Used Rs-Simulatoren Thermal Shock Test Chamber for sale (20,373)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer you a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Air-Cooled
Dkedpfx Akjzp D Axsmeu
(Compressor has been replaced!)
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with swivel arm): without... approx. 1820 mm, with... approx. 1915 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Water-Cooled
Specification:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 sec.
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Dksdszp D Dijpfx Akmju
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Water-Cooled
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Switching time, hot/cold chamber: 10 s
Temperature stability: ±1 K
Djdpfjzp D A Sex Akmsku
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without... approx. 1820 mm, with... approx. 1850 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /18.7 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature shock test chamber 60 liters
WeissTS 60 -72…+220 °C
Call
Condition: excellent (used), Weiss Technik TS 60 Thermal Shock Test Chamber / 60 L, –71…+220 °C
Water-cooled
Item description:
Dkedpfjzii A Rjx Akmju
For sale is a Weiss Technik TS 60 Thermal Shock Test Chamber.
The chamber is ideally suited for rapid temperature cycling tests (e.g., per IEC, MIL-STD, JEDEC) and has been well maintained.
Volume & internal dimensions:
Test volume: 60 liters
Internal basket/test room dimensions (W × D × H): approx. 380 × 430 × 370 mm
External dimensions (W × D × H): 895 × 1970 × 1895 mm
Temperature ranges & cycling:
Hot chamber: +50 °C to +220 °C
Cold chamber: –72 °C to +70 °C
Transfer time (basket between both zones): < 10 seconds
Heating rate / speed up to 17 °C/min
Cooling rate / speed up to 3.7 °C/min
In single mode (cold zone only), heating rate: approx. 3.2 °C/min
Temperature deviation & uniformity:
Temporal deviation (temperature control over time): ± 0.3 to ± 1.0 °C
Load / permissible weight & lifting system:
Basket/lifting system load capacity: 20 kg maximum load
Transfer basket secured by safety grilles on all sides
Additional features & equipment:
Noise level: approx. 58 dB(A) in operation
Control: Touchscreen, RS-232 / USB / Ethernet interfaces
Electrical connection:
3/N/PE AC 400 V ±10% 50 Hz
Rated power: approx. 8.5 kW
Rated current: approx. 25 A
On-site protection: 32 A
Refrigerants: R-404A / R-23
Weight: 800 kg
Important safety information for buyers!
The following steps are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors reserved!)
For further questions, feel free to contact us by phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature test chamber
RS-SimulatorenTS 600/45 EX
Call
Condition: excellent (used), RS Simulators
We offer a test cabinet here.
Water-cooled
Temperature range: -40°C to +180°C
Test chamber dimensions: 850mm x 850mm x 800 mm (W x H x D)
External dimensions: 1100mm x 1850mm x 1500mm (W x H x D)
Power consumption: 13.5 A
Refrigerant: R404A
Connection voltage: 3x400V/N/PE 9A
Weight: approx. 750kg
Type: TS 600/45
Explosion-proof operation not tested
However, max. 160°C in this condition
Condition: used
Scope of delivery: (See image)
Dkedpezdn Stefx Akmou
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature test chamber
RS-SimulatorenTS 150/75
Call
Condition: excellent (used), RS Simulators
Here we offer a temperature test chamber.
Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Time deviation: ±1 K according to DIN 50011 in an empty test chamber
Average heating time: approx. 3 K/min (according to DIN 50011 Part 12)
Average cooling time: approx. 3 K/min (according to DIN 50011 Part 12)
Test chamber dimensions: Width 530 mm x Height 530 mm x Depth 530 mm
External dimensions: Width approx. 900 mm x Height approx. 1800 mm x Depth approx. 1400 mm
Total power: approx. 6 kVA
Current consumption: 12 A
Main fuse: 3 x 16 A, slow-blow
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 600 kg
Type: TS 150/75
Dkodpfx Aszd Sfqskmou
Refrigerant: R404A / R23
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have over the phone.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Climatic test chamber with humidity, 600 liters
RS-SimulatorenKSS600/75-10K -75°C bis +180°C
Call
Condition: excellent (used), RS-Simulators Climate Chamber KSS 600/75-10K
Device Data
Manufacturer: RS-Simulators Prüf- und Messtechnik GmbH
Type: KSS 600/75-10K
Dkedpfx Asy H Ib Aekmeu
Design: Climate test chamber / Environmental simulation chamber
Cooling: Water-cooled
Description
Used climate test chamber from RS-Simulators.
Suitable for temperature tests, climate tests, material and aging tests.
Application in industrial testing and measurement.
