Systec VX-100 autoclaveSystec
VX-100
Systec VX-100 autoclave
Systec
VX-100
fixed price plus VAT
€14,000
Year of construction
2014
Condition
Used
Location
Żychlin 

Show images
Show map
Machine data
- Machine type:
- Systec VX-100 autoclave
- Manufacturer:
- Systec
- Model:
- VX-100
- Year of construction:
- 2014
- Condition:
- excellent (used)
Price & Location
fixed price plus VAT
€14,000
- Location:
- ul Narutowicza 44-10, 99-320 Żychlin, Polska

Call
Details about the offer
- Listing ID:
- A208-65352
- Update:
- 09.01.2026
Description
Autoclave Systec VX-100. The device has only undergone testing phases.
Fully automatic, microprocessor-controlled system covering 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid media
12 Cleaning
• Integrated separate steam generator (no heating elements in the sterilization chamber)
• Innovative safety ring closure system with lip seal
• Steam temperature and pressure up to 140°C / 4 bar absolute pressure, extendable to 150°C / 5 bar absolute pressure
• Thermal lock: door locking system controlled by pressure and media temperature according to pressure vessel regulations
• Flexible PT-100 temperature sensor for reference vessel
• Sterilization time controlled by media temperature
• Electronic pressure transducer for monitoring pressure and temperature
• “Autofill” – automatic dosing of demineralized water for steam generation
• Special waste destruction program with pulsed heating for better ventilation of waste bags
• Timer start / programmable delayed start
• Outlet steam condensation, water-cooled, thermostatically controlled
• Common manifold connection for all outputs
• Drain valve
• Base plate for tanks, baskets, etc.
• Validation port
• RS 232 interface for external data transfer
• Prepared for subsequent printer installation
• Prepared for subsequent fast cooling installation
• Prepared for subsequent vacuum system installation
• Prepared for subsequent drying installation
• Safety switch for low water level
• Safety switch for overtemperature
Gedpfx Aaex R Emke Iebg
Options installed in the autoclave:
Autoclave: VX-100 (Y-1100), ch+w, w, p, s, K, SAPL
ch – cooling
water cooling – ch+w
vacuum – p
drying – s
compressor – k
SAPL – system.
The listing was translated automatically. Translation errors are possible.
Fully automatic, microprocessor-controlled system covering 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid media
12 Cleaning
• Integrated separate steam generator (no heating elements in the sterilization chamber)
• Innovative safety ring closure system with lip seal
• Steam temperature and pressure up to 140°C / 4 bar absolute pressure, extendable to 150°C / 5 bar absolute pressure
• Thermal lock: door locking system controlled by pressure and media temperature according to pressure vessel regulations
• Flexible PT-100 temperature sensor for reference vessel
• Sterilization time controlled by media temperature
• Electronic pressure transducer for monitoring pressure and temperature
• “Autofill” – automatic dosing of demineralized water for steam generation
• Special waste destruction program with pulsed heating for better ventilation of waste bags
• Timer start / programmable delayed start
• Outlet steam condensation, water-cooled, thermostatically controlled
• Common manifold connection for all outputs
• Drain valve
• Base plate for tanks, baskets, etc.
• Validation port
• RS 232 interface for external data transfer
• Prepared for subsequent printer installation
• Prepared for subsequent fast cooling installation
• Prepared for subsequent vacuum system installation
• Prepared for subsequent drying installation
• Safety switch for low water level
• Safety switch for overtemperature
Gedpfx Aaex R Emke Iebg
Options installed in the autoclave:
Autoclave: VX-100 (Y-1100), ch+w, w, p, s, K, SAPL
ch – cooling
water cooling – ch+w
vacuum – p
drying – s
compressor – k
SAPL – system.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2019
Send inquiry
Telephone & Fax
+48 793 1... show
Your listing has been deleted successfully
An error has occurred