Used Weiss Walk-In Climate Chamber for sale (18,823)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Climate test chamber 350 liters with humidity control
CTSC -40/350 -40°C /+180°C
Call
Condition: excellent (used), CTS
Type: C-40/350
Air-cooled Climate Test Chamber
For sale is a professional CTS climate test chamber, model C-40/350. This device is designed for demanding environmental simulations in industrial applications and is ideal for material testing, electronics, automotive, aerospace, and research.
Temperature Testing:
- Temperature range: -40°C to +180°C
- Temperature deviation: ≤ ±0.3 K over time
- Temperature change rate according to IEC 60068-3-5:
- Heating: 3.5 K/min
- Cooling: 4 K/min
- Heat compensation:
- Approx. 3500 W at +20°C
- Approx. 2000 W at -20°C
Climatic Testing:
- Temperature range: +10°C to +90°C
- Humidity range: 10% to 95% relative humidity
- Dew point range: +5°C to +78°C
- Temperature deviation: ≤ 1.0 K over time
- Humidity deviation: ≤ ±3.0% r.h. over time
Technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without heat compensation, and without additional accessories. Options may influence performance data.
Technical Specification:
- Refrigeration unit: Air-cooled, low-noise, fully hermetic, infinitely variable performance adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
- Test chamber floor load: 150 kg/m²
- Shelf: Stainless steel, support surface 620 x 600 mm
- Maximum load per shelf: 35 kg
- Total load with maximum number of shelves: 100 kg
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numeric entry of setpoints
- Plain-text error messages
- RS 232 interface
- Ethernet interface
- Free switching channels for external test sample control
Dimensions:
- Test volume: 350 liters
- Internal dimensions: Height 750 mm × Width 650 mm × Depth 720 mm
Dcedpsx Ekupefx Aipjh
- External dimensions: Height 1800 mm × Width 920 mm × Depth 1670 mm
Operating Data:
- Electrical connection: 400V 3/N, 50 Hz
- Rated power: 7.1 kW
- Rated current: 11.5 A
- Protection class: IP 54
- Sound pressure level:
Listing
Arnschwang
8,130 km
3 climate smoke chambers including accessories
AUTOTHERM
Call
Condition: used, For sale or free of charge are three climate smoke chambers manufactured by AUTOTHERM, including accessories. These units are ideally suited for meat and food processing, particularly for cold smoking.
Technical Data / Features:
Chamber 1: approx. 8 racks (W approx. 2.10 m x D 5 m)
Chamber 2: approx. 10 racks (W approx. 2.10 m x D 6 m)
Chamber 3: approx. 12 racks (W approx. 2.10 m x D 7 m)
Cold smoke system with 2 smoke generators (Goliat, sawdust)
Temperature range up to approx. +22 °C (hot water heat exchanger)
Humidity control available
Cooling coil (R232, R404)
Some refrigerant compressors present
Dcodpfx Aisyw Hl Ijpsh
Construction:
Air ducts, wall cladding, and control cabinet made of V2A (stainless steel)
Condition:
Electronics/control currently non-functional
Control cabinet available
Condition as shown in the pictures
Additional equipment / accessories:
Smoking sticks (wood)
2 kettles
Cooking chamber (for 2 racks)
Cleaning machine (defective)
Freezer
Important notes:
Available free of charge
Dismantling and transport to be organized by the buyer
Inspection possible by appointment
Listing
Borken
7,623 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
Call
Condition: excellent (used), CTS CW‑60/5.5 – Water-Cooled Climate Test Chamber
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a mid-sized, walk-in or drive-in climate chamber designed for conducting temperature and humidity tests on multiple test specimens simultaneously.
Equipment Description
This climate test chamber allows you to assess the function or material properties of test objects under controlled temperature and humidity conditions. Efficient air circulation with a high re-circulation rate ensures excellent transfer to the test goods. The air handling system is located at the rear of the inner chamber. All of the aggregates are mounted in a separate frame behind the unit, providing easy access. The control system is housed in a separate switch cabinet, while the user interface is integrated into the cabinet door.
To dehumidify the test chamber, it is equipped with a self-regenerating compressed air dryer. Fresh air can be supplied by a blower to purge the chamber as required.