Technical Data
Temperature range: -75 °C to +180 °C
Temperature change: Heating/cooling approx. 10 K/min
Test chamber volume: approx. 600 liters
Dimensions
Internal (W x D x H): 840 x 840 x 840 mm
External (W x D x H): 1200 x 1600 x 1995 mm
Electrical Data
400 V / 3~ / N / PE
Current consumption: approx. 55 A
Refrigeration System
Refrigerant: R404A / R23
R404A: 6.0 kg
R23: 3.0 kg
Weight
approx. 1400 kg
Equipment
RS-Simulators control panel / operating panel
Program operation
Observation window
Temperature monitoring in the test chamber
Operating hour counter
Side feed-through
Robust industrial design
Scope of delivery
RS-Simulators climate chamber KSS 600/75-10K
Scope of delivery as shown in the pictures
Functional test
Refrigerant service
Leak test
Condition: Used.
Condition: See pictures.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to changes and prior sale.
If you have any questions, please do not hesitate to contact us.
Success:
Your message has been sent.
Listing
Borken
7,614 km
RS simulators Zwick / Roell temperature chamber for AllroundLine -40°C/+160°C
ZwickRoellTEE160/LN2 40S
Call
Condition: good (used), Zwick / Roell Temperature Chamber for AllroundLine
Type: TEE160/LN2 40S
The RS simulator model TEE160/LN2 40S is a specialized temperature chamber primarily designed for material testing in combination with ZwickRoell testing machines (especially the AllroundLine).
Flexible in Application
The innovative temperature chamber from ZwickRoell guarantees a flexible, customized testing system tailored to customer needs without compromise.
This ensures reliable test results, even in the future.
The safety door function guarantees operator protection in accordance with European safety standards.
The chamber door serves as a safety door with a locking mechanism.
Precise Temperature Control
The temperature chamber creates extremely homogeneous and precise conditions for the test specimens throughout the entire chamber volume.
As a result, the test results are accurate and repeatable.
Key Specifications
Temperature range: -40 °C to +160 °C.
Dkodpfozcpwpox Akmsu
Cooling system: Liquid nitrogen (LN2) for high cooling rates.
Temperature chamber for the AllroundLine
Application: Specifically designed for integration into material testing machines to perform mechanical tests (e.g., tensile or compression tests) under controlled environmental conditions.
All sheets in the door area (inside and outside) are made of stainless steel.
Solid base frame, demountable
Dimensions:
W x D x H = 1400 x 600 x 800 mm
Chamber:
W x D x H = 440 x 530 x 650 mm
Test opening: 110 mm
Power supply: 400/230 16A 3N〜50/60Hz
Cooling via LN2 (liquid nitrogen)
"Everything from a single source: We would be happy to offer you a suitable financing option for your project."
You can find more items – new and used – in our shop!
International shipping costs on request!
Success:
Your message has been sent.
Listing
Borken
7,623 km
Test chamber for temperature and vibration test system
ThermotronAST-18 AST 8800 HALT HASS
Call
Condition: used, Thermotron AST-18 HALT/HASS Test Chamber
Manufacturer: Thermotron Industries
Model: AST-18
Controller: AST-8800
Machine Type: HALT/HASS Test Chamber / Accelerated Stress Test System
For sale is a Thermotron AST-18 HALT/HASS test system for combined temperature and repetitive shock/vibration testing.
The system enables accelerated stress testing of components and assemblies through extreme temperature changes in combination with multi-axis vibration excitation. Operation and monitoring are performed via the Thermotron AST-8800 controller.
Technical Data:
Temperature Range: -100 to +200 °C
Temperature Change Rate: >50 °C/min at the test specimen
Vibration Frequency: 0 to >10,000 Hz
Vibration Axes: 3 linear + 3 rotational / 6 degrees of freedom
Max. Payload Test Table: 135 kg
Airflow Rate: 1,400 CFM / approx. 2,379 m³/h
Grid Dimension: approx. 102 × 102 mm
Voltage Supply: 400 V / 3 Ph / 50 Hz
Max. Current according to Nameplate: 65.3 A
Heating Power according to Nameplate: 20 kW
AST-8800 Controller:
Windows-based user interface
Combined temperature and vibration display
PSD / Power Spectral Density
Data recording and data storage
Vibration alarm and shutdown limits
Ethernet / Web access
User management
Monitoring of operating and maintenance times
Test Chamber:
W × D × H: approx. 838 × 864 × 762 mm
Test Chamber Volume: approx. 0.55 m³ / 550 liters
Vibration Table:
Manufacturer's table size depending on the configuration:
approx. 610 × 610 to 711 × 711 mm
Impactors: 4 or 5, depending on the design
Dimensions:
Move-In Dimensions W × D × H:
approx. 2,286 × 1,448 × 2,210 mm
Footprint: approx. 2.29 × 1.45 m
Equipment:
Thermotron AST-8800 controller
Repetitive shock/vibration table
Temperature test chamber
Acceleration sensors
Temperature measurement technology
Safety and monitoring functions
Condition:
Used
Optical condition as shown in the pictures.
