Used High Temperature Chamber Furnace for sale (26,220)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
7,623 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS Climate Test Chamber T-70/600 Water-Cooled
Temperature Range: -70°C to +180°C
Rated Voltage: 400V 3/N PE 50 Hz
Rated Power: 6.7 kW
Rated Current: 10.2 A
Compressor: TFH2480Z/TFH2511Z, Refrigerant R23/R404A
Control System:
- Microprocessor-controlled regulation and monitoring system
- Simple, user-friendly terminal integrated into the door
- Digital display for set and actual temperature values
- Easy adjustment via +/- keys
- Digital input for temperature in °C
- PLC-compatible
- Up to 100 test programs possible
- RS 232 interface
- 2 free switching channels for user-side test specimen connections
Shelving:
Stainless steel, shelf area 820 x 710 mm
Load capacity per shelf max. 35 kg
Total load capacity with full shelf configuration 100 kg
Cooling Unit:
Water-cooled, low-noise, fully hermetic, stepless power adjustment via electronic monitoring and control system,
environmentally friendly refrigerants R404A/R23
Temperature Testing:
Temperature range -70°C to +180°C
Temperature deviation ±0.1 to 10.3 K over time
Lhjdoygultopfx Ammeh
Temperature change rate according to DIN 50 011, Part 12 measured at the center of the test chamber:
Heating: 2.5 K/min
Cooling: 2 K/min
Thermal radiation max. 1500 W at +20°C
Technical data refer to an ambient temperature of +25°C, rated voltage 400 V, without test specimen, without thermal radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x D x H)
External dimensions 1050 x 1850 x 1900 mm (W x D x H)
Operating Data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current 10.2 A
Protection class IP 22
Condensate drain non-pressurized, R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information reserved!)
Further questions can be answered by phone.
Listing
Borken
7,623 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), We are offering a Weiss temperature test chamber for sale.
Weiss Temperature Test Chamber with S!MCON / 32-controller, water-cooled
Control Unit: "Touchpanel"
All control and operation commands can be initiated by simply touching the function symbols on the "Touchpanel" control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for floor unevenness and to provide adequate ventilation for the machine section.
Cable Ports
Cable ports are installed on both the right and left sides of the test chamber. These allow measurement cables and test devices to be routed into the test space. Ports included as standard:
- R1: NW 125 mm
- L1: NW 50 mm
(The refrigerant has been converted to R-452A)
Test Chamber Volume: approx. 600 liters
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Temperature Test Data:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
Lhedpfxsyguh Ij Ammsh
Maximum thermal compensation: 2500 W
Operating Data:
- Test chamber lighting: Halogen bulb 2 x 24V, 50W
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated current: 15 A; Rated power: 7.8 kW
- Fuse (on-site): 16 A slow-blow
- Sound pressure level: approx. 58 dB(A) (measured 1 m in front, 1 m height)
- Refrigerant: R-452A
- Weight: 620 kg
Type: WT3-600/40
Important information for your safety as a buyer!
The following steps are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
Listing
Dortmund
7,674 km
Gas heated chamber furnace
VEIVEI-GB-KO
Call
Condition: new, TECHNICAL DATA
type: gas-heated drive-through chamber furnace
Lhsdpfx Amog Dgymsmeh
internal dimensions: (w x h x d): 2200 x 2350 x 3000 mm
number of control areas: 2
Max. loading weight: approx. 2,5 t
PLC: Siemens S7
Listing
Germany
7,694 km
Chamber tempering furnace
VEIVEI_KA_GB
Call
Condition: new, Gas heated furnace, make VEI
Lhsdpfocditnex Ammjh
type: KA_GB_TO
external dimensions (w x h x d): 3000 x 3700 x 2300 mm
interior dimensions (w x h x d): 1500 x 2200 x 1500 mm
temperature: 300 ° C
loading weight: max. 2500 kg
circulation fans: 2 x 4,0 kW = 8 kW
heating power: 120 kW
Listing
Germany
7,870 km
Chamber Furnace
Call
Condition: ready for operation (used), A floor chamber furnace of an unknown make is available. Internal volume: approx. 4m³, temperature range: 50°C-400°C, internal dimensions X/Y/Z: approx. 1800mm/1500mm/1800mm, machine dimensions X/Y/Z: approx. 2500mm/2500mm/2500mm. An on-site inspection is possible.
