Used Rps Cube Chiller for sale (1,336)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Success:
Your message has been sent.
Listing
Güglingen
7,922 km
Chiller
RPS CubeCAL013
Call
Condition: new, Year of construction: 2024, The Cube CAL series are air-cooled refrigeration systems for industrial use.
They are installed outdoors, but can also be installed indoors due to the non-flammable refrigerant R513A.
Tedpfx Ajr D Sanohmec
The Cube CAL 013 has an internal tank, an internal P3 pump and a coaxial evaporator. Operation can be guaranteed down to a process temperature of -10°C.
Cooling capacity at 7/12°C 35°C ambient temperature 7.9kW
Success:
Your message has been sent.
Listing
Derendingen
7,957 km
Chiller
Chiller YorkKomplettpaket 1chiller und 1Kühlaggregat
Call
Condition: used, Year of construction: 2019, Complete system for sale: 1 York chiller and one Jäggi cooling unit.
Todpfx Ahov Npgmemjc
Success:
Your message has been sent.
Listing
London
7,228 km
Chiller
5 pcs Star Refrigeration chiller R134a 8
Call
Condition: used, Year of construction: 2016, functionality: fully functional, Equipment: cooling unit, fridge, Five Star Refrigeration water-cooled chillers with six cooling towers
Industrial chilled-water packages by Star Refrigeration Ltd, Glasgow. Contract 100663, installed 2016. Five chillers in stock. Six cooling towers available with the set or separately. Price on request.
Tsdpfjzz Rfqsx Ahmsc
Each chiller is a packaged R134a plant on a steel skid: three semi-hermetic compressors, shell-and-tube chilled-water evaporator, oil separator, SMES control panel and gas detection.
Specification per chiller.
Manufacturer: Star Refrigeration, Thornliebank Industrial Estate, Glasgow G46 8JW
Refrigerant: R134a
Charge: 840 kg
Maximum allowable pressure: 18.0 barg high side / 17.2 barg low side
Year of installation: 2016
Supply: 400 V, 3 phase, 50 Hz
Control voltage: 110 V
Control panel: SMES
CE marked
Compressors
Three semi-hermetic compressors per machine, numbered 1–3, each with oil separator and terminal box. Refrigerant lines tagged R134a.
Evaporator
Stanref International shell-and-tube, model FEV3021/715, built October 2015, dry weight 2,200 kg.
Shell: R134a, 570 litres, design 17.2 bar.
Tubes: chilled water, 430 litres, design 10 bar.
Connections labelled CHILLED WATER.
Electrics
SMES cabinet with controller, start/stop and emergency stop.
Electronic Devices Ltd gas detector ED 811 (ATEX).
Schneider Electric isolator 415 V, 250 A, type SQB7200L.
Siemens motor 400/690 V, 50 Hz, IP55.
Cooling towers
Six towers in stock. Offered with the five chillers as a complete heat-rejection set, or as a separate lot.
Used industrial plant. Sale: one chiller, all five, towers only, or 5 chillers + 6 towers.
The five chillers come from one contract, so voltage, refrigerant, charge and layout match across the lot. Take a single machine for spare duty or take all five for a plant room. The six towers close the water-cooled circuit if you need heat rejection on the new site.
Success:
Your message has been sent.
Listing
Güglingen
7,922 km
Chiller
RPSFAR014
Call
Condition: new, Year of construction: 2024, type of cooling: air, CUBE Standard Series – Air-Cooled Chiller
Standard equipment: integrated pump and tank
Winter package: Operation down to -10°C ambient temperature
Safety: Gas sensor and ATEX fan inside the chiller unit
Cooling capacity: 9.57 kW at 7/12°C flow/return; 35°C ambient temperature
Propane small series available: 9.57 kW to 66 kW
Tjdpfot Twr Iex Ahmsc
Flexible adaptation: All units can be custom-configured to your process
Note: I am happy to provide you with a tailored quotation including installation,
Success:
Your message has been sent.