Calibration valid until 30.11.2024, currently expired.
Dkjdpfezyndbjx Akmeu
Scope of Delivery:
Thermotron AST-18 HALT/HASS test system
AST-8800 controller
RS-28 unit
Scope of delivery and accessories as shown in the pictures.
Shipping Data:
Dimensions: approx. 2,286 × 1,448 × 2,210 mm
Weight: approx. 1,000 kg (estimated)
Shipping via freight forwarder possible.
Availability: upon agreement.
Subject to changes, errors and prior sale.
Success:
Your message has been sent.
Listing
Borken
7,614 km
Feutron TPK 3403/125 temperature test chamber -40 to +100°C temperature test cabinet
FeutronTPK 3403/125
Call
Condition: good (used), Feutron Temperature Testing Chamber -40 to +100°C
The Feutron TPK 3403/125, thanks to its robust design, is a reliable workhorse for standardized temperature tests.
The main application areas for this model are:
1. Electronics and Component Testing
This is the most common application. It involves testing how components react to extreme temperatures:
Functional testing: Does the circuit board still function flawlessly at -40 °C or +150 °C?
Burn-in tests: Artificial aging of components through continuous operation at high temperatures to provoke early failures.
2. Material Testing
Investigation of physical changes in materials:
Brittleness: Do plastics or rubber seals become brittle in the cold?
Deformation: Do composite materials warp in the heat?
Storage tests: How stable do chemical substances or adhesives remain over long periods at a constant temperature?
3. Quality Assurance (QA)
Sample testing: Tests carried out during production to ensure that the production process meets the specified temperature ranges.
Standard testing: Conducting tests according to common industry standards (e.g., DIN EN 60068), which prescribe specific temperature profiles.
4. Research & Development
Prototyping: Testing new housing designs or materials under controlled thermal conditions before mass production.
Manufacturer: Feutron
Type: TPK 3403/125
Temperature range: -40 to +100°C
Dkedpfx Akjy Nynasmeu
Refrigeration unit: Air-cooled condenser
Temperature stability: approx. ±0.1 to ±0.5 K
Usable volume: approx. 125 liters
Refrigerant: R22
Operating overpressure: 23 bar
Power connection: 220/280V-3-50Hz
Supply line fuse: 25 A
Protection class: IP 20
Weight: 480 kg
"Everything from a single source: We would be happy to offer you suitable bank financing for your project."
More items – new and used – can be found in our shop!
International shipping costs upon request!
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature test chamber, explosion-proof
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Dkedpfx Akozd Rzwemsu
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature test chamber 1000 liters
CTST-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Temperature testing chamber T-55/1000 Li, water-cooled
Temperature range: -50°C to +100°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Rated current: 18 A
Compressor: TFH2511Z / TFH2511Z, refrigerant R404A/R23
The type designation of the CTS chamber series is as follows:
e.g., Type T -55/1000/Li
1) T means: Temperature
2) -55 means: lower temperature -55°C
3) 1000 means: 1000-liter test chamber volume
4) Li means: special equipment for
testing with lithium-ion batteries
Control:
32-bit controller
LCD control panel
Digital display of setpoint and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for customer-specific
control of the test item
Test chamber lighting:
energy-efficient, bright LED light strip mounted on the door
Insert rack:
Stainless steel, support surface 970 x 980 mm
Load per rack max. 35 kg
Total load with max. rack load 100 kg
1a Conduit NW50
1b Conduit 2x NW125
1c Conduit 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Thermal compensation
approx. 4000 W at +20°C
Dksdpfx Akezg Ty Uomsu
approx. 2200 W at -40°C
The technical data refer to an ambient temperature of +25°C,
rated voltage 400V, without test item, without thermal compensation and without additional equipment.
Options can affect the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, Width, approx. 860 mm, Depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, Width, approx. 1270 mm, Depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(measured according to DIN EN ISO 3744
at a distance of 1 m from the front)
Weight approx. 1000 kg
Heat dissipation to the installation room 10.4 kW
Refrigeration unit:
water-cooled, low-noise, fully hermetic
stepless power adjustment by electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
For your safety as a buyer, the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerants
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have on the phone.
Success:
Your message has been sent.