Lsdpfx Asxp Rbhommshh
Listing
Germany
7,870 km
Chamber Furnace
EnergoKSF 500
Call
Year of construction: 1992, condition: ready for operation (used), Gross combustion chamber: 800l, usable combustion chamber: 500l, combustion chamber dimensions X/Y/Z: 820mm/600mm/1015mm, connected load: 100kW, max. operating temperature: 1400°C, machine dimensions X/Y/Z: approx. 1450mm/1150mm/2100mm, weight: approx. 1500kg. Including fresh air blower and control cabinet with controller Jumo Imago 500. On site inspection is possible.
Lhodpoyfv N Rjfx Ammsh
Listing
Germany
7,870 km
Chamber Circulation Furnace
PadelthermKEU 4063/400
Call
Year of construction: 2005, condition: ready for operation (used), Usable space: approx. 4m³, max. temperature: 400°C. The furnace is located in the outdoor storage area. Documentation available. An on site inspection is possible.
Lhsdpfx Amoygw S Asmeh
Listing
Dortmund
7,674 km
El. heated chamber furnace
VEIKO_EB
Call
Condition: new, El. heated chamber furnace, make VEI
type: KO_EB
recirculation: horizontal airflow
max. furnace temperature : 650°C
internal dimensions (w x h x t): 800 x 800 x 1000 mm
heating power: 51 kW
fan power: 5,5 kW
connected load: 61 kVA
Ljdpfxsipvgio Ammshh
Listing
Borken
7,614 km
Sample station temperature chamber
OC Oerlikon Management AG (balzers)LTE 020
Call
Condition: good (used), BALZERS LTE 020 – Thermally Controlled Sample Preparation Station
✔ Use in: Coating technology, semiconductor processing, surface analysis, electron microscopy
• Digital display unit with 4 channels (B1–B4)
• Temperature display in °C
• Adjustable via SET / UP / DOWN
• Separate controls for mains and lamp
• Power supply: 220V
Note:
Lhodpfxjxl A Ede Ammeh
For detailed technical specifications and processing instructions, we strongly recommend consulting the original data sheets or contacting the manufacturer directly.
You can find more items – new and used – in our shop!
International shipping costs upon request!
Listing
Borken
7,623 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Ledpfx Amou H U Twemjhh
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature test chamber 600 liters
CTST-40/600 -40...180°C
Call
Condition: excellent (used), CTS
Type: T-40/600 /011232
CTS Temperature Test Chamber, Water-Cooled
Includes metal struts to increase the floor load-bearing capacity
Lhedjwfdniepfx Ammeh
Test chamber volume: 600 liters
Test chamber dimensions:
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth approx. 1850 mm
Temperature operating range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K over time
Heating rate: 2.5 K/min
Cooling rate: 3 K/min
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Rated power: approx. 5.5 kW
Rated current: approx. 8.5 A
Refrigerant: R-404A
Weight: 550 kg
For your safety, please note the following information!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature chamber 2000 liters
CTST-40/2000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Refrigeration unit:
air-cooled, low-noise, fully hermetic, infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door hinge left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per shelf 35 kg
Total load with max. grid load 100 kg
Test area lighting: 3x halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Lhodpfsup T Uqsx Ammjh
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature range: -40°C to +180°C
Nominal voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Nominal current: 17.2 A
Compressor: TFH2516Z
Pipe feed-through NW 50
Control panel
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, width 975, depth 2200 mm
External dimensions: Height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1 m from the front) < 55 dB(A)
Weight: approx. 1200 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Lhjdpfx Amoun Izcomjh
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Lhedpfx Amsun Rulemsh
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature test chamber, water-cooled
Performance data:
With temperature change rate of 25 K/min
Test chamber dimensions Height 750 mm Width 580 mm Depth 615 mm
Ljdpfetz Rqmsx Ammjhh
External dimensions Height 1775 mm Width 780 mm Depth 1895 mm