Listing
Wuppertal
7,675 km
Cooling unit cBoxX40 (KKT chillers)
KKT chillerscBoxX40
Call
Condition: like new (used), Year of construction: 2021, operating hours: 180 h, functionality: fully functional, cooling capacity: 29 kW (39.43 HP), type of input current: three-phase, type of cooling: air, ambient temperature (max.): 45 °C, ambient temperature (min.): 5 °C, input voltage: 400 V, pressure: 3 bar, temperature: 10 °C, volume flow: 4.5 m³/h, total width: 830 mm, total length: 1,240 mm, total height: 2,030 mm, noise level: 62 dB, empty load weight: 540 kg, input frequency: 50 Hz, Equipment: compressor, cooling unit, KKT cBoxX40 chiller, year of manufacture 2021, air-cooled cooling unit for frost-free indoor installation.
Cooling capacity 29 kW (at water supply temperature 10 °C, ambient temperature 35 °C). Refrigerant R410A, compressor with energy-efficient scroll technology. Condenser in a compact design with high fin efficiency and low refrigerant charge. Speed-controlled fan with EC-Blue technology according to ErP 2015, corrosion-resistant Owlet blades. Electronic expansion valve with high control accuracy. Evaporator as a plate heat exchanger in an asymmetrical design.
Tsdpjzzvgaofx Ahmsc
Water circuit: customer-specific piping with external connections, insulated stainless steel tank (1.4301) in an atmospherically open design, electronic level monitoring incl. low water/dry-run protection, temperature and pressure display in refrigerant supply and return, flow control for evaporator protection, multi-stage centrifugal pump.
Control cabinet: design according to DIN EN 60204 Part 1 and VDE 0113 Part 1, controller with plain text display (multilingual, including German, English, French), main switch, motor protection switch, transformer for 24 V DC control circuit, status display, protection class IP54, collective fault/warning message with potential-free contact, potential-free remote control, short-cycling protection, limit value monitoring min./max.
Technical data: flow rate 4.5 m³/h, free pump pressure 3.0 bar, air flow rate 9,350 m³/h, sound pressure level 62 dB(A), permissible ambient temperature +5 to +45 °C, tank volume 300 l, water connection Rp 1 1/2", operating voltage 400/3/50, dimensions (H×W×L) 2,030×830×1,240 mm, net weight 540 kg.
Additionally included: insulation of the refrigerant lines and the pump inside the housing, overpressure valve for standby operation, level kit (supplied loose) for height differences >500 mm between chiller and consumer, leveling feet (supplied loose) for vibration decoupling and height compensation up to 5° floor slope. Complies with the Ecodesign Directive (EU) 2015/1095 and (EU) 2016/2281.
Condition, history and handling: year of manufacture 2021, ordered 07/2021, delivery week 38/2021. The unit was operated in conjunction with a Sollich temperature control system, the production use of which amounted to approximately 180 operating hours; an operating hour counter is not available. Stored in Wuppertal since the end of 2024, inspection by appointment. Purchase value in 2021 according to offer: 9,800 € net. Sale from commercial to commercial, excluding warranty, technical data according to manufacturer's documents, errors and omissions excepted. This cooling unit is also available as part of a complete temperature control and mixing system (including Turbo temperature controller TE 1600 D and nut mixing unit NM 200 VA), see advertisement ID A22725782.
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerNational Lab - 67 kW
Call
Condition: used, Year of construction: 2008, cooling capacity: 67 kW (91.09 HP), type of input current: three-phase, type of cooling: air, overall weight: 690 kg, input voltage: 400 V, total width: 1,330 mm, total length: 2,330 mm, total height: 1,600 mm, Aircooled chiller National Lab 67 kW
Todpsxxtfbsfx Ahmec
Cooling capacity: 67 kW / 19,1 tons (12/7 — 35°C)
Year of manufacture: 2008
Type of refrigerant: R410A
Refrigerant circuit: 1 pcs.
Compressors: 2 pcs. Sanyo (scroll)
Number of fans: 3 pcs.
Dimensions: 2.30+0.25x1.33x1.60 m.
Weight: 690 kg.
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerCLIMAVENETA - 118.1 kW | With warranty
Call
Condition: good (used), Year of construction: 2022, functionality: fully functional, cooling capacity: 118.1 kW (160.57 HP), type of input current: three-phase, type of cooling: air, overall weight: 850 kg, input voltage: 400 V, total width: 1,200 mm, total length: 2,830 mm, total height: 1,980 mm, warranty duration: 6 months, AIRCOOLED CHILLER CLIMAVENETA NX2-G06 0122 118.1 KW
Cooling capacity: 118.1 kW / 33.58 tons (12/7 — 35°C)
Year of manufacture: 2022
Refrigerant circuit: 1 pcs.