Listing
Borken
7,614 km
Weiss SD 1400/+20 DU climate test chamber with seat pulsator, 20 - 100 °C heating chamber, humidity
WeissSD 1400/+20 DU
Call
Condition: good (used), Weiss climate testing chamber with seat pulsator
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test chamber:
Material: Stainless steel
Dimensions:
Djdpfexbgrgjx Akmsku
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Volume: 1440 liters
Outer housing
Material: Double-coated Zincor sheet
Dimensions:
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
H x W x D 2000 x 2200 x 2000 mm
Paint finish: Light grey (RAL 9002)
Door, double-leaf: Hinged on the left and right
Equipment:
Pass-through in the floor and ceiling: 2 each, DN 100 mm, for inserting the pulsation tables
Pass-through in the side walls: 1 each, left, right, 100 mm
Refrigeration unit: Air-cooled
Control: Digital measurement and control system DMR
Basic control panel: Integrated into the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS-Windows
Performance data:
Temperature range without climate control: +20...+100 °C
Temperature stability without climate control: +0.2 … +0.5 K (time-dependent) depending on the range, in the steady state
Temperature range with climate control: 20...+95 °C
Temperature stability with climate control: +0.2 … +0.5 K (time-dependent) depending on the range, in the steady state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH, depending on the range, in the steady state
Temperature change rate measured in the outlet without a test specimen and without a load
- Cooling: 0.5 K/min. on average, between +100 and +20 °C
- Heating: 0.5 K/min. on average, between +20 and +100 °C
The performance data refer to an ambient temperature of max. +25 °C and the specified rated voltage
For trouble-free operation of the system, the ambient temperature must be between +10 and +35 °C
Connections / Other
Protection class: IP 32 for the control cabinet
Sound pressure level during free-field measurement at a distance of 1 m in front of the device: 60 dB (A)
Humidification water: fully demineralized, conductivity max. 20 μS/cm, pH value 6 - 7, automatic topping up
Condensate drain: back-pressure-free, 3/4" hose connection
Power connection: 400 V; 3 PH+N PE; 50 Hz
Connected load: max. 10 KVA
Weight: approx. 1160 kg
Seat testing device with steel structure for mounting and securing to the climate testing chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for test specimen change, 12 weights each weighing 5 kg
• 1 base frame in normal steel welded construction for attachment to the underside of the climate testing chamber. This frame is provided on all sides with removable sheets and has 2 folding doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric disks with bearings and tachometer, 2 connecting rods, 2 ball guides
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for connecting the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for connecting the buttocks replica
• 2 load rods, 600 mm long, made of stainless steel (The connection to the test specimen is not included in our price, but can be offered subsequently after a precise definition)
• 2 three-phase motors, 2 belt drives with tensioning devices
• 1 pneumatic control system with 2 manual valves, one filter-regulator unit and one shut-off valve, 1 electrical control cabinet with 2 SEW frequency inverters, hand switch, emergency stop button, 2 push buttons,
Success:
Your message has been sent.
Listing
Schweinfurt
7,931 km
Vibration test system with climate chamber
ETS SolutionsMPA102/L620M
Call
Condition: used, ETS MPA102/L620M Shaker Vibration Testing & Horstmann HS 220 Climate Test Chamber System
Vibration Testing System: ETS MPA102/L620M
Sine Force: 600 kgf
Random Force: 600 kgf
Shock Force (6 ms, half sine): 1,200 kgf
Dkedpfjy Sl Uqjx Akmju
Max. Sine Velocity: 2 m/s
Max. Sine Acceleration: 981 m/s²
Armature Diameter: 200 mm
First Resonance Frequency: 3,300 Hz
Dimensions: 943 x 633 x 770 mm
Shaker Weight: 730 kg
Amplifier Unit: 6 kVA
Blower Unit: HP-2 / 4 kW
Climate Chamber: Horstmann HS220
Test Chamber Volume: 220 liters
Test Chamber Dimensions: 600 x 600 x 600 mm (H x W x D)
Temperature Range: -40 to +180 °C
Cooling Rate: 2 K/min
3 K/min
Heating Rate: 3 K/min
3 K/min
Electrical Connection: 400V, 3/N, 50 Hz / 5 kW
External Dimensions: 1,630 x 1,700 x 1,200 mm (H x W x D)
Used item as shown in the pictures.
Shipping:
The specified shipping costs apply to deliveries within Germany.
Worldwide shipping available (please inquire for shipping costs outside Germany).
The given shipping costs apply to shipping within Germany.
Sale only to commercial customers. No warranty or guarantee.
Deviations from the technical data as well as errors in the article description are possible and subject to change.
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature test chamber -75 to +150 °C
Feutron3416/16-Ex TPK 200
Call
Condition: excellent (used), eutron 3416/16-Ex TPK 200 Temperature Test Chamber
Manufacturer: Feutron Klimasimulation GmbH
Type: 3416/16-Ex
Series: TPK 200
Year of Construction: 2006
Machine Type: Temperature Test Chamber / Climate Simulation Chamber
Test Chamber Volume: 280 liters
For sale is a used Feutron 3416/16-Ex temperature test chamber with programmable control.
The system was developed for professional temperature tests,
environmental simulation, and material and component testing,
and is particularly suitable for testing laboratories, electronics,
research and development, and quality assurance.
