change duration
Cooling from +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Data for installation and operation:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Feedthroughs
1 feedthrough ∅ 50 mm installed on the left
Test chamber volume: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Rated voltage 3/N/PE AC 400V ± 10% 50Hz
Rated power approx. 26 kW
Rated current approx. 44.0 A (neutral conductor loaded)
Fuse 63 A gG, on customer's side
Weight approx. 890 kg net
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
CTS temperature test chamber T-40/600 -40...180°C 600 liters
CTST-40/600
Call
Condition: used, CTS
Type: T-40/600 /011232
CTS Temperature Test Chamber, Water-Cooled
Includes metal supports to increase the floor load capacity
Test chamber volume: 600 liters
Test chamber dimensions:
Height approx. 850 mm, Width approx. 850 mm, Depth approx. 830 mm
External dimensions:
Height approx. 1900 mm, Width approx. 1050 mm, Depth approx. 1850 mm
Temperature operating range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K over time
Heating rate: 2.5 K/min
Cooling rate: 3 K/min
Itodpfszh Htwjx Ag Asn
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
Rated power: approx. 5.5 kW
Rated current: approx. 8.5 A
Refrigerant: R-404A
Weight: 550 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
CTS Temperature Test Chamber T-70/600/S Temperature -70°C to 180°C 600 liters
CTSTemperaturprüfschrank
Call
Condition: used, CTS
Type: T-70/600/S
Water-cooled temperature testing chamber
Refrigerant: Converted to R-452A
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for customer-specific test specimen control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
Itedpfszh D E Rsx Ag Aen
approx. 2500 W at +20°C
approx. 2500 W at +0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test specimen, without radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Rated current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R-452A / R23
Weight: 700 kg
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Trust Seal
Dealers certified through Used-Machines

Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss temperature shock test chamber 130 liters TS 130
WeissPrüfschrank
Call
Condition: used, Weiss
Itjdpfxszp D Dio Ag Ajn
Type: TS 130
Temperature shock test chamber, water-cooled
Specification:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber changeover: 10 sec.
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lift platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss temperature shock test chamber 130 liters TS 130
WeissPrüfschrank
Call
Condition: used, Weiss
Itedpfx Agjzp D Axo Aen
Type: TS 130
Weiss Temperature Shock Test Chamber, Air-Cooled
(Compressor has been replaced!)
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with swivel arm): without… approx. 1820 mm, with… approx. 1915 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lift basket (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. circuit breaker rating: 35 A (32 A CEE plug)
Sound pressure level, 1 m in front of the unit: approx. 65 dB(A)
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Weiss temperature shock test chamber 130 liters TS 130 *
WeissPrüfschrank
Call
Condition: used, Weiss
Type: TS 130
Weiss Temperature Shock Testing Chamber, Air-Cooled
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber changeover time: 10 seconds
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lift basket (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on test chamber floor: max. 20 kg
Cooling water pressure: min. 2 … max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the unit: approx. 65 dB(A)
Refrigeration cascade: water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by telephone.
Itedpfxszp D A Ee Ag Ajn
Success:
Your message has been sent.
Listing
Borken
7,623 km
Vötsch VC³ 7018 climate test chamber / temperature chamber -70°C to +180°C, humidity, 190 liters
VötschVC³ 7018
Call
Condition: used, Vötsch
Climate testing chamber / Temperature testing chamber
Vötsch VC³ 7018 Climate testing chamber
Temperature and climate testing chamber, air-cooled
For sale is a used climate testing chamber from Vötsch Industrietechnik GmbH.
The testing chamber is suitable for temperature and climate testing, environmental simulation, material testing, quality assurance, as well as development and stress tests.
Itsdszm Ni Eepfx Ag Asn
Technical data
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 7018
Device type: Climate testing chamber / Temperature testing chamber
Test chamber volume: approx. 190 liters
Dimensions (approx.): Width: 870 mm, Depth: 1,550 mm, Height: 1,800 mm
Test chamber dimensions: Width: 580 mm, Depth: 450 mm, Height: 750 mm
Weight: approx. 460 kg
Temperature range: -70 °C to +180 °C
Temperature change rate (heating): approx. 4 K/min
Temperature change rate (cooling): approx. 3 K/min
Max. heat compensation: approx. 1,500 W
Temperature deviation (time-related): ± 0.1 to ± 0.3 K
Climate range (temperature): +10 °C to +95 °C
Humidity range: 10 to 98 % RH
Refrigerant 1: R404A
Refrigerant quantity: 2.5 kg
ND max.: 22.5 bar g
HD max.: 25 bar g
Refrigerant 2: R23
Refrigerant quantity: 0.75 kg
ND max.: 22.5 bar g
HD max.: 25 bar g
Mains connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated power: 4.9 kW
Rated current: 16 A
Equipment
Touch panel control
Programmable controller
Stainless steel interior
Temperature and humidity control
LAN/Ethernet interface
Viewing window with internal lighting
Documentation / Operating manual
Test reports
Accessories as shown in the pictures
Application areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Workshop-checked
Moisture absorber replaced
Optical condition as shown in the pictures
Scope of delivery
1x Vötsch VC³ 7018 climate testing chamber
Documentation / Operating manual
Test reports
Accessories as shown in the pictures
Important note:
For the safety of our customers, the following work will be carried out on the offered climate chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. Documented test run after successful inspection
The table shown in the photos, as well as any other items not explicitly mentioned, are not included in the sale.
Shipping or freight forwarding possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by telephone.
We make it easier for you to find: "temperature cabinet 990 liters"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time




























































































































































