Heat exchanger: Plate
Condenser: Microchannel, Aluminum
Compressors: 1 pcs. Bitzer GSD60235VLB4-2 (scroll) + 1 pcs. Bitzer GSD80295VLB4-2 (scroll)
Type of refrigerant: R454b
Number of fans: 2 pcs.
Dimensions: 2.83x1.2x1.98 m
Weight: 850 kg
Working hours: 2219/2220 h.
Condition: Used, tested, fully operational
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
Tsdpfsz Hkiqjx Ahmsc
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
Success:
Your message has been sent.
Listing
Güglingen
7,922 km
Chiller
RPSHAS 340
Call
Condition: like new (used), Year of construction: 2024, Air-cooled chiller HAS 340 with a cooling capacity of 273.75 kW at 7/12°C and 35°C ambient temperature. Refrigerant R454B GWP 467 A2L GAS. Shell-and-tube evaporator. Process temperatures down to -12°C. Compact design.
Tjdpfeu Atw Hsx Ahmsc
Success:
Your message has been sent.
Listing
Ensisheim
7,897 km
Cast iron clamping cube
Cube de bridage en fonte1000 x 600 x 800 mm
Call
Condition: used, Cast iron clamping cube 2 faces
Length: 1000 mm
Height: 600 mm
Depth: 800 mm
T-slots dimensions: 38 x 22 mm
Weight: approx 600 kg
Tedpfx Aezwxh Sjhmec
Success:
Your message has been sent.
Listing
Timișoara
8,865 km
Chiller
Chiller clint NEWClint CHA/K/ST 604-400
Call
Condition: as good as new (ex-display), Year of construction: 2014, functionality: fully functional, clint chiller for water cooling
Tsdpfx Ahjt Nhdtsmec
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerTRANE - 648 kW | With warranty
Call
Condition: good (used), Year of construction: 2009, functionality: fully functional, cooling capacity: 648 kW (881.03 HP), type of input current: three-phase, type of cooling: air, overall weight: 6,000 kg, input voltage: 400 V, total width: 2,300 mm, total length: 7,000 mm, total height: 2,600 mm, warranty duration: 6 months, AIRCOOLED CHILLER TRANE RTAC 185 648 KW
Cooling capacity: 648.0 kW / 184.25 tons (12/7 — 35°C)
Year of manufacture: 2009
Refrigerant circuit: 2 pcs.
Heat exchanger: Shell and tube
Condenser: Copper / Aluminum
Compressors: 1 pcs. Trane CHHP0N2TKG0N134A (screw) + 1 pcs. Trane CHHP0N1TKG0N112A (screw)
Type of refrigerant: R134a
Number of fans: 13 pcs.
Dimensions: 7x2.30x2.6 m
Tedpfez Dub Sex Ahmoc
Weight: 6000 kg
Working hours: 6001/6038 h.
Condition: Used, tested, fully operational
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
Success:
Your message has been sent.
Listing
Ensisheim
7,897 km
Cast iron clamping cube
Cube de bridage1290 x 920 x 510 mm
Call
Condition: good (used), Cast iron clamping cube
Length: 1290 mm
Width: 920 mm
Height: 510 mm
Tjdjzwxh Espfx Ahmec
T-slots dimensions: 42 x 25 mm
2 faces slotted
Weight: approx 1 T
Success:
Your message has been sent.
Listing
Güglingen
7,922 km
Chiller
RPSFAS096
Call
Condition: new, Year of construction: 2024, cooling capacity: 68 kW (92.45 HP), type of cooling: air, overall weight: 870 kg, temperature: 7 °C, The FAS series are air-cooled refrigeration units designed for industrial applications. Installation is carried out outdoors. The FAS 096 configuration includes a closed internal tank, a 3 bar pump, and Bitzer scroll compressors. The refrigerant used is R454B. The evaporator is a shell-and-tube type installed inside the internal tank. Cooling capacity at 12/7°C and 35°C ambient temperature is 68 kW.
Tsdpotw U Dqjfx Ahmsc
Success:
Your message has been sent.
Listing
Güglingen
7,922 km
Chiller
RPSFlexy FAS 064
Call
Condition: new, Year of construction: 2024, The FAS series are air-cooled refrigeration systems for industrial use.