Technical Data:
Model: 3416/16-Ex
Series: TPK 200
Year of Construction: 2006
Operating Hours: 59,655 h
Test Chamber Volume: 280 liters
Temperature Range: -75 °C to +150 °C
Temperature Deviation (over time): ≤ ±0.5 K
Temperature Change (Heating): up to approximately 3.0 K/min on average
Temperature Change (Cooling): up to approximately 1.0 K/min on average
Test Chamber Material: Stainless steel, material no. 1.4301
Test Chamber Insulation: CFC-free multi-layer insulation
Refrigeration System:
Design: Water-cooled, semi-hermetic cascade system
Refrigerant 1: R507
Refrigerant Quantity: 2.5 kg
Refrigerant 2: R23
Refrigerant Quantity: 0.5 kg
Continuous Sound Pressure Level: approximately 67 dB(A)
Cooling Water:
Cooling Water Pressure: min. approximately 2.0 bar / max. 6.0 bar
Max. Cooling Water Temperature (Inlet): approximately 18 °C
Cooling Water Temperature (Outlet): approximately 30 °C
Average Cooling Water Consumption: approximately 0.3 m³/h
Electrical Data:
Supply: 400 V / 3/N/PE AC / 50 Hz
Power Plug: CEE 5-pin, 16 A
Max. Simultaneous Power Consumption: 5.6 kW
Fuse Rating: 3 × 16 A, characteristic C
Protection Class: IP20
Dimensions:
External Dimensions (W × D × H): approximately 1,500 × 1,075 × 2,140 mm
Min. Installation Dimensions: approximately 1,500 × 995 × 1,960 mm
Installation Dimensions with Doors Open (W × D × H): approximately 2,400 × 1,990 × 2,140 mm
Weight: approximately 680 kg
Equipment:
Programmable Feutron Controller
LCD Display
Program and manual operation
Up to 20 programs can be stored
RS-232 interface
3 stainless steel grids
Test chamber lighting
Observation window
1 × feedthrough Ø 75 mm with cover cap
Dodpjz Hl Dvsfx Akmeku
2 × feedthrough Ø 75 mm on the side
1 × feedthrough Ø 100 mm on the side
Compressed air connection
Cooling water supply and return
Additional temperature controller
Accessories according to images
Transport Data:
Device (W × D × H): approximately 1,500 × 1,075 × 2,140 mm
Weight: approximately 680 kg
Min. Installation Dimensions after Dismantling Corresponding Components: approximately 1,500 × 995 × 1,960 mm
Condition:
Used
Device starts up.
Controller and display are active.
Optical condition according to images.
Scope of Delivery:
Feutron 3416/16-Ex TPK 200 Temperature Test Chamber
3 stainless steel grids
Fan / Accessories according to images
Documentation according to images
Availability: by arrangement.
Scope of delivery as shown in the images.
Subject to change, errors and prior sale.
Success:
Your message has been sent.
Listing
Darmstadt
7,848 km
Cycle test machine with temperature chamber
Dyna-MessTP 10 kN HF
Call
Year of construction: 2015, operating hours: 100 h, condition: excellent (used), functionality: fully functional, machine/vehicle number: 4S 10kN 2268/000 1215 902, Dyna-Mess TP 10kN HF Cyclic Testing Machine / Endurance Testing System – Top Condition, including temperature chamber (up to 120°C) & software
Description:
Manufacturer: DYNA-MESS Prüfsysteme GmbH
Model: TP 10kN HF (Servopneumatic High-Frequency Cyclic Testing Machine)
Dodpfx Akozunz Nomjku
Maximum test force: 10 kN (static and dynamic range)
Maximum machine travel: 12 mm
Date of purchase: December 2015
Condition: Almost new, very little use, immediately ready for operation (Plug & Play)
Availability: Immediately
For sale is a compact, high-precision cyclic testing machine from the premium manufacturer DYNA-MESS with a 10 kN nominal load and 12 mm stroke. The system was acquired for dynamic endurance tests and lifetime determination as part of a research project, and has not been used since. It is in excellent, virtually new condition both visually and technically.
The complete package includes a matching temperature chamber with controller up to 120°C. This enables standard-compliant, dynamic testing of components and materials under realistic thermal environmental conditions.
System & Scope of Supply:
Load frame Dyna-Mess TP 10kN HF with high-precision force and displacement sensors.
Complete PC including installed and calibrated control software DYNA-TCC under Windows 7. The system operates completely independently and is immediately ready for use.
Temperature chamber with external control unit for tests up to 120°C. All associated documentation and connection cables. The machine is perfectly suited for laboratories, universities, or quality assurance departments looking for a reliable system for fatigue and endurance testing without incurring the cost of a new machine. Inspection of the machine is possible by prior arrangement. As this is a commercial sale, the machine is sold ex works without warranty or guarantee. The sale is preferably to a buyer who arranges self-collection (dismantling and transport must be organized by the buyer).