Technical Specifications:
Temperature Testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate (linear with test specimen and radiant heat, measured at supply air):
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
- Temperature range: +10 °C to +90 °C
- Humidity range: 10% to 95% relative humidity
(dew point range +5°C to +89 °C)
- Temperature deviation: ±0.5 K over time
- Humidity deviation: ±1 to ±3 % r.h. over time
Technical data based on ambient temperature of +25 °C, rated voltage 400 V, without test specimen, without radiant heat, and without additional equipment.
Dimensions:
Internal dimensions (test/useable space):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height 2300 mm, Width 1600 mm, Depth 1550 mm
External dimensions:
- Height 2800 mm, Width 2250 mm, Depth 5000 mm
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Rated power: 58.3 kW (incl. 5 sockets)
- Rated current: 86.0 A
- Protection category: IP 54
Technical Design:
- Refrigeration unit: water-cooled, low-noise, semi-hermetic, stepless power adjustment via electronic monitoring and control system
- Environmentally friendly refrigerants: R 23 / R 404 A
Notes:
- Inspection possible by appointment (46325 Borken)
Dedox Eabpspfx Aipjch
- Shipping by freight forwarding possible – costs & organization on request
- Scope of delivery: (see picture)
- (Subject to modifications and errors in technical data, all information provided without guarantee!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,623 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
Call
Condition: excellent (used), CTS CW-60/5.5 – Water-cooled Climate Test Chamber
The CW-60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in and drive-in climatic chamber designed for simultaneous temperature and humidity testing on multiple test specimens.
Device Description
The climate test chamber allows for functionality or material property testing of a test item under the influence of temperature and humidity. Efficient air circulation with a correspondingly high level of recirculating air volume ensures excellent transfer to the test item. The air treatment compartment is located at the rear of the test chamber. The aggregates are positioned behind the unit in a separate frame for easy access. The control system is integrated into a separate control cabinet. The control panel is mounted in the door of the control cabinet. For dehumidification, the test chamber is equipped with a self-regenerating compressed air dryer. The test chamber can also be purged with fresh air via an internal blower.
Technical Specifications:
Temperature Testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate, linear with specimen and heat radiation, measured in supply air:
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
- Temperature range: +10 °C to +90 °C
- Humidity range: 10% to 95% rH
- Dew point range: +5 °C to +89 °C
- Temperature deviation: ±0.5 K over time
- Humidity deviation: ±1 – ±3% rH over time
Technical data refer to an ambient temperature of +25 °C, nominal voltage 400 V, without test item, without external radiation and without additional devices.
Dimensions:
Dsdox Eaxbjpfx Aipsch
Internal dimensions (test space/usable volume):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height: 2,300 mm, Width: 1,600 mm, Depth: 1,550 mm
External dimensions: Height: 2,800 mm, Width: 2,250 mm, Depth: 5,000 mm
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Nominal power: 58.3 kW (incl. 5 sockets)
- Nominal current: 86.0 A
- Protection rating: IP 54
Technical Execution:
Refrigeration unit:
Water-cooled, low noise, semi-hermetic, infinitely variable capacity adjustment via electronic monitoring and control system, environmentally friendly refrigerants R 23 / R 404 A
Notes:
Inspection by appointment possible (46325 Borken)
Shipping by forwarding agent possible – Costs & organization upon request
Scope of delivery: (see photo)
(Subject to change and possible errors in the technical data; information provided without liability!)
For further questions, we are happy to assist you via telephone.
Listing
Borken
7,623 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
Call
Condition: excellent (used), CTS CW-60/5.5 – Water-cooled Climatic Test Chamber
The CW-60/5.5 by CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in or drive-in climate chamber for conducting temperature and humidity tests on multiple test specimens simultaneously.
Dedpfxox D Abpj Aipsch
Device Description
The climatic test cell enables testing of the functionality or material properties of a specimen under the influence of temperature and humidity. Optimized air circulation with a high recirculation rate ensures effective climate transfer to the test specimen. The air conditioning compartment is located at the rear of the interior chamber. The units are housed in a separate frame behind the main device and are easily accessible.
The control system is installed in a separate control cabinet, and the control panel is integrated into the cabinet door.
For dehumidification, the test cell features a self-regenerating compressed air dryer. Fresh air can be flushed into the test chamber using a fan.
Technical Specifications:
Temperature Tests:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate, linear with specimen and radiant heat, measured in supply air:
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Tests:
- Temperature range: +10 °C to +90 °C
- Humidity range: 10% to 95% r.H.