Tjdpfx Ajr D R Ubohmec
They are installed outdoors.
The equipment of the FAS 064 is as follows:
closed internal tank as well as a 3 bar pump and scroll compressors, winter package down to -10°C,
The evaporator is a tube bundle installed in the internal tank.
The refrigerant used is R454B
Cooling capacity at 12/7°C and 35°C ambient temperature 49kW
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerTRANE - 648 kW | With warranty
Call
Condition: good (used), Year of construction: 2009, functionality: fully functional, cooling capacity: 648 kW (881.03 HP), type of input current: three-phase, type of cooling: air, overall weight: 6,000 kg, input voltage: 400 V, total width: 2,300 mm, total length: 7,000 mm, total height: 2,600 mm, warranty duration: 6 months, AIRCOOLED CHILLER TRANE RTAC 185 648 KW
Cooling capacity: 648.0 kW / 184.25 tons (12/7 — 35°C)
Tedez Ducpepfx Ahmjc
Year of manufacture: 2009
Refrigerant circuit: 2 pcs.
Heat exchanger: Shell and tube
Condenser: Copper / Aluminum
Compressors: 1 pcs. Trane CHHP0N2TKG0N134A (screw) + 1 pcs. Trane CHHP0N1TKG0N112A (screw)
Type of refrigerant: R134a
Number of fans: 13 pcs.
Dimensions: 7x2.30x2.6 m
Weight: 6000 kg
Working hours: 8934/6574 h.
Condition: Used, tested, fully operational
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerClimaveneta - 873 kW | With warranty
Call
Condition: good (used), Year of construction: 2009, functionality: fully functional, cooling capacity: 873 kW (1,186.95 HP), type of input current: three-phase, type of cooling: air, overall weight: 9,880 kg, input voltage: 400 V, total width: 2,260 mm, total length: 9,400 mm, total height: 2,430 mm, warranty duration: 6 months, Aircooled chiller Climaveneta FOCS-CA/SL 873 kW
Cooling capacity: 873 kW (12/7 — 35°C)
Year of manufacture: 2009
Heat exchanger: Shell and tube
Refrigerant circuit: 2 pcs.
Type of refrigerant: R134a
Compressors: 2 pcs. Bitzer (screw)
Number of fans: 12 pcs.
Dimensions: 9.40 x 2.26 x 2.43 m
Weight: 9 880 kg.
Working hours: 30717/30184 h.
Condition: Used, tested, fully operational
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
Tsdpfx Ahsy U U Hhomec
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
New Industrial ChillerCLIMAVENETA - 80 KW | With warranty
Call
Condition: new, Year of construction: 2017, functionality: fully functional, cooling capacity: 80 kW (108.77 HP), type of input current: three-phase, type of cooling: air, overall weight: 1,160 kg, input voltage: 400 V, total width: 1,110 mm, total length: 2,610 mm, total height: 1,930 mm, warranty duration: 12 months, AIRCOOLED CHILLER CLIMAVENETA NECS-C/HT 0302 80 KW
Cooling capacity: 80.0 kW / 22.75 tons (12/7 — 35°C)
Year of manufacture: 2017
Options: Hydraulic module.
Refrigerant circuit: 1 pcs.
Heat exchanger: Plate
Condenser: Copper / Aluminum
Compressors: 2 pcs. Copeland ZP182KCE-TFD-477 (scroll)
Type of refrigerant: R410A
Number of fans: 2 pcs. (centrifugal)
Hydraulic module: 1 pcs. water pump Ebara DWC-VI 500/3.0 IE3, expansion vessel.
Dimensions: 2.61x1.11x1.93 m
Weight: 1160 kg
Working hours: 0/0 h.
Condition: Outlet
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
Tjdpfx Ahsz Hkx Eomjc
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerCLIMAVENETA - 398.9 kW | With warranty
Call
Condition: good (used), Year of construction: 2022, functionality: fully functional, cooling capacity: 398.9 kW (542.35 HP), type of input current: three-phase, type of cooling: air, overall weight: 3,800 kg, input voltage: 400 V, total width: 2,260 mm, total length: 3,910 mm, total height: 2,560 mm, warranty duration: 6 months, AIRCOOLED CHILLER CLIMAVENETA NX2-G06 K 0424 398.9 KW
Cooling capacity: 398.9 kW / 113.42 tons (12/7 — 35°C)
Year of manufacture: 2022
Options: Hydraulic module.