Price: €20,000 negotiable plus VAT.
Success:
Your message has been sent.
Listing
Borken
7,614 km
Weiss SC 1000/+20IU Corrosion Climate Alternating Test Chamber, Salt Spray Test Chamber
WeissSC 1000/+20IU
Call
Condition: excellent (used), Weiss SC 1000/+20IU Corrosion Climate Cycle Test Chamber
Weiss SC 1000/+20 IU Corrosion Climate Cycle Test Chamber
The test system is a combination of a climate testing chamber with variable temperature and humidity and a corrosion testing chamber with a salt spray test.
In a time-lapse mode, vulnerable metallic components are tested for corrosion according to the relevant standards.
Temperature operating range:
Temperature: +20 °C ... +60 °C
Time-dependent temperature deviation: +0.5 K
Climate operating range:
Temperature: +20 °C ... +60 °C
Time-dependent temperature deviation: +0.5 K
Relative humidity: 10...98 % RH
Time-dependent humidity deviation: 3...5 % RH
Dew point: +12 °C ... +59 °C
Salt spray test SS (temperature range: ambient temperature +5 K ... +50 °C)
according to DIN 50 021 (salt spray with a two-nozzle system, 1.5 x 0.5 mV80 cm? h)
Control:
Digital measuring and control system SIMCON/32*-Net with touch panel
Interfaces: serial interface RS 232 C, parallel printer interface
Operating modes adjustable via process controller:
- Temperature control
- Climate control
- Salt spray test
- Direct spraying with salt solution
- Condensation load
- Flushing of test chamber walls
- Drying/ventilating the test chamber
Temperature sensor: Pt 100 resistance thermometer
Humidity sensor: psychrometric fresh measuring system tft’ (with forced humidification)
Technical data SC 1000/+20 JU
Usable space dimensions:
Height up to roof slope approx. 1000 mm
+ Roof approx. 350 mm
Width approx. 1100 mm
Width between the heaters approx. 1000 mm
Depth approx. 1000 mm
Test chamber door made of glass, left-hinged
Height approx. 1350 mm
Width approx. 1000 mm
External dimensions including unit components and control cabinet
Height approx. 2100 mm
Width approx. 1450 mm
Width with touch panel approx. 1700 mm
Depth approx. 2600 mm
Maximum floor load: 100 kg
Brine storage tank:
approx. 200 l, with level monitoring, located separately to the side/behind the unit
Height approx. 1000 mm
Width approx. 600 mm
Depth approx. 900 mm
Electrical connection: 400 V
Connected power: 13 kW
Weight: 1300 kg
You can find more items - new and used - in our shop!
Dkedpjph U Dhofx Akmou
International shipping costs on request!
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature shock test chamber
especTSD-100
Call
Condition: used, Espec
Type: TSD-100
100 liters usable chamber volume for larger test specimens up to 30 kg.
Compliant with all common international standards.
Water-cooled
Temperature range hot chamber: +60°C to +200°C
Temperature range cold chamber: -70°C to 0°C
Test chamber interior dimensions: 710 x 345 x 410 mm (W x H x D)
External dimensions: 1100 x 1885 x 1965 mm (W x H x D)
Water-cooled refrigeration unit
Programmable control via touch panel
Automatic defrosting
Overtemperature protection
Operating hours counter
Mobile design (on castors)
2 stainless steel specimen baskets
Cable entry port ⌀ 100 mm
Refrigerants: 3 kg R404A, 1 kg R23
Power supply: 400V 3Ph 50Hz
Max. current consumption: 32A
Condition: used
Weight: 1100 kg
Important safety information for buyers:
The following procedures are performed on all chambers offered by us prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
Dkedezizl Rspfx Akmju
4. Upon passing inspection, chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to modifications and errors in technical data and specifications!)
For further questions, please feel free to contact us by phone.
Success:
Your message has been sent.
Listing
Borken
7,614 km
Parker solar module test stand, solar cell testing module, photovoltaic module test chamber
Parker Hannifin GmbHVertical Light Stack Module
Call
Condition: like new (used), Year of construction: 2012, Parker Engineering & Design Vertical Light Stack Module
For testing solar modules and photovoltaic modules
Testing of electrical and mechanical safety
Support for product development, design, and quality control
Dkedpjh Rvh Sofx Akmsu
Early detection of potential problems during the development phase
Quality and safety control
Endurance testing stand
Temperature control
Mobile on rollers
Pockets for forklift access
400 VAC, 3-phase, 50 AMP
IR: 10,000 Amp
Year of manufacture: 2012
Weight: 1400 kg
Dimensions (H x W x D): 2900 x 1700 x 1900 mm
You can find more testing equipment – new and used – in our shop!
International shipping costs available upon request!