Temperature range -72°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5
Temperature homogeneity in space ± 0.5 to ± 2.0
Temperature change rate cooling 25 K/min
Temperature change rate heating 25 K/min
Heat compensation at -20 °C 8000 W
Heat compensation at +20 °C 8000 W
Test volume: 270 liters
2x lateral feed-through ∅ 125 cm
1x side feed-through ∅ 50 cm
Cabinet is water-cooled
Test room lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 26 KW
Rated current: 44 A
Refrigerant: R-452A and R-23
Weight: approx. 980 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber spraying device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in steady state
according to IEC 60068-3-5 dependent on the test chamber temperature
over time ± 1 K
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the insert grid
Water level = 0 mm
The water level is at the top edge of the insert grid
Data for standard spray device
Number of spray nozzles: 6
Spray volume per nozzle: 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles: 6
Spray volume per nozzle: 4.5 l/min
Additional flooding nozzles: 2
Spray volume of additional nozzle: 6 l/min
Compressed air consumption: approx. 3 m³/h
Data for water tank with pre-temperature control
Volume: approx. 2000 l
Temperature range for pre-temperature control +5°C to +40°C
Temperature change duration
Cooling of +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Installation and Operation Data:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Plug-ins
1 50 mm diameter plug installed on the left
Lhjdpfxewc Nvgs Ammsh
Test chamber capacity: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Nominal voltage 3/N/PE AC 400V ± 10% 50Hz
Nominal power approx. 26 kW
Nominal current approx. 44.0 A (neutral conductor loaded)
Fuse protection 63 A gG, on-site
Weight approx. 890 kg net
For your safety, please note the following information!
The following steps are carried out on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Chamber furnace with wire heating / 1300 °C
NaberthermN 2260/S 2.580 Liter
Call
Condition: used, Nabertherm
Nabertherm N 2260/S Chamber Furnace with Wire Heating up to 1300 °C
Technical Specifications – Nabertherm N 2260/S
Feature / Value
Model: Nabertherm N 2260/S
Maximum temperature: 1300 °C
Voltage / connection: 400 V, 3~ (three-phase current), PE (protective earth)
Heating power: 75 kW
Heating zones: 5-sided (sides, bottom, door, optionally ceiling)
Internal dimensions (firing chamber)
Lhedpfx Amsw Ec Egomsh
Dimension / Value
Width (w): 1,500 mm
Depth (d): 1,000 mm
Height (h): 1,720 mm
Floor load: 10 kg/dm²
Volume: approx. 2,580 litres
External dimensions (overall unit)
Dimension / Value
Length (L): 2,000 mm
Width (W): 2,250 mm
Height (H): 2,850 mm
Weight: approx. 3,100 kg
Condition: used
Scope of delivery: (see picture)
(Technical data and specifications subject to change and errors excepted!)
For further questions, we are happy to assist you by phone.
Listing
Borken
7,623 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Lhodpfxoun Rv Ns Ammeh
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber 1000 liters
CTST-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Temperature test chamber T-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type T -55/1000/Li
1) T means: temperature
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Lhjdpovba Rajfx Ammjh
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may affect the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature test chamber 600 liters
CTST-70/600/S -70°C bis 180°C
Call
Condition: excellent (used), CTS
Type: T-70/600/S
Water-cooled temperature test chamber
Control system:
- 32 bit controller
- LCD control panel
- Digital display of set and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R404A / R23
Weight: 600 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
Lhjdju U Ixmjpfx Ammeh
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
7,623 km
Temperature shock test chamber
EspecTSD-100
Call
Condition: good (used), Espec
Type: TSD-100
100 liters of usable space for larger test specimens up to 30 kg.
Complies with all current international standards.