- Dew point range: +5 °C to +89 °C
- Temperature deviation: ±0.5 K over time
- Humidity deviation: ±1 to ±3% r.H. over time
The technical data refer to an ambient temperature of +25 °C, nominal voltage 400 V, without test specimen, no radiant heat, and without additional equipment.
Dimensions:
- Interior (Test chamber / usable space):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height: 2300 mm, Width: 1600 mm, Depth: 1550 mm
- External dimensions: Height: 2800 mm, Width: 2250 mm, Depth: 5000 mm
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Nominal power: 58.3 kW (incl. 5 sockets)
- Nominal current: 86.0 A
- Protection class: IP 54
Technical Design:
- Refrigeration unit: water-cooled, low-noise, semi-hermetic
- Infinitely variable capacity adjustment via electronic monitoring and control system
- Environmentally friendly refrigerants: R 23 / R 404 A
Additional Information:
- Inspection possible by arrangement (46325 Borken)
- Shipping by freight carrier is possible – costs & arrangements upon request
- Scope of delivery: (see picture)
- (Changes or errors in technical data reserved)
- For further questions, we are happy to answer your call.
Listing
Borken
7,623 km
Walk-in climate simulation cell
TIRAKB 127 TCZ 4022 S -2K -40 bis +140°C
Call
Condition: excellent (used), TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation chamber
System Structure:
The unit consists of the following main assemblies:
- Walk-in, insulated chamber
- Air handling room
- Humidification system
- Machinery room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
- Cooling rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
Dedjvx S Hhspfx Aipsch
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% RH (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% RH, measured in supply air
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% RH (without thermal test chamber load; with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (WxDxH): approx. 2260 x 4648 x 2260 mm
- External dimensions (WxDxH): approx. 2660 x 6460 x 2800 mm
- Clear door passage test chamber door (WxH): 2260 x 2260 mm
- Climate module KB 127 (WxDxH): 1700 x 800 x 1400 mm
- Control cabinet (WxDxH): 800 x 500 x 2000 mm
Design:
- Airflow: Supply air via perforated plate at the rear wall, ceiling area; exhaust air via perforated plate at the rear wall, floor area
- Temperature control: Direct cooling via evaporation of refrigerant in a finned heat exchanger; heating via electric resistance heater
- Dehumidification: Direct dehumidification via refrigerant evaporation in a heat exchanger
- Interior lining: Stainless steel
- Exterior cladding: Galvanized, plastic-coated steel sheet
- Floor: Stainless steel, floor load 15,000 N/m²
- Wheel load (contact area ≥4 cm²): 1,500 N/wheel
- Door: Double-leaf, stainless steel, externally coated with viewing window (WxH): 1000 x 1000 mm
- Test area lighting: 4 spotlights, 500 W each
- Insulation: Dual-layer insulation, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc): Bitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc): EDB 40
Color scheme:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidification unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10%, 3/PE N, 50Hz
- Rated power: 95 kW
- Rated current: 150 A
Listing
Borken
7,623 km
Walk-in temperature and humidity test chamber
CTS KlimaschrankCW+40/7/7 40–90°C
Call
Condition: excellent (used), CTS
Model: CTS CW+40/7/7
Walk-In Climate Chamber
CTS Walk-In Climate Chamber 7 m³
Temperature & Humidity Testing 40–90°C
Description:
For sale is a walk-in climate-temperature test cell, CTS CW+40/7/7, industrial design.
This system is used to simulate defined temperature and climate conditions for testing materials, assemblies, and technical systems under realistic environmental conditions. Temperature and humidity can be precisely controlled, and both constant and programmed test cycles are possible. High air circulation ensures uniform climate distribution throughout the entire test area. The walk-in construction enables testing of large components or complete systems.
Technical data:
Manufacturer: CTS – Clima Temperatur Systeme
Model: CW+40/7/7
Serial number: 113011
Year of manufacture: 06 / 2011
Design: Walk-in climate test cell
Test volume: 2 × 7 m³
Electrical data:
Power supply: 400 V / 3N / 50 Hz
Rated power: 29.6 kW
Rated current: 45.8 A
Climatic data:
Temperature range: +40 °C to +90 °C
Humidity range: 10 % to 90 % RH
Dew point range: +30 °C to +87 °C
Protection rating: IP44
Internal dimensions:
Width: 1400 mm, Depth: 1300 mm, Height: 2250 mm
Overall external dimensions:
Width: 3511 mm, Depth: 2765 mm, Height: approx. 2515 mm (overall)
Additional technical data:
Djdpfxoylmamj Aipsch
Sound pressure level: 56 dB(A)
Cooling: Water-cooled
Heating: Stainless steel heating elements
Internal chamber: Stainless steel
Exterior: Coated steel panels (RAL 9010)
Air circulation: Radial fan
Control: 32-bit controller with LCD
Interfaces: RS-232 / RS-485
Program and cycle mode available
Safety temperature limiter & emergency stop available
Refrigerant: R404A
Weight: approx. 2000 kg
Condition: used
Scope of delivery: (see image)
(Specifications subject to change and error!)