Refrigerant circuit: 2 pcs.
Heat exchanger: Shell and tube
Condenser: Microchannel, Aluminum
Compressors: 2 pcs. Bitzer GSD80485VLB4-2 (scroll) + 2 pcs. Bitzer GSD80385VLB4-2 (scroll)
Type of refrigerant: R454B
Number of fans: 6 pcs. (Frequency inverter)
Hydraulic module: 1 pcs. water pump Lowara PLM112B14S2/355 E3, expansion vessel, buffer tank 700 l.
Dimensions: 3.91x2.26x2.56 m
Weight: 3800 kg
Working hours: 2260/2260/2259/2259 h.
Condition: Used, tested, fully operational
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Tjdpfx Asz Duahshmjc
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerSWEGON - 486 kW | With warranty
Call
Condition: good (used), Year of construction: 2015, functionality: fully functional, cooling capacity: 486 kW (660.78 HP), type of input current: three-phase, type of cooling: air, overall weight: 8,234 kg, input voltage: 400 V, total width: 2,500 mm, total length: 12,000 mm, total height: 2,300 mm, warranty duration: 6 months, Aircooled chiller SWEGON COBALT PRO SLN 58.2 FC 486 KW
Cooling capacity: 486 kW / 138.19 tons (12/7 — 35°C)
Year of manufacture: 2015
Options: Freecooling (370 kW)
Refrigerant circuit: 2 pcs.
Heat exchanger: Shell and tube
Condenser: Microchannel, Aluminum + Copper / Aluminum (Freecooling)
Compressors: 1 pcs. Bitzer CSH9563-160Y-40D (screw) + 1 pcs. Bitzer CSH8593-140Y-40D (screw)
Type of refrigerant: R1234ze
Number of fans: 20 pcs. (EC-fans)
Dimensions: 12x2.5x2.3 m.
Weight: 8234 kg.
Working hours: 13200/18920 h.
Condition: Used, tested, fully operational
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Todpfx Ahjzxc Huomsc
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerCLIMAVENETA - 642 kW | With warranty
Call
Condition: good (used), Year of construction: 2013, functionality: fully functional, cooling capacity: 642 kW (872.88 HP), type of input current: three-phase, type of cooling: air, overall weight: 9,590 kg, input voltage: 400 V, total width: 2,400 mm, total length: 7,000 mm, total height: 2,400 mm, warranty duration: 6 months, Aircooled chiller CLIMAVENETA FX FC NG SL T+ S 2702 642 KW
Cooling capacity: 642 kW / 182.5 tons (12/7 — 35°C)
Year of manufacture: 2013
Options: Hydraulic module. Freecooling. Heat exchanger for refrigerant subcooling with coolant.
Refrigerant circuit: 2 pcs.
Heat exchanger: Shell and tube
Condenser: Copper / Aluminum
Compressors: 2 pcs. Bitzer CSH8583-125CVY-40D (screw)
Type of refrigerant: R134A
Number of fans: 14 pcs.
Hydraulic module: 1 pcs. water pump Grundfoss NB65-125 (Freecooling) + 1 pcs. Grundfoss TY50-120 (Freecooling) +Grundfoss TY50-120 (Heat exchanger for refrigerant subcooling with coolant) 2 pcs.. Expansion vessel.
Tsdpfx Ajzxqc Rohmoc
Dimensions: 7x2.4x2.4 m.
Weight: 9590 kg.
Working hours: 4904/9813 h.
Condition: Used, tested, fully operational
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
Success:
Your message has been sent.