Water-cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: 0 °C to -70 °C
Test chamber dimensions: 710 x 345 x 410 (W x H x D) in mm
External dimensions: 1100 x 1885 x 1965 (W x H x D) in mm
Water-cooled refrigeration unit
Program control via touch panel
Lodpsugl H Ssfx Ammehh
Automatic defrosting
Overtemperature protection
Operating hours counter
Mobile version
2 stainless steel test baskets
Cable gland Ø 100 mm
Refrigerant: R404A 1kg R23
Power supply: 400V 3Ph 50Hz
Max. Current consumption: 32A
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Used-Machines

Listing
Borken
7,623 km
Climatic chamber temperature and humidity
EspecPL-2KPH -40°C bis 180°C
Call
Condition: excellent (used), Espec
Model: PL-2KPH
ESPEC PL-2 KPH Climate Chambers, Air-Cooled
Temperature range: -40°C to +180°C
Humidity range: approx. 10 to 98% RH
Dependence on temperature range and humidity fluctuations:
± 2.5% RH over time, ± 3.0% RH
Internal dimensions (WxHxD): 500 × 750 × 600 mm
External dimensions (WxHxD): 910 × 1590 × 973 mm
Microprocessor control with 10 pre-set international test standards and 20 freely programmable memory slots,
Ledpfjx Iu I Ssx Ammshh
as well as built-in timer with programmable start/stop automation and error code display.
Programming via touch screen.
Alarm display (audible and visual).
Device protection against overtemperature:
Overtemperature protection with two switching contacts
Illumination of testing chamber
Operating hours counter
Test chamber volume: 225 liters
Net weight: 300 kg
Electrical connection: 400 V 3/N 50 Hz,
Plug: CEE 16 A, max. current: 11.0 A
Refrigerant: R404A
Scope of delivery: Espec climate test chamber
Buyer information for your security:
The following procedures are carried out in advance on the chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refilling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photos)
(Specifications and technical details subject to change and errors!)
If you have further questions, please feel free to contact us by phone.
Listing
Borken
7,623 km
Temperature shock chamber 200 liters
EspecTSA-202E-W -55°C bis 200°C
Call
Condition: excellent (used), Espec
Type: TSA-202E-W
Temperature Shock Chamber, Water-Cooled
Cold Chamber: -55°C to 0°C
Hot Chamber: +50°C to 200°C
System: Two-zone test with damper control
Temperature fluctuation ±0.5°C
Hot Chamber:
Temperature heating time: Ambient temperature (20°C) to +200°C within 15 minutes.
Cold Chamber:
Ljdpfxswc R A Io Ammohh
Temperature reduction time: Ambient temperature (20°C) (20°C) to -55°C within 35 minutes.
Temperature recovery: within 5 minutes.
Internal dimensions (W x H x D mm): 650 x 460 x 670
External dimensions (W x H x D mm): 1550 x 1900 x 1670
Approx. 200 liters
Power supply: 400 V AC 50Hz: 65 A
Refrigerant: R404A 5 kg R23 2.0 kg
Weight: Approx. 1200 kg
For your safety as a buyer, please note the following:
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
7,623 km
Temperature shock test chamber
WeissTS 130
Call
Condition: used, White
Type: TS 130
Temperature shock test chamber water-cooled
Specification:
Temperature range hot chamber +60°C … +220°C
Temperature range cold chamber -10°C … -80°C
Switch between hot and cold chambers 10 sec.
Temperature stability ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge) without....approx. 1820 mm with....approx. 1850 mm
Depth (without and with test chamber door) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket (test room) height 450 mm, width 500 mm, depth 600 mm
Volume 130 liters
Test room load max. 20 kg
Test room floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device approx. 65 dB(A)
Water-cooled cooling cascade
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current 26.0 A
Refrigerant R 404A / R23
Lhedpfxovwckho Ammsh
Weight: approx. 950 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Listing
Borken
7,623 km
Temperature test chamber 600 liters
CTST-70/600/S 70°C bis 180°C
Call
Condition: good (used), CTS
Type: T-70/600/S
Temperature test chamber water-cooled
Refrigerant: Converted to R-452A
Control:
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
Ljdpfsvitmdjx Ammohh
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R-452A / R23
Weight: 700 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "high temperature chamber furnace"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time




















































































































































