We are happy to answer further questions by phone.
Listing
Borken
7,614 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1998, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1998
TK 09
Dcodpfx Aouuin Rjipoh
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,614 km
Climate test chamber Temperature test
VötschVCS 7100
Call
Condition: good (used), Vötsch VCS 7100 Climatic Test Chamber -70°C to +180°C
Manufacturer: Vötsch
Type: VCS 7100
Temp. Range: -70°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
Height: 1980 mm
Width: 1350 mm
Depth: 2060 mm
Chamber:
Height: 900 mm
Width: 970 mm
Depth: 1400 mm
KK-05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Dodpfx Aouuix Njipjch
Listing
Borken
7,614 km
Climate test chamber Temperature test
Andreas SchmidVKT 3.000 /-40/+130
Call
Condition: good (used), Year of construction: 2005, Andreas Schmid Climatic Test Chamber -40°C to +130°C
Manufacturer: Andreas Schmid
Type: VKT 3.000 /-40/+130
Temp. Range: -40°C to +130°C
Program Controller: Stange SE - 502
Line Voltage: 400 V
Rated Current: 32 A
Refrigerant: R 404 A / R 23
Year of Manufacture: 2005
External Dimensions: W 1600 x D 800 x H 2430 mm
Dcodeuuibkjpfx Aipsh
TK-16
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
7,614 km
Climate test chamber climate chamber
Weiss Umwelttechnik GmbHWK-1000/70
Call
Year of construction: 2004, operating hours: 34,304 h, condition: excellent (used), Weiss climatic test chamber -70 to +180 °C
Dsdpsph U Ayefx Aipjch
Manufacturer: Weiss Umwelttechnik GmbH
Type: Climatic chamber WK-1000/70
Test chamber volume: 990 liters
Temp. range: -70 to +180 °C
Humidity: 10 to 98 %
Mains voltage: 400 V 3/N 50 Hz
Rated current: 29 A
Nominal output: 13.8 kW
Refrigerant: R 404A
Control system
SIMCON/32 microprocessor-controlled control and monitoring system
- 32 bit technology
- Graphic display of setpoint and actual value
- Digital setpoint and actual value display of temperature and % relative humidity
- digital input for temperature in °C and humidity in % rel. humidity
- Integrated programmer
- program memory
- Manual and automatic operation
- Fault diagnosis system
Operating hours: 34303.8 h
Year of construction: 2004
Test area dimensions:
Height: 950 mm
Width: 1100 mm
Depth: 950 mm
External dimensions:
Width: 1400 mm
Depth: 1900 mm
Height: 1970 mm
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further articles - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
7,614 km
Climate test chamber with seat pulsator
WeissSD 1400/+20 DU
Call
Condition: good (used), Weiss Climatic Test Chamber with Seat Pulsator
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test Chamber:
Material: Stainless steel
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Capacity: 1440 liters
Dcsdpfx Aoxbgrgoipsh
Outer casing
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: Light gray (RAL 9002)
Double-leaf door: hinged on the left and right
Equipment:
Tubing in the floor and ceiling: 2 each, NW 100 mm, for installing the pulsator tables
Tubing in the the side walls: 1 each, left and right, 100 mm
Cooling unit: Air-cooled
Control: Digital measurement and control system DMR
Basic control panel: Integrated into the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance data:
Temperature range without air conditioning: +20...+100 °C
Temperature stability without air conditioning: +0.2 ... t0.5 K (over time) depending on the range, in steady state
Temperature range with air conditioning: 20...+95 °C
Temperature stability with air conditioning: +0.2 ... +0.5 K (over time) depending on the range, in steady state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH depending on the range, in steady state
Temperature change rate measured in the exhaust without a test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. On average, between +20 and +100 °C
The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel construction for placing and attaching to the climatic test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for changing test specimens, 12 weights of 5 kg each
• 1 base frame in mild steel welded construction for attaching to the underside of the climatic test chamber. This frame is equipped with removable panels on all sides and has two hinged doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric discs with bearings and tachometer, 2 connecting rods, 2 ball bearings,
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for attaching the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for attaching the buttocks simulation
• 2 stainless steel 60° load rods (The connection to the test specimen is not included in our price, but can be offered subsequently upon precise specification.)