Listing
Güglingen
7,922 km
Chiller
RPSCAL 016
Call
Condition: like new (used), Year of construction: 2024, CAL 016 – Air-Cooled Chiller, Year of Manufacture 2024, As New
Cooling capacity: approx. 12.96 kW at 7/12°C supply/return, ambient temperature 35°C
Refrigerant: R513A (non-flammable gas)
Compressor: Scroll compressor
Hydraulics: integrated pump and thermal storage tank for easy installation
Process temperatures down to -10°C possible
Tedpfou Ar Nzsx Ahmec
Automatic bypass for flexible operation
Applications: reliable cooling in industrial processes, direct connection to existing hydraulic/cooling systems
Condition: As new, ready for immediate use
Trust Seal
Dealers certified through Used-Machines

Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerTRANE - 254.6 kW | With warranty
Call
Condition: good (used), Year of construction: 2016, functionality: fully functional, cooling capacity: 254.6 kW (346.16 HP), type of input current: three-phase, type of cooling: air, overall weight: 2,498 kg, input voltage: 400 V, total width: 2,300 mm, total length: 3,650 mm, total height: 2,350 mm, warranty duration: 6 months, Aircooled chiller TRANE CGAM090 254.6 KW
Cooling capacity: 254.6 kW / 72.39 tons (12/7 — 35°C)
Year of manufacture: 2016
Refrigerant circuit: 2 pcs.
Heat exchanger: Plate
Condenser: Copper / Aluminum
Compressors: 2 pcs. TRANE CSHN315K0BKM (scroll) + 2 pcs. TRANE CSHN250K0BKM (scroll)
Type of refrigerant: R410А
Number of fans: 8 pcs. (2 pcs. frequency inverter driven)
Tsdpfxszxny Hs Ahmoc
Dimensions: 3.65x2.3x2.35 m.
Weight: 2498 kg.
Working hours: 8866/8858/7036/7022 h.
Condition: Used, tested, fully operational
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerTRANE - 447.2 kW | With warranty
Call
Condition: good (used), Year of construction: 2006, functionality: fully functional, cooling capacity: 447.2 kW (608.02 HP), type of input current: three-phase, type of cooling: air, overall weight: 3,470 kg, input voltage: 400 V, total width: 2,260 mm, total length: 4,490 mm, total height: 2,200 mm, warranty duration: 6 months, Aircooled chiller TRANE RTAD125 447.2 KW
Cooling capacity: 447.2 kW / 127.16 tons (12/7 — 35°C)
Year of manufacture: 2006
Todpfozxp Apex Ahmsc
Refrigerant circuit: 2 pcs.
Heat exchanger: Shell and tube
Condenser: Copper / Aluminum
Compressors: 2 pcs. TRANE CHHP0M2TKF0N092A (screw)
Type of refrigerant: R134a
Number of fans: 6 pcs. (2 pcs. frequency inverter driven)
Dimensions: 4.49x2.26x2.2 m.
Weight: 3470 kg.
Working hours: 37650/49971 h.
Condition: Used, tested, fully operational
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
Success:
Your message has been sent.
Listing
Güglingen
7,922 km
Chiller
RPSFlexy FAS051
Call
Condition: new, Year of construction: 2024, functionality: fully functional, The FAS series stands out for its robust and compact design. The air-cooled refrigeration units are especially suitable for industrial applications, for example in the plastics or packaging industry. Installation is carried out outdoors. The equipment features of the FAS 051 are as follows: a closed internal tank, a 3 bar pump, and scroll compressors. The evaporator is a shell and tube heat exchanger integrated into the internal tank. The refrigerant used is R454B. Cooling capacity at 12/7°C and an ambient temperature of 35°C is 35 kW.
Todpfxjr D R Tho Ahmoc
Success:
Your message has been sent.
Listing
Łęczna
8,523 km
Chiller
Used Industrial ChillerStulz - 425 kW | With warranty
Call
Condition: good (used), Year of construction: 2008, functionality: fully functional, cooling capacity: 425 kW (577.84 HP), type of input current: three-phase, type of cooling: air, input voltage: 400 V, total width: 2,300 mm, total length: 3,900 mm, total height: 2,400 mm, warranty duration: 6 months, AIRCOOLED CHILLER STULZ CFO4202A 425 KW
Cooling capacity 425 kW / 120.8 tons (12/7 — 35°C)
Year of manufacture 2008
Options Freecooling
Refrigerant circuit 2 pcs.
Heat exchanger Plate
Condenser Copper / Aluminum
Type of refrigerant R410A
Compressors 3 pcs. Copeland ZP385KCE-TWD-522 / 3 pcs. Copeland ZP295KCE-TWD-522 (scroll)
Number of fans 8 pcs.
Dimensions 3.9х2.3х2.4 m.
Condition: Used, tested, fully operational
Tsdpfxjun Spqo Ahmoc
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
We make it easier for you to find: "rps cube chiller"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time