Success:
Your message has been sent.
Listing
Borken
7,623 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS Climate Test Chamber T-70/600 Water-Cooled
Temperature Range: -70°C to +180°C
Rated Voltage: 400V 3/N PE 50 Hz
Rated Power: 6.7 kW
Rated Current: 10.2 A
Compressor: TFH2480Z/TFH2511Z, Refrigerant R23/R404A
Dkodpfx Akeziycbsmju
Control System:
- Microprocessor-controlled regulation and monitoring system
- Simple, user-friendly terminal integrated into the door
- Digital display for set and actual temperature values
- Easy adjustment via +/- keys
- Digital input for temperature in °C
- PLC-compatible
- Up to 100 test programs possible
- RS 232 interface
- 2 free switching channels for user-side test specimen connections
Shelving:
Stainless steel, shelf area 820 x 710 mm
Load capacity per shelf max. 35 kg
Total load capacity with full shelf configuration 100 kg
Cooling Unit:
Water-cooled, low-noise, fully hermetic, stepless power adjustment via electronic monitoring and control system,
environmentally friendly refrigerants R404A/R23
Temperature Testing:
Temperature range -70°C to +180°C
Temperature deviation ±0.1 to 10.3 K over time
Temperature change rate according to DIN 50 011, Part 12 measured at the center of the test chamber:
Heating: 2.5 K/min
Cooling: 2 K/min
Thermal radiation max. 1500 W at +20°C
Technical data refer to an ambient temperature of +25°C, rated voltage 400 V, without test specimen, without thermal radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x D x H)
External dimensions 1050 x 1850 x 1900 mm (W x D x H)
Operating Data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current 10.2 A
Protection class IP 22
Condensate drain non-pressurized, R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information reserved!)
Further questions can be answered by phone.
Success:
Your message has been sent.
Listing
Borken
7,614 km
Weiss Temperature Test Chamber WT 11-18 KWP 500/40, 500 liters, -40°C to +180°C
WeissKWP 500/40
Call
Year of construction: 1990, condition: good (used), Weiss temperature test chamber WT 11-18 KWP 500/40
Spring, summer, autumn, and winter – your products must be able to withstand different temperatures during manufacturing, transport, storage, and use. The temperature test chambers from Weiss Technik help you to test the influence of thermal conditions on the properties, function, and service life of your products.
Manufacturer: Weiss Technik
Type: KWP 500/40 - 180 DU
Dksdpeh Izh Iefx Akmeu
Designation: WT 11-18
Type: Temperature test chamber
Test chamber volume: 500 liters
Temperature range: -40°C to +180°C
External dimensions: 110 cm wide, 173 cm deep, and 204 cm high
Internal dimensions: 80 cm wide, 85 cm deep, and 85 cm high
Pressure: 25 bar
Voltage: 380 V
Frequency: 50 Hz
kVA: 4.7
Refrigerant: R 502
Year of manufacture: 1990
Condition: used
Complete factory closure,
large selection of storage platforms, pallet racks, shelving systems, paternosters.
High-quality industrial machines, lathes, grinding machines, hand tools.
You can find more items – new and used – in our shop!
International shipping costs on request!
Trust Seal
Dealers certified through Used-Machines

Success:
Your message has been sent.
Listing
Borken
7,614 km
Vötsch VTSR 7034/S Climate Test Chamber -70 to +180°C Temperature Test Chamber TK11
VötschVTSR 7034/S
Call
Year of construction: 2002, condition: good (used), Vötsch VTSR 7034/S Climate Testing Chamber, -70 to +180°C
Manufacturer: Vötsch
Type: VTSR 7034/S
Test chamber volume: 335 liters
Climate testing chamber
Temperature range: -70 to +180°C
Supply voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated current: 22 A
Rated power: 12.5 kW
Dksdpfsuuif Nox Akmeu
Refrigerant (cooling): R 404 A
Refrigerant (heating): R 23
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Year of manufacture: 2002
TK-11
You can find more new and used items in our shop!
International shipping costs available upon request!
Success:
Your message has been sent.
Listing
El Prat de Llobregat
7,963 km
Regenerative Thermal Oxidizer
FLOW & THERMAL
Call
Year of construction: 2021, condition: ready for operation (used), functionality: fully functional, FLOW & THERMAL Regenerative Thermal Oxidizer (RTO), 18,000 Nm³/h (2021)
Complete industrial system for the treatment of process water containing Volatile Organic Compounds (VOCs), consisting of stripping columns and a three-chamber Regenerative Thermal Oxidizer.
Manufactured by Flow & Thermal Solutions / TECAM in 2021, the equipment was installed at a PET production plant and remained operational until the factory closed on 27 November 2025.
The system removes VOCs from the water by means of air stripping and subsequently destroys them in the RTO through high-temperature thermal oxidation. Heat recovery through ceramic media helps reduce natural gas consumption.