• 2 three-phase motors, 2 belt drives with tensioning devices,
• 1 pneumatic control unit with 2 manual valves, a filter-regulator unit, and a shut-off valve. 1 electrical control cabinet with 2 SEW frequency converters, hand switches, emergency stop button, 2 on/off switches, 2 speed indicators, 2 potentiometers for speed adjustment, 2 pre-selected load changers with zero position and shutdown.
Technical specifications:
Frequency: 100-1000 strokes/minute
Load: 2 x 45 g
Stroke: 0-40 mm
Load from above: 450 N each
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You can find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,614 km
Large-scale climate test chamber
VötschVCZ 04032
Call
Condition: good (used), Large-scale system for climate tests with S!MCON control
Design
The system consists of the following main components:
- Walk-in, insulated test room
- Air treatment room
- Machine unit
- Air conditioning system
- Control cabinet
Test room
The fixtures in the test room are made of corrosion-resistant material.
The test room can be illuminated, is walk-in, and has a condensate and cleaning drain.
Air treatment room
The air treatment room is located behind the air baffle in the insulated interior.
It contains the following components necessary for temperature control and is accessible via easily removable panels.
- Test room fans
- Heat exchangers
- Electric heaters
- Ventilation and exhaust system
- Temperature sensors
In the air treatment room, the air is tempered (cooled/heated), humidified and dehumidified, and circulated by fans.
The air is drawn in under the ceiling and expelled at floor level.
Sensors
The temperature and humidity sensors are located behind the air baffle in the air treatment room.
Machine Unit
The machine unit, consisting of refrigeration units, supplies the air treatment room with the required energy.
Climate System
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Direct temperature range: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5°C
Humidity fluctuation: +/- 3 to +/- 5% RH
Cooling water specifications
Dedpfjw U Sv Esx Aipsch
Connections
Inlet: 2 x 1 1/2" RH
Return: 2 x 1 1/2" RH
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10,000 N/m²
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m, Height 2.20 m, Depth 5 m
Climate chamber divided for transport at a specified location (approx. 2.50 m).
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items – new and used – in our shop!
International shipping costs on request!
Listing
Borken
7,614 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1997, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1997
TK 08
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Dcodpfx Aieuuiv Ijpoh
Listing
Borken
7,614 km
Climate test chamber Temperature test
VötschVCS 4100
Call
Condition: good (used), Vötsch VCS 4100 Climatic Test Chamber -40°C to +180°C
Manufacturer: Vötsch
Type: VCS 4100
Temp. Range: -40°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
Dcodpfx Ajuuiygsipsh
KK-07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
7,614 km
Climate test chamber Temperature test
Heraeus VötschHC 4055
Call
Condition: good (used), Heraeus Vötsch HC 4055 Temperature Test Chamber
Dcedpouuilvsfx Aipjh
Manufacturer: Heraeus Vötsch
Type: HC 44055
Temperature Chamber
Temperature Range: +180°C
Rated Voltage: 380V, +-10%, 3/N, 50Hz
Rated Current: 13.5 A
Rated Power: 9 kW
Housing Dimensions: W 1065 x D 1560 x H 1890 (mm)
Observation Window: Width x Height 350 x 640 mm
Test Chamber: (L x D x H) approx. 800 x 795 x 855 mm
Test Chamber Volume: 550 l
Cabinet is air-cooled
Caution
Cabinet can only be operated as an oven.
Refrigeration circuit empty and shut down.
Air conditioning system shut down.
Disconnected contactors:
03K2 Compressor
03K5 Condenser fan
15K6 Panel heater
Solid state relay 21V4 Humidifier.
Weight approx. 550 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
More items - new and used - can be found in our shop!
International shipping costs on request!
Listing
Borken
7,614 km
Climate test chamber Temperature test
VötschVTSR 7034/S
Call
Year of construction: 2002, condition: good (used), Vötsch VTSR 7034/S Climatic Test Chamber -70 to +180°C
Manufacturer: Vötsch
Dcodpeuuif Nsfx Aipsh
Type: VTSR 7034/S
Test Chamber Capacity: 335 liters
Climatic Test Chamber
Temp. Range: -70 to +180°C
Line Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Current: 22 A
Rated Power: 12.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Year of Manufacture: 2002
TK-11
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
7,614 km
Corrosion climate change test chamber
WEISSSC 1000/+20IU
Call
Condition: excellent (used), Weiss SC 1000/+20IU Corrosion Climatic Cycle Test Chamber
Weiss SC 1000/+20 JU Corrosion Climatic Cycle Test Chamber
The test system is a combination of a climatic test chamber with variable temperature and humidity and a corrosion test chamber with a salt spray test.
At-risk metallic components are tested for corrosion in a time-lapse manner according to the relevant standards.
Temperature Working Range
Temperature: +20 °C ... +60 °C
Temperature variation over time: +0.5 °C
Climatic Working Range
Temperature: +20 °C ... +60 °C
Temperature variation over time: +0.5 °C
Relative Humidity: 10...98 % RH
Temperature variation over time: 3...5 % RH
Dew point: +12 °C ... +59 °C
Salt spray test SS (ambient temperature range +5 °C ... +50 °C)
according to DIN 50 021 (salt spray via dual-fluid nozzle, 1.5 x 0.5 mV 80 cm h)
Control
Digital measurement and control system SIMCON/32*-Net with touchscreen control panel
Interfaces - Serial interface RS 232 C - Parallel printer interface
Operating modes adjustable via process controller:
- Temperature mode
- Air conditioning mode
- Salt spray test
- Direct spraying with saline solution
- Condensate load
- Flushing test chamber walls
- Drying/ventilating test chamber
Temperature sensor: Pt 100 resistance thermometer
Humidity sensor: Psychrome fresh measuring device TFT (with forced humidification)
Technical data SC 1000/+20 JU
Usable space dimensions
Height up to
sloped roof approx. 1000 mm
+ roof approx. 350 mm
Width approx. 1100 mm
Width between heaters approx. 1000 mm
Depth approx. 1000 mm
Test room door made of glass, hinged on the left
Height approx. 1350 mm
Width approx. 1000 mm
External dimensions including unit components and control cabinet
Height approx. 2100 mm
Width approx. 1450 mm
Width with touch control panel approx. 1700 mm
Depth approx. 2600 mm
Floor load max. 100 kg
Dcedpfx Aeph U Dhjipoh
Brine storage tank
approx. 200 l, with level monitoring separately next to/behind the unit
Height approx. 1000 mm
Width approx. 600 mm
Depth approx. 900 mm
Electrical connection: 400 V
Power rating: 13 kW
Weight: 1300 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items – new and used – in our shop!
International shipping costs on request!
Listing
Borken
7,623 km
Climate test chamber +20 to +130°C, 240 l
Weiss TechnikEmissionEvent VOC/240
Call
Condition: excellent (used), Weiss
Type: EmissionEvent VOC/240
Weiss Technik EmissionEvent VOC/240
Industrial Emission Test Chamber / VOC Test Chamber / Climatic Test Cabinet
Water-cooled
A professional emission test chamber is offered for sale
Weiss Technik EmissionEvent VOC/240 (Year of manufacture: 2018)
from an industrial laboratory and testing operation.
The device is designed for conducting standardized emission tests under precisely controlled temperature,
climatic, and process conditions, and is built for continuous use in laboratories, industrial settings, and quality assurance.
What does VOC mean / What does the device do?
VOC = Volatile Organic Compounds
The device measures and tests the outgassing (emissions) of materials under defined conditions.
It analyses which substances are released into the air by a given material. Typical applications include:
- Emission testing of plastics, components, materials
- Automotive interior material testing (odor / pollutants)
- Building products & furniture emission measurement
- Packaging, textiles, adhesives, paints
- Quality control and standard testing (e.g. ISO / VDA / DIN)
The test system generates precisely defined temperature, humidity, and air conditions.
Emissions are extracted from the test space using a carrier gas (e.g. nitrogen or air)
and can subsequently be analyzed using appropriate measuring equipment.