Main features
• Manufacturer: Flow & Thermal Solutions / TECAM
• Year: 2021
• Serial number: F002
• RTO nominal capacity: 18,000 Nm³/h
• Configuration: three-chamber regenerative RTO
• Fuel: natural gas
• Honeywell / Eclipse TJ 200 burner
• Burner output: 58–586 kW
• Electrical supply: 400 V, 50 Hz
• Electrical power stated on the nameplate: 40 kW
• 30 kW Soler & Palau ATEX main fan
• Siemens PLC automation with HMI touchscreen
• LEL monitoring, purge, dilution, bypass and pneumatic valve systems
• Vertical stack: 10 m high, diameter: 800 mm
• CE marked
Performance and operation
The equipment operated at actual flow rates close to its nominal capacity, with recorded values ranging from approximately 16,400 to 17,900 Nm³/h.
The latest available emissions test, carried out by DEKRA in December 2023, recorded the following values:
• TOC: 13 mgC/Nm³
• NOx: 3–4 mg/Nm³
• CO: 125–153 mg/Nm³
During the tests, the equipment operated at an approximate temperature of 775–780 °C, with a treated water flow rate of 3.5 m³/h.
Stripping columns
The system includes:
• Original stripping column, designed for approximately 6 m³/h.
• Second Tecnium SLFKK9 stripping column, manufactured in PPH, with a nominal capacity of 8 m³/h and a maximum capacity of 10 m³/h.
The second column was installed, but it is currently dismantled and lying on the ground after being knocked down by strong winds during the winter. It has a hole in the base which, according to the available information, is considered potentially repairable.
The Tecnium column is equipped with internal packing, distributors, a mist eliminator, connections, drainage and provisions for integration with the existing control system.
Condition and maintenance
The system remained operational until the final closure of the plant in November 2025.
The latest preventive maintenance was carried out by TECAM in June 2025 and included mechanical and electrical inspection, burner, fans, stripping columns, instrumentation, valves and functional testing.
The equipment was operational, although maintenance work is required before recommissioning, mainly involving:
• Process valves
• Internal insulation of the towers
• Ductwork and seals
• Main fan impeller and expansion joints
• Repair of the base of the second stripping column
Dsdpfx Akjzvcknomsku
TECAM technical documentation is available regarding the recommended works, and several spare parts are also available.
Scope of supply
The system includes:
• Three-chamber RTO
• Combustion chamber
• Burner and gas train
• Main fan
• Two stripping columns
• Dilution and purge system
• Hot bypass
• LEL analysers
• Stack
• Ductwork
• Electrical cabinets and controls
• Platforms, ladders and support structures
• Available spare parts
Success:
Your message has been sent.
Listing
Borken
7,614 km
Vötsch VTR 7033/S Temperature Test Chamber -70°C to +180°C Climate Test Chamber TK07
VötschVTR 7033/S
Call
Condition: good (used), Year of construction: 1996, Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature chamber
Temperature range: -70°C to +180°C
Supply voltage: 400V
Rated current: 24A
Rated power: 9.5 kW
Refrigerant (high-temperature): R 404 A
Refrigerant (low-temperature): R 23
Year of manufacture: 1996
TK 07
Dkjdpfjwbpzmex Akmeu
You can find more new and used items in our shop!
International shipping costs available upon request!
Success:
Your message has been sent.
Listing
Borken
7,614 km
Vötsch VTR 7033/S Temperature Test Chamber -70°C to +180°C Climate Test Chamber TK09
VötschVTR 7033/S
Call
Year of construction: 1998, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Article No.: 60885637
Temperature chamber
Temperature range: -70°C to +180°C
Supply voltage: 400V
Rated current: 24A
Rated power: 9.5 kW
Refrigerant (refrigeration): R 404 A
Refrigerant (low-temperature): R 23
Year of manufacture: 1998
Dksdpfsuuin Rox Akmeu
Chamber: W x D x H 670 x 640 x 750 mm
TK 09
You can find more new and used items in our shop! International shipping costs available upon request!
We make it easier for you to find: "rs-simulatoren thermal shock test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time




























































































































































































































