Device features / Equipment:
- Stainless steel emission test chamber (hermetically sealed)
- Temperature and climate control
- Carrier gas system for emission measurement
- Automatic process control with touch panel
- Programmable operation / continuous operation possible
- Sampling ports for VOC analysis
- Industrial-grade construction (suitable for laboratory and continuous operation)
Technical data for temperature testing:
- Temperature range: +20 to +130 °C
- Temporal temperature deviation at chamber center: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.1 to ±0.5 K
- Temperature change rate (according to IEC 60068-3-5):
Heating: 0.4 K/min
Cooling: 0.3 K/min
- Temperature change rate (average, with enhanced heating and cooling capacity):
Heating up to +65 °C: 1.5 K/min
Cooling from +65 °C to +20 °C: 1.3 K/min
Technical data for climate testing:
- Temperature range: +20 to +130 °C
- Dew point range: +5 to +60 °C
- Relative humidity range: 5 to 95% RH
- Temporal temperature deviation: 0.1 to 0.3 K
- Temporal humidity deviation: -3 to 3% RH
Dimensions EmissionEvent VOC/240
External dimensions (unit):
Width: approx. 1350 mm, Depth: approx. 2500 mm, Height: approx. 1985 (2190) mm
Internal dimensions (test space):
Emission test chamber: 200 l
Gross test chamber volume: 240 l
Net test chamber volume: 208 l
Max. test sample load: 80 kg
Internal dimensions VOC/240:
Width: approx. 600 mm, Depth: approx. 560 mm, Height: approx. 600 mm
Electrical:
Voltage: 3/N/PE AC 400 V ±10% / 50 Hz
Nominal power: 12.1 kW
Nominal current: 30 A
Dsdpfxeyhfg Do Aipsch
Protection class: IP54
Refrigerant:
R134a – 2.5 kg
Weight: approx. 1080 kg
Important information for you as the buyer:
The following procedures are carried out on the chambers we offer prior to sale:
1. Functional inspection and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Following successful inspection, a documented trial run is carried out
Condition: used
Scope of supply: (see picture)
(Technical data and specifications subject to change and errors!)
For further questions, feel free
Listing
Borken
7,623 km
Climate test chamber with humidity, 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Weiss
Model: WK3-340/40
Weiss Climate Test Chamber, Air-Cooled
Temperature Testing
Volume: 335 liters
Test Chamber Dimensions:
Internal Dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External Dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum Temperature: –42°C
Maximum Temperature: +180°C
Temperature Change Rate, Cooling: 4 K/min
Temperature Change Rate, Heating: 3.2 K/min
Temperature Deviation Over Time: ± 0.1 to ± 0.5 K
Temperature Uniformity Spatially: ± 0.5 to ±1.5 K
Climate Testing:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% RH
Dsdpsygv U Nsfx Aipsch
Temperature Deviation Over Time: ± 0.1 to ± 0.3 K
Temperature Uniformity Spatially: ± 0.5 to ± 1 K
Humidity Deviation Over Time: ± 1 to ± 3 % RH
Halogen Lamp: 2 x 24V, 50W
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Power: 4.1 kW, Rated Current: 14 A
Refrigerant: R-404A
Weight: approx. 515 kg
For your security as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications reserved!)
Further questions can be answered by phone.
Listing
Borken
7,623 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
Dcodpfsygvn Njx Aipoh
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Trust Seal
Dealers certified through Used-Machines

Listing
Borken
7,623 km
Climatic chamber
VötschVC³ 4100
Call
Condition: excellent (used), Vötsch Climate Test Chamber
We offer a Vötsch climate test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
External dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Feed-throughs: Ø 125 mm, Ø 50 mm
Specifications for temperature tests:
- Temperature range: -42°C to +180°C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature uniformity: ±0.5 to ±1.5 K
- Temperature change rates:
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
- Maximum heat compensation at +20°C: 4500 W
Specifications for climate tests:
Dcjdpsyguw Nsfx Aipjh
- Temperature range: +10°C to +95°C
- Dew point range: -3°C to +94°C
- Humidity range: 10 to 98% r.H.
- Temporal temperature deviation: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.5 to ±1.0 K
- Temporal humidity deviation: ±1 to ±3% r.H.
- Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
Important buyer information:
The following procedures are carried out on all our chambers prior to sale:
1. Functional checks and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
Listing
Borken
7,623 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Dodpfx Aieygut Ropsch
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,623 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Dcedjygutwepfx Aipeh
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
7,623 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Dcsdpfx Aieygur Tepeh
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)